The airway irritation of a reaction mixture of R-(+)-limonene and ozone was evaluated by a mouse bioassay in which sensory irritation, bronchoconstriction and pulmonary irritation were measured. Significant sensory irritation (33% reduction of mean respiratory rate) was observed by dynamic exposure of the mice, during 30 min, to a ca. 16 s old reaction mixture of ozone and limonene. The initial concentrations were nominally 4 ppm O3 and 48 ppm limonene. After reaction, the residual O3 was <0.03 ppm. Conventional analytical chemical methods were used to measure the formation of readily identified and stable products. Besides the expected products, 1-methyl-4-acetylcyclohexene (AMCH), 3-isopropenyl-6-oxoheptanal (IPOH), formaldehyde and formic acid, autooxidation products of limonene and a series of compounds including acetone, acrolein and acetic acid, which may or may not be artefacts, were identified. Addition of the sensory irritation effects of the residual reactants and all the identified compounds could not explain the observed sensory irritation effect. This suggests that one or more strong airway irritants were formed. Since limonene is common in the indoor air, and ozone is infiltrated from outdoors and/or produced indoors (e.g., by photocopiers), such oxidation reactions may be relevant for indoor air quality.  相似文献   

2.
Exposure to airborne pollutants can result in adverse health effects. Acute symptoms can for instance comprise of irritation of the eyes or of the respiratory tract (called sensory irritation). In a recent case, health problems were reported in a French school and supposedly attributed to the presence of airborne irritant pollutants. Based on measured concentrations, the risk of developing the described health effects was assessed.Numerous airborne sensory irritants (aldehydes, organic acids, volatile organic compounds (VOCs), SO(2), NH(3)) were identified and quantified in the indoor air by using active and passive sampling and online monitoring techniques. Reference values based on toxicological properties of compounds (sensory irritants) were taken from the literature. If not available, tentative values were specially developed for this purpose. Concentrations of all sensory irritants remain below their corresponding guideline values and are comparable to literature data. It was concluded that the risk of developing sensory irritation due to the presence of the studied compounds is negligible. This holds both for individual compounds and for the mixture of studied compounds. Limitations of the employed sampling strategy, and of existing sampling and analytical techniques, which do not allow for analysing more reactive compounds-which are strong sensory irritants-may play a role. New sampling techniques need to be developed. Psychosocial factors (group behaviour, increased attention to sensory irritation) should also be taken into account when dealing with health complaints on sensory irritation.  相似文献   

3.
Dry and irritated mucous membranes of the eyes and airways are common symptoms reported in office-like environments. Earlier studies suggested that indoor pollutants were responsible. We have re-evaluated, by review of the literature, how low relative humidity (RH) may influence the immediately perceived indoor air quality (IAQ), including odour, and cause irritation symptoms (i.e. longer-term perceived IAQ). "Relative humidity" were searched in major databases, and combined with: air quality, cabin air, dry eyes, formaldehyde, inflammation, mucous membranes, offices, ozone, pungency, sensory irritation, particles, precorneal tear film, sick building syndrome, stuffy air, and VOCs. The impact of RH on the immediately and longer-term perceived IAQ by VOCs, ozone, and particles is complex, because both the thermodynamic condition and the emission characteristics of building materials are influenced. Epidemiological, clinical, and human exposure studies indicate that low RH plays a role in the increase of reporting eye irritation symptoms and alteration of the precorneal tear film. These effects may be exacerbated during visual display unit work. The recommendation that IAQ should be "dry and cool" may be useful for evaluation of the immediately perceived IAQ in material emission testing, but should be considered cautiously about the development of irritation symptoms in eyes and upper airways during a workday. Studies indicate that RH about 40% is better for the eyes and upper airways than levels below 30%. The optimal RH may differ for the eyes and the airways regarding desiccation of the mucous membranes.  相似文献   

