首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
目的建立氢化物发生-原子荧光光谱法同时测定尿中砷和汞[1]的方法。方法尿样经微波消解消化处理后,用氢化物发生双通道原子荧光光谱法同时测定尿中砷和汞的浓度。结果本方法中砷和汞的浓度分别在(0.00-100.0)μg/L和(0.00-80.0)μg/L的范围内有良好的线性关系,相关系数分别为r As=0.999 5和r Hg=0.999 2,方法检出限分别为As:0.28μg/L、Hg:0.045μg/L,相对标准偏差分别为0.44%~1.82%、1.11%~2.36%,回收率分别在95.50%~99.52%和94.70%~102.0%之间。结论用该法同时测定尿中砷和汞是准确可靠、操作简便、快捷、可行的,适合职业体检等大批量样本的检测分析。  相似文献   

2.
[目的]应用AFS-2202E型双道原子荧光光度计测定生活饮用水中的汞。[方法]以1 9硝酸为载流,0.5g/L硼氢化钾为还原剂,将汞还原为原子态,以氩气为载气将汞引入原子化器,经汞空心阴极灯光源激发,产生共振荧光,荧光强度与汞浓度遵守朗伯—比耳定律,求出汞含量。[结果]汞在0.50~10.00μg/L范围内,荧光强度值与汞浓度相关系数r>0.999,汞的最低检出限DL=0.0411μg/L,RSD=1.957%,回收率88%~106%。[结论]应用原子荧光法测定生活饮用水中汞,操作简便,检出限低,重现性好,线性关系好,回收率高,适用于生活饮用水中微量汞的测定。  相似文献   

3.
微波消化原子荧光光谱法同时测定食品中镉和汞   总被引:1,自引:0,他引:1  
[目的]建立原子荧光光谱法同时测定食品中镉和汞的方法。[方法]以硝酸-过氧化氢作氧化剂,微波消解食品样品后,用原子荧光光谱法同时测定样品中的镉和汞。优化了食品样品处理和原子荧光光谱检测的实验条件,同时对共存干扰元素的影响和消除进行研究。[结果]在优化的条件下,镉、汞分别在0.2~4.0μg/L范围内呈良好的线性关系(相关系数为镉0.9999、汞0.9994)。该方法的检出限镉为0.007μg/L、汞为0.032μg/L,镉和汞的定量限分别为0.022μg/L和0.105μg/L。测定的相对标准偏差(RSD)镉为1.65%~4.8%、汞为1.0%~5.1%。加标回收率分别为镉97.0%~119.5%、汞88.5%~104.0%。[结论]该方法灵敏度高、准确性好,快速简便,适用于食品样品中镉和汞的同时测定。  相似文献   

4.
[目的]对原来研制的尿汞标准分析方法做进一步研究,建立尿中汞的还原气化-原子吸收光谱法分析的新方法。[方法]尿样中汞(尿中无机汞和经溴酸钾-溴化钾处理尿中有机汞生成的无机汞之和)以硼氢化钠还原生成汞原子蒸气,用原子吸收光谱仪测定其汞的含量。采用正交设计探讨最佳实验条件,并与原法做比较。[结果]本法的最佳实验条件为盐酸溶液浓度5%(v/v),硼氢化钠溶液和溴化剂的用量各为2ml,载气流量0.6L/min。其尿汞线性范围在0~24μg/L,线性相关系数测定为0.9997,检测限为0.014μg/L,精密度测定相对标准偏差为0.87%~6.67%,加标回收率测定为95.81%~98.61%。本方法与原法比较,标准曲线值呈高度相关,尿汞测定值无明显差别。[结论]经改进后的方法测定尿汞与原法比较有同样的效果,并且更加实用,利于推广。  相似文献   

5.
双道原子荧光光度计同时测定化妆品中砷和汞   总被引:1,自引:0,他引:1  
[目的]建立双道原子荧光光谱法同时测定化妆品中汞、砷的方法。[方法]采用微波消解样品预处理技术原子荧光光谱法同时测定化妆品汞、砷的含量。[结果]汞、砷的含量分别在0.0~2.0μg/L、0.0~20.0μg/L的范围内,相关系数分别为0.9992、0.9998,检出限分别为0.0022、0.018μg/L,相对标准偏差分别为6.67%、3.24%,回收率分别在97.3%、101%之间。[结论]微波消解-双道原子荧光光光谱法同时测定化妆品中的汞和砷是可行的。  相似文献   

6.
微波消解—双道原子荧光光谱法同时测定水产品中砷和汞   总被引:2,自引:0,他引:2  
目的:建立微波消解—原子荧光光谱法同时测定水产品中砷和汞的方法。方法:采用微波消解方法,双道原子荧光光谱法同时测定水产品中砷和汞的含量。结果:砷与汞的线性范围分别为0.04~200μg/L,0.01~100μg/L;相关系数分别为r=0.9998,r=0.9999;砷回收率为95.7%~98.4%,相对标准偏差为1.75%~3.41%,检出限为0.04μg/L;汞回收率为92.5%~97.9%,相对标准偏差为1.77%~2.77%,检出限为0.01μg/L。结论:微波消解—双道原子荧光光谱法测定水产品中砷和汞,方法灵敏度高,操作简便快速,结果准确可靠。  相似文献   

7.
采用冷消解样品预处理技术和原子荧光光谱法同时测定尿中汞、砷的含量。该方法汞和砷的线性范围分别为0.0~7.5μg/L和0.0~30.0μg/L,检出限分别为0.087μg/L和0.48μg/L,相对标准偏差分别为2.44%~5.88%、3.32%~4.42%,回收率分别在103.5%~114.0%和96.7%~115.0%之间。  相似文献   

