首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
• Effects of metabolic uncoupler TCS on the performances of GDMBR were evaluated. • Sludge EPS reduced and transformed into dissolved SMP when TCS was added. • Appropriate TCS increased the permeability and reduced cake layer fouling. • High dosage aggravated fouling due to compact cake layer with low bio-activity. The gravity-driven membrane bioreactor (MBR)system is promising for decentralized sewage treatment because of its low energy consumption and maintenance requirements. However, the growing sludge not only increases membrane fouling, but also augments operational complexities (sludge discharge). We added the metabolic uncoupler 3,3′,4′,5-tetrachlorosalicylanilide (TCS) to the system to deal with the mentioned issues. Based on the results, TCS addition effectively decreased sludge ATP and sludge yield (reduced by 50%). Extracellular polymeric substances (EPS; proteins and polysaccharides) decreased with the addition of TCS and were transformed into dissolved soluble microbial products (SMPs) in the bulk solution, leading to the break of sludge flocs into small fragments. Permeability was increased by more than two times, reaching 60–70 L/m2/h bar when 10–30 mg/L TCS were added, because of the reduced suspended sludge and the formation of a thin cake layer with low EPS levels. Resistance analyses confirmed that appropriate dosages of TCS primarily decreased the cake layer and hydraulically reversible resistances. Permeability decreased at high dosage (50 mg/L) due to the release of excess sludge fragments and SMP into the supernatant, with a thin but more compact fouling layer with low bioactivity developing on the membrane surface, causing higher cake layer and pore blocking resistances. Our study provides a fundamental understanding of how a metabolic uncoupler affects the sludge and bio-fouling layers at different dosages, with practical relevance for in situ sludge reduction and membrane fouling alleviation in MBR systems.  相似文献   

2.
• Annual AOCs in MBR effluents were stable with small increase in warmer seasons. • Significant increase in AOC levels of tertiary effluents were observed. • Coagulation in prior to ozonation can reduce AOC formation in tertiary treatment. • ∆UV254 and SUVA can be surrogates to predict the AOC changes during ozonation. As water reuse development has increased, biological stability issues associated with reclaimed water have gained attention. This study evaluated assimilable organic carbon (AOC) in effluents from a full-scale membrane biological reactor (MBR) plant and found that they were generally stable over one year (125–216 µg/L), with slight increases in warmer seasons. After additional tertiary treatments, the largest increases in absolute and specific AOCs were detected during ozonation, followed by coagulation-ozonation and coagulation. Moreover, UV254 absorbance is known to be an effective surrogate to predict the AOC changes during ozonation. Applying coagulation prior to ozonation of MBR effluents for removal of large molecules was found to reduce the AOC formation compared with ozonation treatment alone. Finally, the results revealed that attention should be paid to seasonal variations in influent and organic fraction changes during treatment to enable sustainable water reuse.  相似文献   

3.
• Bacteria could easily and quickly attached onto TEP to form protobiofilms. • TEP-protobiofilm facilitate the transport of bacteria to membrane surface. • More significant flux decline was observed in the presence of TEP-protobiofilms. • Membrane fouling shows higher sensitivity to protobiofilm not to bacteria level. Transparent exopolymer particles (TEPs) are a class of transparent gel-like polysaccharides, which have been widely detected in almost every kind of feed water to membrane systems, including freshwater, seawater and wastewater. Although TEP have been thought to be related to the membrane fouling, little information is currently available for their influential mechanisms and the pertinence to biofouling development. The present study, thus, aims to explore the impact of TEPs on biofouling development during ultrafiltration. TEP samples were inoculated with bacteria for several hours before filtration and the formation of “protobiofilm” (pre-colonized TEP by bacteria) was examined and its influence on biofouling was determined. It was observed that the bacteria can easily and quickly attach onto TEPs and form protobiofilms. Ultrafiltration experiments further revealed that TEP-protobiofilms served as carriers which facilitated and accelerated transport of bacteria to membrane surface, leading to rapid development of biofouling on the ultrafiltration membrane surfaces. Moreover, compared to the feed water containing independent bacteria and TEPs, more flux decline was observed with TEP-protobiofilms. Consequently, it appeared from this study that TEP-protobiofilms play a vital role in the development of membrane biofouling, but unfortunately, this phenomenon has been often overlooked in the literature. Obviously, these findings in turn may also challenge the current understanding of organic fouling and biofouling as membrane fouling caused by TEP-protobiofilm is a combination of both. It is expected that this study might promote further research in general membrane fouling mechanisms and the development of an effective mitigation strategy.  相似文献   

