首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
It has not yet been possible to quantify dose‐related health risks attributable to indoor dampness or mold (D/M), to support setting specific health‐related limits for D/M. An overlooked target for assessing D/M is moisture in building materials, the critical factor allowing microbial growth. A search for studies of quantified building moisture and occupant health effects identified 3 eligible studies. Two studies assessed associations between measured wall moisture content and respiratory health in the UK. Both reported dose‐related increases in asthma exacerbation with higher measured moisture, with 1 study reporting an adjusted odds ratio of 7.0 for night‐time asthma symptoms with higher bedroom moisture. The third study assessed relationships between infrared camera‐determined wall moisture and atopic dermatitis in South Korea, reporting an adjusted odds ratio of 14.5 for water‐damaged homes and moderate or severe atopic dermatitis. Measuring building moisture has, despite extremely limited available findings, potential promise for detecting unhealthy D/M in homes and merits more research attention. Further research to validate these findings should include measured “water activity,” which directly assesses moisture availability for microbial growth. Ultimately, evidence‐based, health‐related thresholds for building moisture, across specific materials and measurement devices, could better guide assessment and remediation of D/M in buildings.  相似文献   

2.
Microbial indoor air quality and respiratory symptoms of children were studied in 24 schools with visible moisture and mold problems, and in eight non-damaged schools. School buildings of concrete/brick and wooden construction were included. The indoor environment investigations included technical building inspections for visible moisture signs and microbial sampling using six-stage impactor for viable airborne microbes. Children's health information was collected by questionnaires. The effect of moisture damage on concentrations of fungi was clearly seen in buildings of concrete/brick construction, but not in wooden school buildings. Occurrence of Cladosporium, Aspergillus versicolor, Stachybotrys, and actinobacteria showed some indicator value for moisture damage. Presence of moisture damage in school buildings was a significant risk factor for respiratory symptoms in schoolchildren. Association between moisture damage and respiratory symptoms of children was significant for buildings of concrete/brick construction but not for wooden school buildings. The highest symptom prevalence was found during spring seasons, after a long exposure period in damaged schools. The results emphasize the importance of the building frame as a determinant of exposure and symptoms.  相似文献   

3.
Moisture-damaged buildings are associated with respiratory symptoms and underlying diseases among building occupants, but the causative agent(s) remain a mystery. We first identified specific fungal and bacterial taxa in classrooms with moisture damage in Finnish and Dutch primary schools. We then investigated associations of the identified moisture damage indicators with respiratory symptoms in more than 2700 students. Finally, we explored whether exposure to specific taxa within the indoor microbiota may explain the association between moisture damage and respiratory health. Schools were assessed for moisture damage through detailed inspections, and the microbial composition of settled dust in electrostatic dustfall collectors was determined using marker-gene analysis. In Finland, there were several positive associations between particular microbial indicators (diversity, richness, individual taxa) and a respiratory symptom score, while in the Netherlands, the associations tended to be mostly inverse and statistically non-significant. In Finland, abundance of the Sphingomonas bacterial genus and endotoxin levels partially explained the associations between moisture damage and symptom score. A few microbial taxa explained part of the associations with health, but overall, the observed associations between damage-associated individual taxa and respiratory health were limited.  相似文献   

4.
Microbial exposures in homes of asthmatic adults have been rarely investigated; specificities and implications for respiratory health are not well understood. The objectives of this study were to investigate associations of microbial levels with asthma status, asthma symptoms, bronchial hyperresponsiveness (BHR), and atopy. Mattress dust samples of 199 asthmatics and 198 control subjects from 7 European countries participating in the European Community Respiratory Health Survey II study were analyzed for fungal and bacterial cell wall components and individual taxa. We observed trends for protective associations of higher levels of mostly bacterial markers. Increased levels of muramic acid, a cell wall component predominant in Gram‐positive bacteria, tended to be inversely associated with asthma (OR's for different quartiles: II 0.71 [0.39‐1.30], III 0.44 [0.23‐0.82], and IV 0.60 [0.31‐1.18] P for trend .07) and with asthma score (P for trend .06) and with atopy (P for trend .02). These associations were more pronounced in northern Europe. This study among adults across Europe supports a potential protective effect of Gram‐positive bacteria in mattress dust and points out that this may be more pronounced in areas where microbial exposure levels are generally lower.  相似文献   