4.
The indoor and outdoor air quality of two staff quarters of Hong Kong Polytechnic University at Tsim Sha Tsui East (TSTE) and Shatin (ST) were investigated. The air sampling was carried out in winter for about two months starting from January to February of 1996. Fifteen flats from each staff quarter were randomly selected for indoor/outdoor air pollutant measurements. The pollutants measured were NOx, NO, NO2, SO2, CO, and O3. The variations of pollutant concentrations between indoor and outdoor air were investigated on weekday mornings, weekday evenings, weekend mornings, and weekend evenings. All indoor/outdoor pollutant concentrations measured did not exceed the ASHRAE/NAAQS standard. The carbon monoxide concentrations indoors were systemically higher than those outdoors at the TSTE and the ST quarters, both on weekdays and Sunday, which indicates there are CO sources indoors. Except for CO, the indoor levels of other pollutants (NOx, NO, NO2, SO2, and O3) are lower than those outdoors. There was a significant correlation (P < 0.05) between indoor and outdoor concentrations for SO2 and O3 at both the TSTE and the ST quarters. Except for O3, the mean concentrations of all the pollutants in the TSTE quarters, both indoor and outdoor, were higher than that of the ST quarters in all sampling periods. All indoor and outdoor O3 levels were lower at the TSTE quarters than those at the ST quarters. The O3 ratios of TSTE/ST were 0.72 outdoor and 0.79 indoor. This can be explained by the NO titration reaction through NO conversion to NO2.  相似文献   

5.
Sensory effects in eyes and airways are common symptoms reported by aircraft crew and office workers. Neurological symptoms, such as headache, have also been reported. To assess the commonality and differences in exposures and health symptoms, a literature search of aircraft cabin and office air concentrations of non-reactive volatile organic compounds (VOCs) and ozone-initiated terpene reaction products were compiled and assessed. Data for tricresyl phosphates, in particular tri-ortho-cresyl phosphate (ToCP), were also compiled, as well as information on other risk factors such as low relative humidity.A conservative health risk assessment for eye, airway and neurological effects was undertaken based on a “worst-case scenario” which assumed a simultaneous constant exposure for 8 h to identified maximum concentrations in aircraft and offices. This used guidelines and reference values for sensory irritation for eyes and upper airways and airflow limitation; a tolerable daily intake value was used for ToCP. The assessment involved the use of hazard quotients or indexes, defined as the summed ratio(s) (%) of compound concentration(s) divided by their guideline value(s).The concentration data suggest that, under the assumption of a conservative “worst-case scenario”, aircraft air and office concentrations of the compounds in question are not likely to be associated with sensory symptoms in eyes and airways. This is supported by the fact that maximum concentrations are, in general, associated with infrequent incidents and brief exposures. Sensory symptoms, in particular in eyes, appear to be exacerbated by environmental and occupational conditions that differ in aircraft and offices, e.g., ozone incidents, low relative humidity, low cabin pressure, and visual display unit work. The data do not support airflow limitation effects. For ToCP, in view of the conservative approach adopted here and the rareness of reported incidents, the health risk of exposure to this compound in aircraft is considered negligible.  相似文献   

6.
This paper presents an assessment of air quality of the city Eskişehir, located 230 km southwest to the capital of Turkey. Only five of the major air pollutants, most studied worldwide and available for the region, were considered for the assessment. Available sulphur dioxide (SO2), particulate matter (PM), nitrogen dioxide (NO2), ozone (O3), and non-methane volatile organic carbons (NMVOCs) data from local emission inventory studies provided relative source contributions of the selected pollutants to the region.The contributions of these typical pollution parameters, selected for characterizing such an urban atmosphere, were compared with the data established for other cities in the nation and world countries. Additionally, regional ambient SO2 and PM concentrations, determined by semi-automatic monitoring at two sites, were gathered from the National Ambient Air Monitoring Network (NAAMN). Regional data for ambient NO2 (as a precursor of ozone as VOCs) and ozone concentrations, through the application of the passive sampling method, were provided by the still ongoing local air quality monitoring studies conducted at six different sites, as representatives of either the traffic-dense-, or coal/natural gas burning residential-, or industrial/rural-localities of the city. Passively sampled ozone data at a single rural site were also verified with the data from a continuous automatic ozone monitoring system located at that site. Effects of variations in seasonal-activities, newly established railway system, and switching to natural gas usage on the temporal changes of air quality were all considered for the assessment. Based on the comparisons with the national [AQCR (Air Quality Control Regulation). Ministry of Environment (MOE), Ankara. Official Newspaper 19269; 1986.] and a number of international [WHO (World Health Organization). Guidelines for Air Quality. Geneva; 2000. Downloaded in January 2006, website: http://www.who.int/peh/; EU (European Union). Council Directive 1999/30/EC relating to limit values for sulfur dioxide, nitrogen dioxide and lead in ambient air. Of J Eur Communities L 163: 14–30; 29.6.1999; EU (European Union). Council Directive 2002/3/EC relating to ozone in ambient air. Of J Eur Communities. L 67: 14–30; 9.3.2002.; USEPA (U.S. Environmental Protection Agency). National Ambient Air Quality Standards (NAAQS). Downloaded in January 2006, website: http://www.epa.gov/ttn/naaqs/] ambient air standards, among all the pollutants studied, only the annual average SO2 concentration was found to exceed one specific limit value (EU limit for protection of the ecosystem). A part of the data (VOC/NOx ratio), for determining the effects of photochemical interactions, indicated that VOC-limited regime was prevailing throughout the city.  相似文献   