4.
• Retrofitting from CAS to MBR increased effluent quality and environmental benefits. • Retrofitting from CAS to MBR increased energy consumption but not operating cost. • Retrofitting from CAS to MBR increased the net profit and cost efficiency. • The advantage of MBR is related to the adopted effluent standard. • The techno-economy of MBR improves with stricter effluent standards. While a growing number of wastewater treatment plants (WWTPs) are being retrofitted from the conventional activated sludge (CAS) process to the membrane bioreactor (MBR) process, the debate on the techno-economy of MBR vs. CAS has continued and calls for a thorough assessment based on techno-economic valuation. In this study, we analyzed the operating data of 20 large-scale WWTPs (capacity≥10000 m3/d) and compared their techno-economy before and after the retrofitting from CAS to MBR. Through cost-benefit analysis, we evaluated the net profit by subtracting the operating cost from the environmental benefit (estimated by the shadow price of pollutant removal and water reclamation). After the retrofitting, the removal rate of pollutants increased (e.g., from 89.0% to 93.3% on average for NH3-N), the average energy consumption increased from 0.40 to 0.57 kWh/m3, but the operating cost did not increase significantly. The average marginal environmental benefit increased remarkably (from 0.47 to 0.66 CNY/g for NH3-N removal), leading to an increase in the average net profit from 19.4 to 24.4 CNY/m3. We further scored the technical efficiencies via data envelopment analysis based on non-radial directional distance functions. After the retrofitting, the relative cost efficiency increased from 0.70 to 0.73 (the theoretical maximum is 1), while the relative energy efficiency did not change significantly. The techno-economy is closely related to the effluent standard adopted, particularly when truncating the extra benefit of pollutant removal beyond the standard in economic modeling. The modeling results suggested that MBR is more profitable than CAS given stricter effluent standards.  相似文献   

5.
• A pilot study was conducted for drinking water treatment using loose NF membranes. • The membranes had very high rejection of NOM and medium rejection of Ca2+/Mg2+. • Organic fouling was dominant and contribution of inorganic fouling was substantial. • Both organic and inorganic fouling had spatial non-uniformity on membrane surface. • Applying EDTA at basic conditions was effective in removing membrane fouling. Nanofiltration (NF) using loose membranes has a high application potential for advanced treatment of drinking water by selectively removing contaminants from the water, while membrane fouling remains one of the biggest problems of the process. This paper reported a seven-month pilot study of using a loose NF membrane to treat a sand filtration effluent which had a relatively high turbidity (~0.4 NTU) and high concentrations of organic matter (up to 5 mg/L as TOC), hardness and sulfate. Results showed that the membrane demonstrated a high rejection of TOC (by>90%) and a moderately high rejection of two pesticides (54%–82%) while a moderate rejection of both calcium and magnesium (~45%) and a low rejection of total dissolved solids (~27%). The membrane elements suffered from severe membrane fouling, with the membrane permeance decreased by 70% after 85 days operation. The membrane fouling was dominated by organic fouling, while biological fouling was moderate. Inorganic fouling was mainly caused by deposition of aluminum-bearing substances. Though inorganic foulants were minor contents on membrane, their contribution to overall membrane fouling was substantial. Membrane fouling was not uniform on membrane. While contents of organic and inorganic foulants were the highest at the inlet and outlet region, respectively, the severity of membrane fouling increased from the inlet to the outlet region of membrane element with a difference higher than 30%. While alkaline cleaning was not effective in removing the membrane foulants, the use of ethylenediamine tetraacetate (EDTA) at alkaline conditions could effectively restore the membrane permeance.  相似文献   