5.
This study investigated the association between confirmed moisture damage in homes and systemic subclinical inflammation in children. Home inspections were performed in homes of 291 children at the age of 6 years. Subclinical inflammation at the age of 6 years was assessed by measuring the circulating levels of C‐reactive protein (CRP) and leukocytes in peripheral blood and fractional exhaled nitric oxide (FeNO). Proinflammatory cytokines interleukin (IL)‐1β and IL‐6 and tumor necrosis factor (TNF)‐α were measured in unstimulated, and in phorbol 12‐myristate 13‐acetate and ionomycin (PI), lipopolysaccharide (LPS), or peptidoglycan (PPG)‐stimulated whole blood. Major moisture damage in the child's main living areas (living room, kitchen, or child's bedroom) and moisture damage with mold in the bathroom were associated with increased levels of CRP and stimulated production of several proinflammatory cytokines. There were no significant associations between moisture damage/visible mold and leukocyte or FeNO values. The results suggest that moisture damage or mold in home may be associated with increased systemic subclinical inflammation and proinflammatory cytokine responsiveness.  相似文献   

6.
In the Swedish Building Energy, Technical Status and Indoor environment study, a total of 1160 adults from 605 single‐family houses answered a questionnaire on respiratory health. Building inspectors investigated the homes and measured temperature, air humidity, air exchange rate, and wood moisture content (in attic and crawl space). Moisture load was calculated as the difference between indoor and outdoor absolute humidity. Totally, 7.3% were smokers, 8.7% had doctor’ diagnosed asthma, 11.2% current wheeze, and 9.5% current asthma symptoms. Totally, 50.3% had respiratory infections and 26.0% rhinitis. The mean air exchange rate was 0.36/h, and the mean moisture load 1.70 g/m3. Damp foundation (OR=1.79, 95% CI 1.16‐2.78) was positively associated while floor constructions with crawl space (OR=0.49, 95% CI 0.29‐0.84) was negatively associated with wheeze. Concrete slabs with overlying insulation (OR=2.21, 95% CI 1.24‐3.92) and brick façade (OR=1.71, 95% CI 1.07‐2.73) were associated with rhinitis. Moisture load was associated with respiratory infections (OR=1.21 per 1 g/m3, 95% CI 1.04‐1.40) and rhinitis (OR=1.36 per 1 g/m3, 95% CI 1.02‐1.83). Air exchange rate was associated with current asthma symptoms (OR=0.85 per 0.1/h, 95% CI 0.73‐0.99). Living in homes with damp foundation, concrete slabs with overlying insulation, brick façade, low ventilation flow, and high moisture load are risk factors for asthma, rhinitis, and respiratory infections.  相似文献   

7.
A total of 630 randomly selected dwellings were surveyed for visible signs of moisture damage by civil engineers, and questionnaire responses were collected from the occupants (a total of 1,017 adults) to analyse the association between moisture damage and occupant health. A three-level grading system was developed, which took into account the number of damage sites in buildings and estimated the severity of the damage. In the present study, this grading system was tested as an improved model of moisture damage-related exposure in comparison to a conventional two-category system: based on independent, technical criteria it also allowed dose-response to be estimated. The questionnaire probed 28 individual health symptoms, based on earlier reported associations with building moisture and mould-related exposure. Criteria in evaluating the goodness of the selected exposure model were (1) dose-responsiveness and (2) higher risk compared to a two-level classification. Dose-responsiveness was observed with the three-level classification in 7, higher risk in 10, and both criteria in 5 out of 28 health symptoms. Two-level classification had higher risk in 4 health symptoms. Dose-dependent risk increases for respiratory infections and lower respiratory symptoms, and recurrent irritative and skin symptoms were observed with the three-level classification using symptom score variables. Although the results did not unambiguously support the three-level model, they underline the importance of developing more accurate exposure models in assessing the severity of moisture damage.  相似文献   