7.
The effect of ozone in a chemical sludge disintegration process was evaluated. Sludge solution chemical oxygen demand (COD), total suspended solids (TSS) and settling were investigated in single and sequential processes. A significant influence of ozone dose on sludge disintegration was observed: ozone was utilised to degrade the soluble organic matter and to destroy cell surfaces and release the cell liquids. For a single ozonation step, we found an optimum ozone dose in the range of 0.008–0.013 g O3/g TSS to give the best COD and TSS removal efficiency. Disintegrated sludge was treated in a sequential process consisting of consecutive ozonation and bio-aeration (i.e. O3 + biological treatment). The tendency was dependent on accumulated ozone, treatment time and operational conditions. An accumulated ozone dose of 0.055 g O3/g TSS in two separate ozonation processes followed by biological treatments led to COD and TSS removal efficiency of 53 and 46.6%, respectively. The removal efficiency was improved by increasing aerobic treatment time and/or by mixing ozonated sludge with non-ozonated sludge. The settling ability of sludge was found to be fast at very low specific ozone doses. An observed tendency was the effect of ozone on cell disintegration and protein liberation. The use of sequential processes improved the settling tendency of sludge.  相似文献   

8.
Long-term air quality data with high temporal and spatial resolutions are needed to understand some important processes affecting the air quality and corresponding environmental and health effects. The annual and diurnal variations of each criteria pollutant including PM2.5 and PM10 (particulate matter with aerodynamic diameter less than 2.5 μm and 10 μm, respectively), CO (carbon monoxide), NO2 (nitrogen dioxide), SO2 (sulfur dioxide) and O3 (ozone) in 31 provincial capital cities between April 2014 and March 2015 were investigated by cluster analysis to evaluate current air pollution situations in China, and the cities were classified as severely, moderately, and slightly polluted cities according to the variations. The concentrations of air pollutants in winter months were significantly higher than those in other months with the exception of O3, and the cities with the highest CO and SO2 concentrations were located in northern China. The annual variation of PM2.5 concentrations in northern cities was bimodal with comparable peaks in October 2014 and January 2015, while that in southern China was unobvious with slightly high PM2.5 concentrations in winter months. The concentrations of particulate matter and trace gases from primary emissions (SO2 and CO) and NO2 were low in the afternoon (~ 16:00), while diurnal variation of O3 concentrations was opposite to that of other pollutants with the highest values in the afternoon. The most polluted cities were mainly located in North China Plain, while slightly polluted cities mostly focus on southern China and the cities with high altitude such as Lasa. This study provides a basis for the formulation of future urban air pollution control measures in China.  相似文献   

9.
Eye irritation symptoms, e.g. dry eyes, are common and abundant symptoms reported in office-like environments, e.g. aircraft cabins. To improve the understanding of indoor related eye symptomatology, relevant knowledge from the ophthalmological and indoor environmental science literature has been merged. A number of environmental (relative humidity, temperature, draft), occupational (e.g. visual display unit work), and individual (e.g. gender, use of cosmetics, and medication) risk factors have been identified, which are associated with alteration of the precorneal tear film (PTF); these factors may subsequently exacerbate development of eye irritation symptoms by desiccation. Low relative humidity including reduced atmospheric pressure further increases the water evaporation from an altered PTF; in addition, work with visual display units may destabilize the PTF by lower eye blink frequency and larger ocular surface. Results from epidemiological and clinical studies support that relative humidity >40% is beneficial for the PTF. Only few pollutants reach high enough indoor concentrations to cause sensory irritation of the eyes, while an altered PTF may exacerbate their sensory effect. Sustained low relative humidity causes impairment of the PTF, while its stability, including work performance, is retained by low gaze and intermittent breaks.  相似文献   