6.
• A stable and electroconductive CNTs/ceramic membrane was fabricated. • The membrane with the electro-assistance exhibited optimal fouling mitigation. • The removal efficiency was improved by the -2.0 V electro-assistance. • Electro-assisted filtration is energy-saving than that of commercial membrane. Ultrafiltration is employed as an important process for water treatment and reuse, which is of great significance to alleviate the shortage of water resources. However, it suffers from severe membrane fouling and the trade-off between selectivity and permeability. In this work, a CNTs/ceramic flat sheet ultrafiltration membrane coupled with electro-assistance was developed for improving the antifouling and separation performance. The CNTs/ceramic flat sheet membrane was fabricated by coating cross-linked CNTs on ceramic membrane, featuring a good electroconductivity of 764.75 S/m. In the filtration of natural water, the permeate flux of the membrane with the cell voltage of -2.0 V was 1.8 times higher than that of the membrane without electro-assistance and 5.7-fold greater than that of the PVDF commercial membrane. Benefiting from the electro-assistance, the removal efficiency of the typical antibiotics was improved by 50%. Furthermore, the electro-assisted membrane filtration process showed 70% reduction in energy consumption compared with the filtration process of the commercial membrane. This work offers a feasible approach for membrane fouling mitigation and effluent quality improvement and suggests that the electro-assisted CNTs/ceramic membrane filtration process has great potential in the application of water treatment.  相似文献   

7.
• The membrane bioreactor cost decreased by 38.2% by decreasing HRT from 72 h to 36 h. • Capital and operation costs contributed 62.1% and 37.9% to decreased costs. • The membrane bioreactor is 32.6% cheaper than the oxidation ditch for treatment. • The effluent COD also improved from 709.93±62.75 mg/L to 280±17.32 mg/L. • Further treatment also benefited from lower pretreatment investment. A cost sensitivity analysis was performed for an industrial membrane bioreactor to quantify the effects of hydraulic retention times and related operational parameters on cost. Different hydraulic retention times (72–24 h) were subjected to a flat-sheet membrane bioreactor updated from an existing 72 h oxidation ditch treating antibiotic production wastewater. Field experimental data from the membrane bioreactor, both full-scale (500 m3/d) and pilot (1.0 m3/d), were used to calculate the net present value (NPV), incorporating both capital expenditure (CAPEX) and operating expenditure. The results showed that the tank cost was estimated above membrane cost in the membrane bioreactor. The decreased hydraulic retention time from 72 to 36 h reduced the NPV by 38.2%, where capital expenditure contributed 24.2% more than operational expenditure. Tank construction cost was decisive in determining the net present value contributed 62.1% to the capital expenditure. The membrane bioreactor has the advantage of a longer lifespan flat-sheet membrane, while flux decline was tolerable. The antibiotics decreased to 1.87±0.33 mg/L in the MBR effluent. The upgrade to the membrane bioreactor also benefited further treatments by 10.1%–44.7% lower direct investment.  相似文献   

8.
• DBP adsorption was tested using three kinds of substrates in constructed wetlands. • The DBP adsorption capacity followed the order: steel slag>gravel>shell sand. • High temperatures increased the DBP adsorption capacity in the substrates. • DOM consistently inhibited the DBP adsorption onto steel slag and gravel. In recent years, the presence and adverse impacts of phthalic acid esters in aquatic environments have gained increasing attention. This work investigated the adsorption behavior of a typical phthalic acid ester, dibutyl phthalate (DBP), onto steel slag, gravel, and shell sand (substrates commonly used in constructed wetlands). The influence of dissolved organic matter (DOM) on DBP adsorption was investigated using humic acid as a proxy for DOM. The results demonstrated that the adsorption of DBP to three substrates reached equilibrium within 96 h, and the adsorption kinetics were well fitted by a pseudo-second-order model. The DBP adsorption isotherms were best fitted by the Langmuir adsorption model. The DBP adsorption capacity decreased in the order of steel slag>gravel>shell sand, with values of 656 mg/kg, 598 mg/kg, and 6.62 mg/kg at 25°C, respectively. DBP adsorbed to the surface of all substrates in a monolayer via an endothermic process. The DBP adsorption capacities of steel slag and gravel decreased as the DOM content increased. The DBP adsorption mechanisms to steel slag and gravel mainly involved the surface coordination of DBP with –OH or –COOH groups and electrostatic interactions. The results of this work suggest that steel slag and gravel may be ideal substrates for use in constructed wetlands to treat wastewater polluted with DBP.  相似文献   