8.
9.
This paper provides meta‐analyses of the published findings relating the respiratory health of occupants of schools with visible dampness, water damage, visible mold, and/or mold odor. Random effects models were used to develop central estimates and confidence limits for the associations of respiratory health effects with school dampness and mold. Eleven studies, all with cross‐sectional designs, were included in the meta‐analyses; however, analyses for some health outcomes were based on as few as four studies. Analyses were performed using data from adults and children combined, using only data from children, and using data from adults and children after excluding two studies. The central estimates of odds ratios from the meta‐analyses were consistently above unity. The evidence of adverse health effects was strongest for cough and wheeze, which had confidence limits excluding unity in some or all analyses. The odds ratios of 1.32 for cough and 1.68 for wheeze suggest moderate increases in health risk. Studies not included in the meta‐analyses provide additional evidence that dampness and mold in schools are associated with adverse health outcomes. These meta‐analyses and the published literature not included in the meta‐analyses suggest that dampness and mold in schools are associated with adverse respiratory health effects.  相似文献   

10.
The National Institute for Occupational Safety and Health (NIOSH) received a request for evaluation of a water-damaged office building which housed approximately 1300 employees. Workers reported respiratory conditions that they perceived to be building related. We hypothesized that these symptoms were associated with airways inflammation. To test this hypothesis, we assessed airways inflammation in employees using exhaled breath condensate (EBC) and the fraction of exhaled nitric oxide (FENO). In September 2001, a health questionnaire was offered to all employees. Based on this questionnaire, NIOSH invited 356 symptomatic and asymptomatic employees to participate in a medical survey. In June 2002, these employees were offered questionnaire, spirometry, methacholine challenge test, allergen skin prick testing, EBC and FENO. FENO or EBC were completed by 239 participants. As smoking is highly related to the measurements that we used in this study, we included only the 207 current non-smokers in the analyses. EBC interleukin-8 (IL-8) levels, but not nitrite, were significantly higher among workers with respiratory symptoms and in the physician-diagnosed asthmatic group. Of the analyses assessed, EBC IL-8 showed the most significant relationship with a number of symptoms and physician-diagnosed asthma. PRACTICAL IMPLICATIONS: Implementation of exhaled breath condensate and exhaled nitric oxide in indoor air quality problems.  相似文献   

11.
We investigated the effect of weekends and school holidays on the daily frequency and severity of respiratory and other symptoms among children attending schools with (index) or without (reference) moisture damage in Spain, the Netherlands, and Finland. Throughout 1 year, parents of 419 children with a respiratory condition attending index (n=15) or reference (n=10) primary schools completed three symptom diaries. We assessed associations between lower respiratory tract, upper respiratory tract or allergy, and other symptom scores and school day, weekend, or summer holiday using mixed regression models stratified by country and moisture damage. We evaluated interactions between moisture damage and type of day. We combined country‐specific estimates (incidence rate ratios [IRRs] and 95% confidence interval [CI]) in meta‐analyses. Symptom scores were lower during weekends and holiday. Lower respiratory tract symptoms were statistically significantly less common during holiday with strongest effect in index schools (IRR=0.7; CI=0.6–0.8). Reporting of other symptoms was more reduced during holiday in index (IRR=0.6; CI=0.4–0.9) than in reference (IRR=0.95; CI=0.8–1.2) schools (interaction P<.01). In conclusion, symptoms were less frequent and/or severe during summer holiday and weekends. This pattern was stronger among children attending moisture‐damaged schools, suggesting potential improvement in moisture damage‐related symptoms during school breaks.  相似文献   