10.
On 15 dates, 5000 measurements of carbon monoxide (CO) were made in downtown commercial settings in four California towns and cities (San Francisco, Palo Alto, Mountain View, and Los Angeles), using personal exposure monitoring (PEM) instruments. Altogether, 588 different commercial settings were visited, and indoor and outdoor locations were sampled at each setting. On 11 surveys, two CO PEM's were carried about 0.15–6 m apart, giving 1706 pairs of observations that showed good agreement: the correlation coefficient was r = 0.97 or greater, and the average difference was less than 1 ppm (μL/L) by volume. Of 210 indoor settings (excluding parking garages), 204 (97.1%) had average CO concentrations less than 9 ppm (μL/L); of 368 outdoor settings, 356 (96.7%) had average CO concentrations less than 9 ppm (μL/L). For a given date and commercial setting, CO concentrations were found to be relatively stable over time, permitting levels to be characterized by making only brief visits to each setting. The data indicate that most commercial settings experience CO concentrations above zero indoors, because CO tends to seep into buildings from vehicular emissions outside. Levels in these locations usually are not above 5 ppm (μL/L) and seldom are higher than the U.S. health-related ambient air quality standards for CO. However, indoor garages and buildings with attached indoor parking areas are exceptions and can experience relatively high CO concentrations.  相似文献   

11.
Since the air pollution as measured by stationary monitoring stations is a poor indicator of the population exposure, personal monitors are indispensible to health effects studies. This article reviews the current research on the development of personal monitors. Although most of the analytical methods reviewed in this study appear to be sensitive to the levels of the target pollutants NO2, SO2, and O3 generally encountered in indoor and outdoor air, they lack the desired performance characteristics for a personal monitoring device, such as user safety and ease of operation, weight, and maintenance. Electrochemical transducers/sensors, which have not yet been exploited, are attractive candidates for the application to personal monitoring. This technique has an added feature of generating real-time measurements. A few research models and commercially attractive devices that can be used in field studies are included.  相似文献   

12.
This paper describes the historical development and current legislation to control photochemical oxidant pollution in OECD countries. Policies for implementing, attaining, and maintaining ambient air quality standards or goals are discussed, problems associated with the various steps are highlighted, and the possibility of international policy guidelines which could control pollution across national frontiers is considered. To date, only a few countries have formulated ambient air quality standards for ozone/ oxidants; these standards are usually short-term averages over 1 h, ranging from 0.06 ppm (μL/L) in Japan to 0.12 ppm (μL/L) in the United States. The current interest in air quality management on an international scale leads to the conclusion that successful control of photochemical oxidant pollution would be best accomplished through the establishment of internationally acceptable standards or goals for oxidants/ozone based on health effects and other relevant environmental impacts, in combination with control strategies developed and implemented on an international level.  相似文献   

13.
For buildings in which the emissions from people is the main source of pollution, the number of people is the limiting factor for air ventilation. When such buildings are not used at full capacity, the ventilation, and consequently the energy consumption, is unnecessarily high. A great deal of the energy could be saved if the ventilation system could be developed to adjust the air flow to the actual requirements. One possible system would allow the amount of CO2 in the exhaust air to control the ventilation rate. To study if this principle is practicable and economic, a CO2 indicator has been installed in an office building in Helsinki. The mixture of exterior air and recirculated air is adjusted so that the amount of CO2 during working hours is kept on ca 700 ppm (μL/L). The equipment was used during winter 1981-82, and the variation of CO2 and the exterior air flow has been registered. The proportion of CO2 has also been measured locally in order to study occasional variations that may occur. The proportion of other pollutants in the room air has been studied simultaneously with a gas chromatograph. Different types of CO2 indicators were used to study the efficiency of the control system. The successful results indicate that the system can be used in new constructions, as well as in existing buildings.  相似文献   

14.
Both the World Health Organization and the UK Expert Panel on Air Quality Standards (EPAQS) have considered benzo(a)pyrene (BaP) as a marker of the carcinogenic potency of the polycyclic aromatic hydrocarbons (PAH) mixture, when recommending their respective guidelines for PAHs in outdoor air. The aim of this research is to compare the concentrations and relative abundance of individual PAH and their contribution to the overall carcinogenic potential of the PAH mixture in indoor and outdoor environments to assess the suitability of the UK air quality standard derived for outdoor air for use as a guideline for indoor environments. Samples were collected onto filters using active sampling in different indoor and outdoor microenvironments. The ratio of individual compounds to BaP, the BaP equivalent concentrations and the percentage contribution of each individual compound to the total carcinogenic potential of the PAH mixture were calculated. Mean concentrations were generally lower indoors (BaP=0.10 ng/m(3)) than outdoors (BaP=0.19 ng/m(3)), with the exception of indoor environments with wood burners (BaP=2.4 ng/m(3)) or ETS (BaP=0.6 ng/m(3)). The ratio of individual PAHs to BaP showed no significant differences between indoors (e.g. DahA/BaP=0.27) and outdoors (DahA/BaP=0.31). The relative contribution of BaP to the PAH overall carcinogenic potency is similar indoors (49%), outdoors (54%) and in the smelter environment (48%) used by EPAQS to derive the UK Air Quality Standard for ambient air. These results suggest the suitability of BaP as a marker for the carcinogenic potential of the PAH mixture irrespective of the environment. Despite small differences in PAH mixture composition indoors and outdoors, the level of protection afforded by the present EPAQS standard is likely to be similar whether it is applied to indoor or outdoor air.  相似文献   