9.
• The source of DOM in surface water and sediment is inconsistent. • The DOC content changes differently in surface water and sediment. • The content of DOC in the surface water is lower than that in the sediment. • The DOM in the surface water had higher photodegradation potentials than sediment. Dissolved organic matter (DOM) in rivers is a critical regulator of the cycling and toxicity of pollutants and the behavior of DOM is a key indicator for the health of the environment. We investigated the sources and characteristics of DOM in surface water and sediment samples of the Wei River, China. Dissolved organic carbon (DOC) concentration and ultraviolet absorbance at 254 nm (UV254) increased in the surface water and were decreased in the sediment downstream, indicating that the source of DOM in the water differed from the sediment. Parallel factor (PARAFAC) analysis of the excitation-emission matrices (EEM) revealed the presence of terrestrial humus-like, microbial humus-like and tryptophan-like proteins in the surface water, whereas the sediment contained UVA humic-like, UVC humic-like and fulvic-like in the sediment. The DOM in the surface water and sediment were mainly derived from microbial metabolic activity and the surrounding soil. Surface water DOM displayed greater photodegradation potential than sediment DOM. PARAFAC analysis indicated that the terrestrial humic-like substance in the water and the fulvic-like component in the sediment decomposed more rapidly. These data describe the characteristics of DOM in the Wei River and are crucial to understanding the fluctuations in environmental patterns.  相似文献   

10.
• We created a combined system for treating oilfield polymer-flooding wastewater. • The system was composed of coagulation, hydrolysis acidification and DMBR. • Coagulant integrated with demulsifier dominated the removal of crude oil. • The DMBR proceed efficiently without serious membrane fouling. A combined system composed of coagulation, hydrolysis acidification and dynamic membrane bioreactor (DMBR) was developed for treating the wastewater produced from polymer flooding. Performance and mechanism of the combined system as well as its respective units were also evaluated. The combined system has shown high-capacity to remove all contaminants in the influent. In this work, the coagulant, polyacrylamide-dimethyldiallyammonium chloride-butylacrylate terpolymer (P(DMDAAC-AM-BA)), integrated with demulsifier (SD-46) could remove 91.8% of crude oil and 70.8% of COD. Hydrolysis acidification unit improved the biodegradability of the influent and the experimental results showed that the highest acidification efficiency in hydrolysis acidification reactor was 20.36% under hydraulic retention time of 7 h. The DMBR proceeded efficiently without serious blockage process of membrane fouling, and the concentration of ammonia nitrogen (NH3-N), oil, chemical oxygen demand and biological oxygen demand in effluent were determined to be 3.4±2.1, 0.3±0.6, 89.7±21.3 and 13±4.7 mg/L.  相似文献   

11.
• Graphite bipolar electrodes act as an appropriate bed for the CDI process. • Activated carbon Coating improves the application of the electrodes. • CDI is an environmentally friendly method to apply for brackish water. • Initial concentration is the most important parameter in the CDI method. • CDI process in a batch-mode setup needs more development. This research investigates a capacitive deionization method for salinity reduction in a batch reactor as a new approach for desalination. Reductions of cost and energy compared with conventional desalination methods are the significant advantages of this approach. In this research, experiments were performed with a pair of graphite bipolar electrodes that were coated with a one-gram activated carbon solution. After completing preliminary tests, the impacts of four parameters on electrical conductivity reduction, including (1) the initial concentration of feed solution, (2) the duration of the tests, (3) the applied voltage, and (4) the pH of the solution, were examined. The results show that the maximum efficiency of electrical conductivity reduction in this laboratory-scale reactor is about 55%. Furthermore, the effects of the initial concentration of feed solution are more significant than the other parameters. Thus, using the capacitive deionization method for water desalination with low and moderate salt concentrations (i.e., brackish water) is proposed as an affordable method. Compared with conventional desalination methods, capacitive deionization is not only more efficient but also potentially more environmentally friendly.  相似文献   