12.
Little is known about the health effects of school‐related indoor dampness and microbial exposures. In this study, we investigated dampness and dampness‐related agents in both homes and schools and their association with allergy and respiratory health effects in 330 Danish pupils. Classroom dampness was identified based on technical inspection and bedroom dampness on parents' self‐report. Classroom and bedroom dust was analyzed for seven microbial components. Skin prick testing determined atopic sensitization. Lung function was expressed as z‐scores for forced expiratory volume in one‐second (zFEV1), forced vital capacity (zFVC) and the ratio zFEV1/zFVC using GLI‐2012 prediction equations. The parents reported children's allergies, airway symptoms, and doctor‐diagnosed asthma. High classroom dampness, but not bedroom dampness, was negatively associated with zFEV1 (β‐coef. ?0.71; 95% CI ?1.17 to ?0.23) and zFVC (β‐coef. ?0.52; 95% CI ?0.98 to ?0.06) and positively with wheezing (OR 8.09; 95% CI 1.49 to 43.97). No consistent findings were found between any individual microbial components or combination of microbial components and health outcomes. Among other indoor risk factors, environmental tobacco smoke (ETS) decreased zFEV1 (β‐coef. ?0.22; 95% CI ?0.42 to ?0.02) and zFEV1/zFVCratio (β‐coef. ?0.26; 95% CI ?0.44 to ?0.07) and increased upper airway symptoms (OR 1.66; 95% CI 1.03–2.66). In conclusion, dampness in classrooms may have adverse respiratory health effects in pupils, but microbial agents responsible for this effect remain unknown.  相似文献   

13.
Aiming to identify factors causing the adverse health effects associated with moisture‐damaged indoor environments, we analyzed immunotoxicological potential of settled dust from moisture‐damaged and reference schools in relation to their microbiological composition. Mouse RAW264.7 macrophages were exposed to settled dust samples (n = 25) collected from moisture‐damaged and reference schools in Spain, the Netherlands, and Finland. After exposure, we analyzed production of inflammatory markers [nitric oxide (NO), tumor necrosis factor‐α (TNF‐)α, interleukin (IL)‐6, and macrophage inflammatory protein (MIP)2] as well as mitochondrial activity, viability, apoptosis, and cell cycle arrest. Furthermore, particle counts, concentration of selected microbial groups as well as chemical markers such as ergosterol, 3‐hydroxy fatty acids, muramic acid, endotoxins, and glucans were measured as markers of exposure. Dust from moisture‐damaged schools in Spain and the Netherlands induced stronger immunotoxicological responses compared to samples from reference schools; the responses to Finnish samples were generally lower with no difference between the schools. In multivariate analysis, IL‐6 and apoptosis responses were most strongly associated with moisture status of the school. The measured responses correlated with several microbial markers and numbers of particles, but the most important predictor of the immunotoxicological potential of settled dust was muramic acid concentration, a marker of Gram‐positive bacteria.  相似文献   

14.
Exposure to moisture‐damaged indoor environments is associated with adverse respiratory health effects, but responsible factors remain unidentified. In order to explore possible mechanisms behind these effects, the oxidative capacity and hemolytic activity of settled dust samples (n = 25) collected from moisture‐damaged and non‐damaged schools in Spain, the Netherlands, and Finland were evaluated and matched against the microbial content of the sample. Oxidative capacity was determined with plasmid scission assay and hemolytic activity by assessing the damage to isolated human red blood cells. The microbial content of the samples was measured with quantitative PCR assays for selected microbial groups and by analyzing the cell wall markers ergosterol, muramic acid, endotoxins, and glucans. The moisture observations in the schools were associated with some of the microbial components in the dust, and microbial determinants grouped together increased the oxidative capacity. Oxidative capacity was also affected by particle concentration and country of origin. Two out of 14 studied dust samples from moisture‐damaged schools demonstrated some hemolytic activity. The results indicate that the microbial component connected with moisture damage is associated with increased oxidative stress and that hemolysis should be studied further as one possible mechanism contributing to the adverse health effects of moisture‐damaged buildings.  相似文献   