15.
A sample of 58 occupied homes in Rochester, NY, most of which incorporated special builder-designed weatherization components, were studied to assess (1) the effectiveness of construction techniques designed to reduce air leakage; (2) the indoor air quality and air-exchange rates in selected airtight houses, and (3) the impact on indoor air quality of mechanical ventilation systems employing air-to-air heat exchangers. The “specific leakage area” was measured in each house using the fan pressurization technique. Houses built with polyethylene vapor barriers and joint-sealing were as a group 50% tighter than a similar group of houses without such components. Mechanical ventilation systems with air-to-air heat exchangers were installed in nine relatively airtight houses, some of which had gas stoves and/or tobacco smoking occupants. Air-exchange rates and indoor concentrations of radon (Rn), formaldehyde (HCHO), nitrogen dioxide (NO2), and humidity were measured in each house for 1-week periods with and without mechanical ventilation. More detailed measurements, including concentrations of carbon monoxide and inhalable particulates, were made in two of these houses by a mobile laboratory. In all nine houses, air-exchange rates were relatively low (0.2–0.5 ach) without mechanical ventilation, and yet indoor concentrations of Rn, HCHO, and NO2 were below existing guidelines. Mechanical ventilation systems were effective in further reducing indoor contaminant concentrations. We conclude that when contaminant source strengths are low, acceptable indoor air quality can be compatible with low air-exchange rates.  相似文献   

16.
Given the shrinking spatial contrasts in outdoor air pollution in Switzerland and the trends toward tightly insulated buildings, the Swiss Cohort Study on Air Pollution and Lung and Heart Diseases in Adults (SAPALDIA) needs to understand to what extent outdoor air pollution remains a determinant for residential indoor exposure. The objectives of this paper are to identify determining factors for indoor air pollution concentrations of particulate matter (PM), ultrafine particles in the size range from 15 to 300 nm, black smoke measured as light absorbance of PM (PMabsorbance) and nitrogen dioxide (NO2) and to develop predictive indoor models for SAPALDIA. Multivariable regression models were developed based on indoor and outdoor measurements among homes of selected SAPALDIA participants in three urban (Basel, Geneva, Lugano) and one rural region (Wald ZH) in Switzerland, various home characteristics and reported indoor sources such as cooking. Outdoor levels of air pollutants were important predictors for indoor air pollutants, except for the coarse particle fraction. The fractions of outdoor concentrations infiltrating indoors were between 30% and 66%, the highest one was observed for PMabsorbance. A modifying effect of open windows was found for NO2 and the ultrafine particle number concentration. Cooking was associated with increased particle and NO2 levels. This study shows that outdoor air pollution remains an important determinant of residential indoor air pollution in Switzerland.  相似文献   

17.
Human exposure to ambient ozone (O3) has been linked to a variety of adverse health effects. The ozone level at a location is contributed by local production, regional transport, and background ozone. This study combines detailed emission inventory, air quality modeling, and census data to investigate the source–receptor relationships between nitrogen oxides (NOx) emissions and population exposure to ambient O3 in 48 states over the continental United States. By removing NOx emissions from each state one at a time, we calculate the change in O3 exposures by examining the difference between the base and the sensitivity simulations. Based on the 49 simulations, we construct state-level and census region-level source–receptor matrices describing the relationships among these states/regions. We find that, for 43 receptor states, cumulative NOx emissions from upwind states contribute more to O3 exposures than the state's own emissions. In-state emissions are responsible for less than 15% of O3 exposures in 90% of U.S. states. A state's NOx emissions can influence 2 to 40 downwind states by at least a 0.1 ppbv change in population-averaged O3 exposure. The results suggest that the U.S. generally needs a regional strategy to effectively reduce O3 exposures. But the current regional emission control program in the U.S. is a cap-and-trade program that assumes the marginal damage of every ton of NOx is equal. In this study, the average O3 exposures caused by one ton of NOx emissions ranges from ? 2.0 to 2.3 ppm-people-hours depending on the state. The actual damage caused by one ton of NOx emissions varies considerably over space.  相似文献   