12.
• A high-performance electrode was prepared with super-aligned carbon nanotubes. • SACNT/AC electrode achieved a ~100% increase in desalination capacity and rate. • SACNT/AC electrode achieved a ~26% increase in charge efficiency. • CUF process with SACNT/AC achieved an up to 2.43-fold fouling reduction. • SACNT/AC imparts overall improved water purification efficiency. The practical application of the capacitive deionization (CDI) enhanced ultrafiltration (CUF) technology is hampered due to low performance of electrodes. The current study demonstrated a novel super-aligned carbon nanotube (SACNT)/activated carbon (AC) composite electrode, which was prepared through coating AC on a cross-stacked SACNT film. The desalination capability and water purification performance of the prepared electrode were systematically investigated at different applied voltages (0.8–1.2 V) with a CDI system and a CUF system, respectively. In the CDI tests, as compared with the control AC electrode, the SACNT/AC electrode achieved an approximately 100% increase in both maximum salt adsorption capacity and average salt adsorption rate under all the applied voltage conditions, demonstrating a superior desalination capability. Meanwhile, a conspicuous increase by an average of ~26% in charge efficiency was also achieved at all the voltages. In the CUF tests, as compared with the control run at 0 V, the treatment runs at 0.8, 1.0, and 1.2 V achieved a 2.40-fold, 2.08-fold, and 2.43-fold reduction in membrane fouling (calculated according to the final transmembrane pressure (TMP) data at the end of every purification stage), respectively. The average TMP increasing rates at 0.8, 1.0, and 1.2 V were also roughly two times smaller than that at 0 V, indicating a dramatical reduction of membrane fouling. The SACNT/AC electrode also maintained its superior desalination capability in the CUF process, resulting in an overall improved water purification efficiency.  相似文献   

13.
• Ceramic membrane filtration showed high performance for surface water treatment. • PTC pre-coagulation could enhance ceramic membrane filtration performance. • Ceramic membrane fouling was investigated by four varied mathematical models. • PTC pre-coagulation was high-effective for ceramic membrane fouling control. Application of ceramic membrane (CM) with outstanding characteristics, such as high flux and chemical-resistance, is inevitably restricted by membrane fouling. Coagulation was an economical and effective technology for membrane fouling control. This study investigated the filtration performance of ceramic membrane enhanced by the emerging titanium-based coagulant (polytitanium chloride, PTC). Particular attention was paid to the simulation of ceramic membrane fouling using four widely used mathematical models. Results show that filtration of the PTC-coagulated effluent using flat-sheet ceramic membrane achieved the removal of organic matter up to 78.0%. Permeate flux of ceramic membrane filtration reached 600 L/(m2·h), which was 10-fold higher than that observed with conventional polyaluminum chloride (PAC) case. For PTC, fouling of the ceramic membrane was attributed to the formation of cake layer, whereas for PAC, standard filtration/intermediate filtration (blocking of membrane pores) was also a key fouling mechanism. To sum up, cross-flow filtration with flat-sheet ceramic membranes could be significantly enhanced by titanium-based coagulation to produce both high-quality filtrate and high-permeation flux.  相似文献   

14.
• Mechanism of DCM disproportionation over mesoporous TiO2 was studied. • DCM was completely eliminated at 350℃ under 1 vol.% humidity. • Anatase (001) was the key for disproportionation. • A competitive oxidation route co-existed with disproportionation. • Disproportionation was favored at low temperature. Mesoporous TiO2 was synthesized via nonhydrolytic template-mediated sol-gel route. Catalytic degradation performance upon dichloromethane over as-prepared mesoporous TiO2, pure anatase and rutile were investigated respectively. Disproportionation took place over as-made mesoporous TiO2 and pure anatase under the presence of water. The mechanism of disproportionation was studied by in situ FTIR. The interaction between chloromethoxy species and bridge coordinated methylenes was the key step of disproportionation. Formate species and methoxy groups would be formed and further turned into carbon monoxide and methyl chloride. Anatase (001) played an important role for disproportionation in that water could be dissociated into surface hydroxyl groups on such structure. As a result, the consumed hydroxyl groups would be replenished. In addition, there was another competitive oxidation route governed by free hydroxyl radicals. In this route, chloromethoxy groups would be oxidized into formate species by hydroxyl radicals transfering from the surface of TiO2. The latter route would be more favorable at higher temperature.  相似文献   