8.
[目的]通过测定蛋制品中的汞,研究了氢化物发生测定汞的最佳条件。[方法]利用流动注射氢化物发生技术与原子吸收分光光度计相结合的方法测定汞,并和国家标准冷原子吸收光谱法进行了实验比对。[结果]本法检出限为0.10μg/L,相对标准偏差在3.7%~6.1%之间,回收率范围在96.9%~104.2%之间,平均回收率为100.3%,结果令人满意。[结论]本方法简便、重现性好、准确度高、灵敏度好,适用于条件有限的基层单位。  相似文献   

9.
[目的]建立同时测定尿中硒、汞的方法。[方法]利用氢化物发生—原子荧光及微波消解技术同时测定尿中的硒和汞。[结果]该方法测得尿中中硒、汞的最低检出限分别为0.0450、0.0098μg/L,相对标准偏差分别为3.45%、3.08%。[结论]该方法适用于尿中硒和汞的测定。  相似文献   

10.
[目的]建立水中镉和汞的蒸气发生原子荧光光谱同时测定方法。[方法]对镉和汞的蒸气发生条件以及原子荧光光谱同时测定镉和汞的各参数条件进行研究。[结果]在最佳测试条件下,镉方法检出限为0.03μg/L,测定相对标准偏差为1.1%~3.4%,样品加标回收率为98.6%~105%。汞方法检出限为0.0075μg/L,测定相对标准偏差为0.68%~3.2%,样品加标回收率为102%~107%。[结论]该方法灵敏度高、精密度好、操作简便快速,适于水中镉和汞的同时测定。  相似文献   

11.
12.
文章分析了当前医院护理管理队伍存在的主要问题:知识结构不合理;专业思想不纯正;接受继续教育不足:工作效能低下。提出了建设高素质护理管理人才队伍的思路:严格标准,搞好选才;加强思想教育和引导;加大培养力度;建立科学考评和激励机制;完善人才合理流动措施;合理编制,突出效率。  相似文献   

13.
14.
15.
16.
17.
BACKGROUND: This study examines the prevalence and correlates of stages of change of smoking, in terms of psychosocial, structural and sociodemographic factors, among inhabitants of deprived neighbourhoods. METHODS: Cross-sectional data were obtained from a survey on health related behaviour. Subjects were 2009 current and former smokers, aged 20-46, living in deprived neighbourhoods in Rotterdam, the second largest city in the Netherlands. Three groups of smokers were formed according to the stages of change-definitions of the Transtheoretical Model: smokers not planning to quit (precontemplators), smokers planning to quit (contemplators/preparators) and former smokers (actors/maintainers). Smokers planning to quit and smokers not planning to quit were compared regarding psychosocial factors (attitude, social norm, self-efficacy), structural factors (neighbourhood problems, material deprivation, financial problems, employment status) and sociodemographic factors (age, gender, marital status, cultural background, educational level). Former smokers were compared with smokers planning to quit regarding structural and sociodemographic factors. Logistic regression was used to assess correlates of stages of change. RESULTS: Smokers planning to quit (prevalence = 19%) reported a more positive attitude, stronger social norms and higher self-efficacy expectations in quitting smoking than smokers not planning to quit (prevalence = 57%). Smokers planning to quit less often were Dutch-born, more often had attended higher vocational schooling or university and more often reported experiencing two or more neighbourhood problems compared to smokers not planning to quit. Former smokers (prevalence = 24%) were older, more often Dutch-born, married, employed and higher educated, compared to smokers planning to quit. Furthermore, former smokers less often reported material deprivation and financial problems than smokers planning to quit. CONCLUSION: Among people living in deprived neighbourhoods, different factors correlate with different stages of change of smoking. Implications for health promotion are discussed.  相似文献   

18.
风险防范机制的缺失是阻碍转基因食品产业发展的因素之一。基于转基因食品产业对人类健康、物种进化和生态环境的负面影响,及时有效地构建风险防范机制十分必要。我国既有的转基因食品产业风险防范机制存在诸多缺陷:未形成转基因食品全程跟踪制度及安全事故应急处理制度,在安全性评价制度及法律责任体系等方面也有待进一步完善。  相似文献   

19.
目的 观察中药干预不同程度产后抑郁症患者的临床疗效.方法 选择90例产后抑郁症患者,随机平均分为干预组和对照组,每组中又平均各自分为轻度、中度、重度3组.干预组在基础治疗上加中药干预治疗,对照组只进行基础治疗.结果 两组轻度产后抑郁症患者均100%痊愈;中度产后抑郁症患者,痊愈率和有效率差异无统计学意义(P>0.05);重度产后抑郁症患者中,干预组的痊愈率和有效率均显著高于对照组(P<0.05).结论 中药干预重度产后抑郁症患者具有一定的疗效.  相似文献   

20.
医学科技成果信息资源网络开放利用,为资源的开放共享创造了良好条件,它使医学科技信息得到了高效传播和最大利用。网络开放利用医学科技成果信息资源,利用的主体和核心是其信息内容。信息内容是网络用户从中提取知识和所需资料的主要来源,同时也是信息破坏者发动攻击的主要目标之一,因而,信息内容的安全是信息安全的基本问题,主要包括信息内容的规范性、完整性与真实性、知识产权保护与利用的合理性等。要做好这些工作,应该遵循相应的原则和要求。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号