15.
Most previous research on indoor environments and health has studied school children or occupants in non‐school settings. This investigation assessed building‐related health symptoms and classroom characteristics via telephone survey of New York State school teachers. Participants were asked about 14 building‐related symptoms and 23 classroom characteristics potentially related to poor indoor air quality (IAQ). Poisson regression analysis was used to assess the relationship between these symptoms and each classroom characteristic, controlling for potential confounders. About 500 teachers completed the survey. The most frequently reported classroom characteristics included open shelving (70.7%), food eaten in class (65.5%), dust (59.1%), and carpeting (46.9%). The most commonly reported symptoms included sinus problems (16.8%), headache (15.0%), allergies/congestion (14.8%), and throat irritation (14.6%). Experiencing one or more symptoms was associated most strongly with reported dust (relative risk (RR) = 3.67; 95% confidence interval (CI): 2.62–5.13), dust reservoirs (RR = 2.13; 95% CI: 1.72–2.65), paint odors (RR = 1.73; 95% CI: 1.40–2.13), mold (RR = 1.71; 95% CI: 1.39–2.11), and moldy odors (RR = 1.65 95% CI: 1.30–2.10). Stronger associations were found with increasing numbers of reported IAQ‐related classroom characteristics. Similar results were found with having any building‐related allergic/respiratory symptom. This research adds to the body of evidence underscoring the importance to occupant health of school IAQ.  相似文献   

16.
Park JH  Cox-Ganser J  Rao C  Kreiss K 《Indoor air》2006,16(3):192-203
We investigated the associations of fungal and endotoxin levels in office dust with respiratory health in 888 (67% participation) occupants of a water-damaged building. We analyzed floor and chair dusts from 338 workstations for culturable fungi and endotoxin. Based on averages, we ranked each floor of the building as low, medium, or high for occupants' exposure to each of these agents. Multivariate logistic regression models for building-related symptoms included this ranking of fungi and endotoxin, age, gender, race, smoking status, and duration of occupancy. Using floor dust measures, we found significantly increased odds for lower respiratory symptoms [wheeze, chest tightness, attacks of shortness of breath, and attacks of cough: odds ratios (OR) = 1.7 (95% confidence interval (CI): 1.02-2.77) to 2.4 (95% CI: 1.29-4.59)], throat irritation [OR = 1.7, (95% CI: 1.06-2.82)], and rash/itchy skin [OR = 3.0, (95% CI: 1.47-6.19)] in the highest fungal exposure group compared to the lowest, with generally linear exposure-response relationships. Nonlinear relationships were observed for many of these symptoms and endotoxin in floor dust. Interaction models showed that endotoxin modified effects of fungi on respiratory symptoms. Our findings of exposure interactions and exposure-response relationships of fungal and endotoxin with increased risk of building-related symptoms contribute to an understanding of the role of microbial agents in building-related asthma and respiratory and systemic symptoms. PRACTICAL IMPLICATIONS: Our demonstration of exposure-response relationships between measurements of fungi and/or endotoxin in floor dusts and building-related symptoms implies that microbial agents in floor dust may be a good surrogate measure for dampness-related bioaerosol exposure, considering that measurements of microbial agents in air often fail to demonstrate the associations between exposure and health. In addition, our finding that endotoxin exposure may change the effect of fungal exposure (and vice versa) on respiratory heath suggests that exposure to both fungi and endotoxin should be assessed in epidemiological investigations examining the effect of fungal or endotoxin exposure on respiratory health in indoor environments.  相似文献   

17.
Mendell MJ  Heath GA 《Indoor air》2005,15(1):27-52
To assess whether school environments can adversely affect academic performance, we review scientific evidence relating indoor pollutants and thermal conditions, in schools or other indoor environments, to human performance or attendance. We critically review evidence for direct associations between these aspects of indoor environmental quality (IEQ) and performance or attendance. Secondarily, we summarize, without critique, evidence on indirect connections potentially linking IEQ to performance or attendance. Regarding direct associations, little strongly designed research was available. Persuasive evidence links higher indoor concentrations of NO(2) to reduced school attendance, and suggestive evidence links low ventilation rates to reduced performance. Regarding indirect associations, many studies link indoor dampness and microbiologic pollutants (primarily in homes) to asthma exacerbations and respiratory infections, which in turn have been related to reduced performance and attendance. Also, much evidence links poor IEQ (e.g. low ventilation rate, excess moisture, or formaldehyde) with adverse health effects in children and adults and documents dampness problems and inadequate ventilation as common in schools. Overall, evidence suggests that poor IEQ in schools is common and adversely influences the performance and attendance of students, primarily through health effects from indoor pollutants. Evidence is available to justify (i) immediate actions to assess and improve IEQ in schools and (ii) focused research to guide IEQ improvements in schools. PRACTICAL IMPLICATIONS: There is more justification now for improving IEQ in schools to reduce health risks to students than to reduce performance or attendance risks. However, as IEQ-performance links are likely to operate largely through effects of IEQ on health, IEQ improvements that benefit the health of students are likely to have performance and attendance benefits as well. Immediate actions are warranted in schools to prevent dampness problems, inadequate ventilation, and excess indoor exposures to substances such as NO(2) and formaldehyde. Also, siting of new schools in areas with lower outdoor pollutant levels is preferable.  相似文献   