15.
•Wood and its reassemblies are ideal substrates to develop novel photocatalysts. •Synthetic methods and mechanisms of wood-derived photocatalysts are summarized. •Advances in wood-derived photocatalysts for organic pollutant removal are summed up. •Metal doping, morphology control and semiconductor coupling methods are highlighted. •Structure-activity relationship and catalytic mechanism of photocatalysts are given. Wood-based nanotechnologies have received much attention in the area of photocatalytic degradation of organic contaminants in aquatic environment in recent years, because of the high abundance and renewability of wood as well as the high reaction activity and unique structural features of these materials. Herein, we present a comprehensive review of the current research activities centering on the development of wood-based nanocatalysts for photodegradation of organic pollutants. This review begins with a brief introduction of the development of photocatalysts and hierarchical structure of wood. The review then focuses on strategies of designing novel photocatalysts based on wood or its recombinants (such as 1D fiber, 2D films and 3D porous gels) using advanced nanotechnology including sol-gel method, hydrothermal method, magnetron sputtering method, dipping method and so on. Next, we highlight typical approaches that improve the photocatalytic property, including metal element doping, morphology control and semiconductor coupling. Also, the structure-activity relationship of photocatalysts is emphasized. Finally, a brief summary and prospect of wood-derived photocatalysts is provided.  相似文献   

16.
• Effects of metabolic uncouplers addition on sludge reduction were carried out. • TCS addition effectively inhibited ATP synthesis and reduced sludge yield. • The effluent quality such as TOC and ammonia deteriorated but not significantly. • Suitable dosage retarded biofouling during sludge water recovery by UF membrane. Energy uncoupling is often used for sludge reduction because it is easy to operate and does not require a significant amount of extra equipments (i.e. no additional tank required). However, over time the supernatant extracted using this method can deteriorate, ultimately requiring further treatment. The purpose of this study was to determine the effect of using a low-pressure ultrafiltration membrane process for sludge water recovery after the sludge had undergone an energy uncoupling treatment (using 3,3′,4′,5-tetrachlorosalicylanilide (TCS)). Energy uncoupling was found to break apart sludge floc by reducing extracellular polymeric substances (EPS) and adenosine triphosphate (ATP) content. Analysis of supernatant indicated that when energy uncoupling and membrane filtration were co-applied and the TCS dosage was below 30 mg/L, there was no significant deterioration in organic component removal. However, ammonia and phosphate concentrations were found to increase as the concentration of TCS added increased. Additionally, due to low sludge concentrations and EPS contents, addition of 30–60 mg/L TCS during sludge reduction increased the permeate flux (two times higher than the control) and decreased the hydraulic reversible and cake layer resistances. In contrast, high dosage of TCS aggravated membrane fouling by forming compact fouling layers. In general, this study found that the co-application of energy uncoupling and membrane filtration processes represents an effective alternative method for simultaneous sludge reduction and sludge supernatant recovery.  相似文献   

17.
• Underwater superoleophobic membrane was fabricated by deposition of catechol/chitosan. • The membrane had ultrahigh pure water flux and was stable under harsh pH conditions. • The membrane exhibited remarkable antifouling property in O/W emulsion separation. • The hydration layer on the membrane surface prevented oil droplets adhesion. Low-pressure membrane filtrations are considered as effective technologies for sustainable oil/water separation. However, conventional membranes usually suffer from severe pore clogging and surface fouling, and thus, novel membranes with superior wettability and antifouling features are urgently required. Herein, we report a facile green approach for the development of an underwater superoleophobic microfiltration membrane via one-step oxidant-induced ultrafast co-deposition of naturally available catechol/chitosan on a porous polyvinylidene fluoride (PVDF) substrate. Membrane morphology and surface chemistry were studied using a series of characterization techniques. The as-prepared membrane retained the original pore structure due to the ultrathin and uniform catechol/chitosan coating. It exhibited ultrahigh pure water permeability and robust chemical stability under harsh pH conditions. Moreover, the catechol/chitosan hydrophilic coating on the membrane surface acting as an energetic barrier for oil droplets could minimize oil adhesion on the surface, which endowed the membrane with remarkable antifouling property and reusability in a cyclic oil-in-water (O/W) emulsion separation. The modified membrane exhibited a competitive flux of ~428 L/(m2·h·bar) after three filtration cycles, which was 70% higher than that of the pristine PVDF membrane. These results suggest that the novel underwater superoleophobic membrane can potentially be used for sustainable O/W emulsions separation, and the proposed green facile modification approach can also be applied to other water-remediation materials considering its low cost and simplicity.  相似文献   