18.
A sex-linked recessive lethal test was performed on male fruit flies of the species Drosophila melanogaster, (Oregon-R strain), exposed to an approximate five-fold dilution of exhaust from a diesel engine. The eight hour exposure was achieved by drawing diluted diesel exhaust from a three cubic meter stainless steel exposure chamber housing laboratory animals through a two liter reaction flask modified for use with Drosophila. A preconditioned sampling bag was used to collect the emissions after passing through the exposure chamber containing the flies. Results of analyses performed on the diesel exhaust mixture showed the following: carbon dioxide—0.17%, carbon monoxide—12.2 ppm, hydrocarbons—11.6 ppm, nitrogen oxide—3.8 ppm, nitrogen dioxide—2.9 ppm, sulphur dioxide—1.0 ppm, and particulates—2.18 mg/m3. Two broods of the F2 generation were investigated for the occurrence of recessive lethal events. These broods approximated the developing gametogenic stages of mature sperm (P1 matings on days 2 and 3 postexposure) and spermatocytes (P1 matings on days 8 and 9). Additionally, the F3 generation was evaluated for the occurrence of mosaic recessive lethal events which might escape detection in the F2 generation. An equal number of F2 and F3 flies for both broods served as concurrent controls. Results indicate that, under the conditions tested, the diesel exhaust did not increase the mutation frequency of the exposed flies (F2 rate = 0.30%, F3 rate = 0%) when compared to the concurrent controls (F2 rate = 0.37%, F3 rate = 0.15%).  相似文献   

19.
In the frame of the OFFICAIR project, indoor and outdoor PM2.5 samples were collected in office buildings across Europe in two sampling campaigns (summer and winter). The ability of the particles to deplete physiologically relevant antioxidants (ascorbic acid (AA), reduced glutathione (GSH)) in a synthetic respiratory tract lining fluid, i.e., oxidative potential (OP), was assessed. Furthermore, the link between particulate OP and the concentration of the PM constituents was investigated.The mean indoor PM2.5 mass concentration values were substantially lower than the related outdoor values with a mean indoor/outdoor PM2.5 mass concentration ratio of 0.62 and 0.61 for the summer and winter campaigns respectively. The OP of PM2.5 varied markedly across Europe with the highest outdoor OPAA m−3 and OPGSH m−3 (% antioxidant depletion/m3 air) values obtained for Hungary, while PM2.5 collected in Finland exhibited the lowest values. Seasonal variation could be observed for both indoor and outdoor OPAA m−3 and OPGSH m−3 with higher mean values during winter. The indoor/outdoor OPAA m−3 and OPGSH m−3 ratios were less than one with 4 and 17 exceptions out of the 40 cases respectively. These results indicate that indoor air is generally less oxidatively challenging than outdoors. Correlation analysis revealed that trace elements play an important role in determining OP, in particular, the Cu content. Indoor air chemistry might affect OP since weaker correlations were obtained for indoor PM2.5. Our findings also suggest that office workers may be exposed to health relevant PM constituents to a different extent within the same building.  相似文献   

20.
This paper summarizes recent data on the occurrence of major organic compounds (benzene, toluene, xylenes, styrene, acetaldehyde, formaldehyde, naphthalene, limonene, α-pinene and ammonia, classified by the European Commission's INDEX strategy report as the priority pollutants to be regulated) and evaluates accordingly cancer and non-cancer risks posed by indoor exposure in dwellings and public buildings in European Union (EU) countries. The review process indicated that significant differences in indoor air quality exist within and among the countries where data were available, indicating corresponding differences in sources and emission strength of airborne chemicals, identified or not. Conservative exposure limits were not exceeded for non-carcinogenic effects, except for formaldehyde; for carcinogenic agents the estimated risks were up to three orders of magnitude higher than the one (10(-6)) proposed as acceptable by risk management bodies. However, the risk assessment evaluation process faces crucial difficulties, either due to the relative paucity of indoor air quality measurements in many EU countries, or by the lack of sampling consistency in the already existing studies, indicating the need for additional measurements of indoor air quality following a harmonized sampling and analytical protocol. Additionally, uncertainties embodied in the cancer potency factors and exposure limit values impose further difficulties in substance prioritization and risk management.  相似文献   