18.
Jones R  Recer GM  Hwang SA  Lin S 《Indoor air》2011,21(2):156-164
Asthma is a leading chronic disease among children and places a significant burden on public health. Exposure to indoor mold has been associated with asthma symptoms. However, many mold assessments have relied on visual or other identification of damp conditions and mold presence, thus have not examined associations with specific fungal genera. The objective of this case-control study was to examine the relationship between airborne mold concentrations and asthma status among children and to identify the contribution from specific mold genera in air. Participants completed a questionnaire of home environmental conditions and underwent indoor air sampling in the home, from which viable and total-count fungal spores were quantified. The most prevalent fungi in the homes were the allergenic molds Cladosporium (98% and 87% of homes from viable and total count samples, respectively) and Penicillium (91% and 73%). There were no significant differences in mean fungal concentrations between the homes of cases and controls, although the observed rate of exposure to several molds was higher among the cases. Among children who lacked a family history of asthma, cases had significantly higher exposures to viable Aspergillus. Measured humidity levels in the home corresponded with some self-reported indicators of mold and dampness. PRACTICAL IMPLICATIONS: The results of this study support existing literature that indoor fungal exposures play a role in current asthma status and that some qualitative assessments of mold exposure correspond to fungi present in indoor air.  相似文献   

19.
Abstract The National Institute for Occupational Safety and Health investigated respiratory symptoms and asthma in relation to damp indoor environments in employees of two hospitals. A cluster of six work‐related asthma cases from one hospital department, whose symptoms arose during a time of significant water incursions, led us to conduct a survey of respiratory health in 1171/1834 employees working in the sentinel cases hospital and a nearby hospital without known indoor environmental concerns. We carried out observational assessment of dampness, air, chair, and floor dust sampling for biological contaminants, and investigation of exposure‐response associations for about 500 participants. Many participants with post‐hire onset asthma reported diagnosis dates in a period of water incursions and renovations. Post‐hire asthma and work‐related lower respiratory symptoms were positively associated with the dampness score. Work‐related lower respiratory symptoms showed monotonically increasing odds ratios with ergosterol, a marker of fungal biomass. Other fungal and bacterial indices, particle counts, cat allergen and latex allergen were associated with respiratory symptoms. Our data imply new‐onset of asthma in relation to water damage, and indicate that work‐related respiratory symptoms in hospital workers may be associated with diverse biological contaminants.  相似文献   

20.
This stratified cross-sectional epidemiological study included 1053 school children aged 13-17 years. All pupils filled in a questionnaire on building-related symptoms and other relevant health aspects. The following exposure measurements were carried out: room temperature, CO2 level, and relative humidity; building characteristics including mold infestation were assessed, and dust was collected from floors, air, and ventilation ducts during a working day. Dust was examined for endotoxin level, and cultivated for viable molds. We did not find a positive association between building-related symptoms and extent of moisture and mold growth in the school buildings. Five of eight building-related symptoms were significantly and positively associated with the concentration of colony forming units of molds in floor dust: eye irritation, throat irritation, headache, concentration problems, and dizziness. After adjusting for different potentially confounding factors in separate analyses of each symptom, the above-mentioned associations between molds in dust and symptoms were still present, except for concentration problems. However, in none of the analyses was mold exposure the strongest covariate, being secondary to either asthma, hay fever, recent airway infection, or psychosocial factors.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号