18.
• High hydrogen yield is recovered from thermal-alkaline pretreated sludge. • Separating SFL by centrifugation is better than filtration for hydrogen recovery. • The cascaded bioconversion of complex substrates in MECs are studied. • Energy and electron efficiency related to substrate conversion are evaluated. The aim of this study was to investigate the biohydrogen production from thermal (T), alkaline (A) or thermal-alkaline (TA) pretreated sludge fermentation liquid (SFL) in a microbial electrolysis cells (MECs) without buffer addition. Highest hydrogen yield of 36.87±4.36 mgH2/gVSS (0.026 m3/kg COD) was achieved in TA pretreated SFL separated by centrifugation, which was 5.12, 2.35 and 43.25 times higher than that of individual alkaline, thermal pretreatment and raw sludge, respectively. Separating SFL from sludge by centrifugation eliminated the negative effects of particulate matters, was more conducive for hydrogen production than filtration. The accumulated short chain fatty acid (SCFAs) after pretreatments were the main substrates for MEC hydrogen production. The maximum utilization ratio of acetic acid, propionic acid and n-butyric acid was 93.69%, 90.72% and 91.85%, respectively. These results revealed that pretreated WAS was highly efficient to stimulate the accumulation of SCFAs. And the characteristics and cascade bioconversion of complex substrates were the main factor that determined the energy efficiency and hydrogen conversion rate of MECs.  相似文献   

19.
• Shale oil and gas production generates wastewater with complex composition. • Membrane technologies emerged for the treatment of shale oil and gas wastewater. • Membrane technologies should tolerate high TDS and consume low primary energy. • Pretreatment is a key component of integrated wastewater treatment systems. • Full-scale implementation of membrane technologies is highly desirable. Shale oil and gas exploitation not only consumes substantial amounts of freshwater but also generates large quantities of hazardous wastewater. Tremendous research efforts have been invested in developing membrane-based technologies for the treatment of shale oil and gas wastewater. Despite their success at the laboratory scale, membrane processes have not been implemented at full scale in the oil and gas fields. In this article, we analyze the growing demands of wastewater treatment in shale oil and gas production, and then critically review the current stage of membrane technologies applied to the treatment of shale oil and gas wastewater. We focus on the unique niche of those technologies due to their advantages and limitations, and use mechanical vapor compression as the benchmark for comparison. We also highlight the importance of pretreatment as a key component of integrated treatment trains, in order to improve the performance of downstream membrane processes and water product quality. We emphasize the lack of sufficient efforts to scale up existing membrane technologies, and suggest that a stronger collaboration between academia and industry is of paramount importance to translate membrane technologies developed in the laboratory to the practical applications by the shale oil and gas industry.  相似文献   

20.
• Fate of microplastics in integrated membrane system for water reuse was investigated. • Integrated membrane system has high removal efficiency (>98%) for microplastics. • Microplastics (>93%) were mainly removed through membrane bioreactor treatment. • Small scale fiber plastics (<200 μm) could break through reverse osmosis (RO) system. • The flux of microplastics maintained at 2.7 × 1011 MPs/d after the RO treatment. Rare information on the fate of microplastics in the integrated membrane system (IMS) system in full-scale wastewater treatment plant was available. The fate of microplastics in IMS in a coastal reclaimed water plant was investigated. The removal rate of microplastics in the IMS system reached 93.2% after membrane bioreactor (MBR) treatment while that further increased to 98.0% after the reverse osmosis (RO) membrane process. The flux of microplastics in MBR effluent was reduced from 1.5 × 1013 MPs/d to 10.2 × 1011 MPs/d while that of the RO treatment decreased to 2.7 × 1011 MPs/d. Small scale fiber plastics (<200 μm) could break through RO system according to the size distribution analysis. The application of the IMS system in the reclaimed water plant could prevent most of the microplastics from being discharged in the coastal water. These findings suggested that the IMS system was more efficient than conventional activated sludge system (CAS) for the removal of microplastics, while the discharge of small scale fiber plastics through the IMS system should also not be neglected because small scale fiber plastics (<200 μm) could break through IMS system equipped with the RO system.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号