共查询到18条相似文献,搜索用时 437 毫秒
1.
2.
针对铅芯橡胶隔震支座在大变形多次实时往复荷载下力学性能退化问题,采用足尺铅芯橡胶隔震支座,通过高速压剪试验设备,对铅芯橡胶隔震支座进行了基本竖向力学性能试验、基本水平力学性能试验、多次不同大变形下实时加载水平力学性能试验,试验结果显示:铅芯橡胶隔震支座在实时往复多次大变形下,随着加载圈数的增加,隔震支座屈服力急剧下降,支座耗能能力降低,到试验结束时屈服力平均下降46.1%,加载圈数对屈服后刚度影响相对较小;实时往复大变形下测得的铅芯橡胶隔震支座屈服力在第2圈以后均小于采用国家标准试验方法得到的屈服力,试验结束时屈服力小于国家标准测到屈服力的43.8%,国家标准试验方法测得的屈服力与实际地震下铅芯橡胶隔震支座的屈服力相比偏小;铅芯橡胶隔震支座实时多次往复变形对其竖向刚度基本没有影响;铅芯橡胶隔震支座在实时往复大变形试验时其力学性能退化,静置一段时间后,其性能基本又恢复到实时往复大变形试验前的状态。 相似文献
3.
铅芯橡胶支座是一种常用的阻尼机构一体型隔震装置,其水平方向的滞回性能反映了该装置的耗能能力并影响整个隔震建筑的隔震效果,是隔震装置的一个关键指标.基于某铅芯橡胶支座基础隔震结构的模型振动台试验数据,对该隔震装置在不同地震加速度记录、不同地震强度、不同地震输入方向等各种工况下的滞回曲线进行了对比与分析,得到了一些有益的结论. 相似文献
4.
针对铅芯橡胶隔震支座在长周期长持时地震作用下由于铅芯温度上升发生力学性能退化的问题,通过压剪设备对铅芯橡胶隔震支座进行了快速水平往复力学性能试验,研究其在快速往复加载下水平剪切力学性能的变化。试验结果表明,铅芯橡胶隔震支座在快速往复荷载作用下,随着加载次数的增多,其特征强度显著下降,且前期下降的幅度比后期大,屈服后刚度在加载过程中变化较为平缓。然后基于试验结果,采用改良的广义Bouc-Wen模型,提出了铅芯橡胶隔震支座在快速水平荷载下力学性能退化的力学模型,然后基于铅芯橡胶隔震支座性能退化的力学模型,对一实际隔震结构进行仿真,研究该结构在长周期长持时地震作用下的动力响应。仿真结果表明考虑支座退化效应得到的隔震层位移和层间位移角不仅比不考虑支座退化效应得到的大,且最大值已超出设计允许范围,因此在基础隔震设计时建议要考虑铅芯橡胶隔震支座在长周期长持时地震作用下力学性能退化情况。 相似文献
5.
6.
铅芯橡胶支座参数对隔震储罐地震响应的影响 总被引:3,自引:0,他引:3
利用Bouc-Wen模型模拟铅芯橡胶支座的力-变形非线性行为,研究了两种高径比铅芯橡胶支座(LRB)隔震储罐的地震动力响应特征,系统探讨铅芯橡胶支座动力参数对隔震储罐地震反应的影响规律.研究表明:基底设置铅芯橡胶支座后,储罐有良好的减震效果,减震效果评价指标基底剪力、支座位移、晃动波高都得到有效控制.隔震频率是影响LRB隔震储罐减震性能的主要参数,屈服强度参数、支座阻尼比影响次之.增大支座屈服强度可增加有效隔震频率范围,降低支座位移,但不一定能起到降低波高作用.高隔震频率、无阻尼比工况时,储罐地震响应远超过未隔震时响应;增大阻尼比可同时降低支座位移和晃动波高.在高隔震频率下,存在最优屈服强度和阻尼比,使得基底剪力最小.为使隔震支座发挥最大减震作用,应根据储罐不同高径比特点来优化配置铅芯橡胶支座参数. 相似文献
7.
通过对不同结构构造的铅芯橡胶支座进行水平动态力学试验,系统研究了铅芯橡胶支座动态力学性能与其结构构造及外加动载之间的关系。在支座直径、橡胶和薄钢板厚度不变的情况下,分析了不同倾角或曲率的铅芯橡胶隔震支座在竖向荷载和剪切荷载作用下的力学性能;研究了竖向刚度、水平等效刚度、屈服后刚度、屈服力、等效阻尼比等的变化规律。研究结果表明,竖向刚度随倾角或曲率的增加呈减小趋势,水平等效刚度、屈服后刚度、屈服力、等效阻尼比随倾角或曲率的增加呈增大趋势;同时通过数值分析精确的验证了新型铅芯橡胶支座具有良好的减隔震效果。 相似文献
8.
隔震支座是隔震结构地震响应控制的关键构件,滑移铅芯橡胶隔震支座具有协调上部结构温致变形、地震作用下可耗能复位等优势,但往复荷载作用下其力学性能退化显著。文章建立考虑支座性能退化的滑移铅芯橡胶支座精细数值模型,开展不同竖向压力、加载频率、加载位移幅值时滑移铅芯橡胶支座压剪力学性能分析,并基于支座试验结果验证模型的准确性,进一步探明支座性能退化对隔震桥梁地震响应的影响。结果表明:竖向压力增大会改变滑移铅芯橡胶支座的滞回力-位移关系,从而提升其耗能性能;加载频率对摩擦力的影响随加载频率增大而显著减小;加载位移幅值越大,支座单周耗能能力、等效刚度随滞回周期的增加减小越显著;相比已有数值模型,考虑支座性能退化的精细数值模型分析结果与试验结果吻合更好,模型误差显著减小。隔震周期越大,支座性能退化对隔震桥梁地震响应的影响越显著,应在隔震结构设计与性能分析中予以关注。 相似文献
9.
10.
11.
12.
13.
14.
Yang Linde Ji Qianqian Zheng Yonglai Yang Chao Zhang Dongliang 《Frontiers of Architecture and Civil Engineering in China》2007,1(2):194-197
A reasonable choice of structure of a model box is significant for a shaking table test to be successful in geotechnical engineering.
A model box has been designed for the shaking table test of a subway station structure in the soft soil of Shanghai in the
paper. The reasonable geometric similarity scale of the subway station structure has been determined by a 3-D dynamic analysis
under the action of lateral equivalent static loading. The shape, size and structure of the model box are chosen by considering
all the involved factors comprehensively. The shape of the box is similar to that of a typical station structure, and the
ratio between the plane dimension of the model ground and that of the model structure is big enough to reduce the influence
of boundary condition effectively. The structure is strong enough to avoid being demolished by shaking during a test. The
contact conditions between the model soil and box are clear to help the data gained from the test well fit that from numerical
analysis. The total weight of the model soil and box is less than the bearing capacity of the shaking table apparatus and
there is no resonance between the model soil and box. The results show that the model box can be used to simulate the dynamic
response of a subway station structure very well, so it provides a firm foundation for the success of the shaking table test
of a subway station structure.
Translated from Chinese Journal of Geotechnical Engineering, 2004, 26(1): 75–78 [译自: 岩土工程学报] 相似文献
15.
对适用于大跨结构的大吨位摩擦摆隔震支座进行了振动台试验研究,该支座通过支座的滑动面与滑块之间的摩擦来达到消耗地震能量,通过测试该支座在不同水准地震作用下的地震反应,可以得出,该支座随着地震作用的增大,滞回曲线变得清晰完整,包络面积在增大,耗能能力在增强,最大减振效果达到了64.21%,且模型的结构频率没有因地震作用而发生明显改变,力学及承载性能保持较好。 相似文献
16.
通过模拟地震振动台试验,研究了基础隔震结构的竖向地震反应特点.首先通过对不同支座的竖向力进行比较可知,基础隔震结构在遭遇水平地震波时,位于支座布置平面中非对称轴的支座处可能产生较大的竖向反应;其次对隔震结构和非隔震结构的竖向地震反应进行对比分析可知,基础隔震结构对于竖向地震动的隔震效果不明显.因此竖向地震动对结构的作用不可忽视,在进行基础隔震结构抗震设计中应加以关注. 相似文献
17.
对一缩尺1:4的采用非固结锥形隔震支座的钢框架结构模型进行了水平和竖向单向地震波输入下的振动台试验。通过输入不同类型的地震波,分析上部结构和锥形支座的地震反应。试验结果表明,在8度和9度罕遇地震作用下,上部结构的加速度峰值比输入加速度峰值增加10%~50%,和普通抗震结构相比具有明显的减震效果。由支座的滞回曲线可以看出,上下盖板会在地震作用下产生错动位移,同时挤压粘弹性体消耗地震能量。试验结果表明,非固结锥形隔震支座具有良好的减震性能,对低层建筑结构的减震具有明显的推广价值。 相似文献
18.
长度超过百米的地下结构受到地震动空间变异性的影响较大,为深入了解粉质粘土地基条件下地铁车站在非一致地震动激励下的动力反应规律,设计并完成了粉质粘土地基条件下非一致地震动激励下地铁车站模型的振动台试验。采用ABAQUS软件建立了三维有限元模型,模拟考虑非一致波动输入的地铁车站振动台试验模型。对比了有限元试验模型与振动台试验的基频和加速度结果,以及有限元试验模型与实际地铁车站有限元模型的内力和加速度结果。通过三者的相互验证,对非一致波动输入地铁车站振动台试验的方法进行了研究。 相似文献