首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A SBA‐15/polyaniline para‐toluenesulfonic acid nanocomposite supported micro‐solid‐phase extraction procedure has been developed for the extraction of parabens (methylparaben, ethylparaben, and propylparaben) from wastewater and cosmetic products. The variables of interest in the extraction process were pH of sample, sample and eluent volumes, sorbent amount, salting‐out effect, extraction and desorption time, and stirring rate. A Plackett–Burman design was performed for the screening of variables in order to determine the significant variables affecting the extraction efficiency. Then, the significant factors were optimized by using a central composite design. The optimum experimental conditions found at 50 mL sample solution, extraction and desorption times of 40 and 20 min, respectively, 500 μL of 3% v/v acetic acid in methanol as eluent, 0.01 M salt addition, and 10 mg of the sorbent. Under the optimum conditions, the developed method provided detection limits in the range of 0.08–0.4 ng/mL with good repeatability (RSD% < 7) and linearity (r2 = 0.997–0.999) for the three parabens. Finally, this fast and efficient method was employed for the determination of target analytes in cosmetic products and wastewater, and satisfactory results were obtained.  相似文献   

2.
A micro‐SPE technique was developed by fabricating a rather small package including a polypropylene membrane shield containing the appropriate sorbent. The package was used for the extraction of some triazine herbicides from aqueous samples. Solvent desorption was subsequently performed in a microvial and an aliquot of extractant was injected into GC‐MS. Various sorbents including aniline‐ortho‐phenylene diamine copolymer, newly synthesized, polypyrrole, multiwall carbon nanotube, C18 and charcoal were examined as extracting media. Among them, conductive polymers exhibited better performance. Influential parameters including extraction and desorption time, desorption solvent and the ionic strength were optimized. The developed method proved to be rather convenient and offers sufficient sensitivity and good reproducibility. The detection limits of the method under optimized conditions were in the range of 0.01–0.04 ng/mL. The RSDs at a concentration level of 0.1 ng/mL were obtained between 4.5 and 9.3% (n=5). The calibration curves of analytes showed linearity in the range of 0.05–10 ng/mL. The developed method was successfully applied to the extraction of selected triazines from real water samples. The whole procedure showed to be conveniently applicable and quite easy to manipulate.  相似文献   

3.
A rapid micro‐analytical multiresidue method was developed for analysis of pyrethroids (kadethrin K, cypermethrin C and permethrin P) in soil micro‐sample (200 mg). It uses on‐line flow‐through extraction of soil micro‐samples (packed into a short glass column) with a methanol‐aqueous citric acid buffer mixture, successive on‐line SPE preconcentration of analytes from the extract and on‐line RP‐HPLC analysis with UV photometric detection. The separation of pyrethroids is performed on a Purospher RP‐18e column with methanol/water as mobile phase. Effects of sorbent placed at the bottom of a short column holding the soil sample and different kinds of on‐line SPE columns were tested. Besides, the influence of volume of the effluent on the pyrethroids recovery was also studied. Calibration curves were linear over the range assayed from 0.01 to 0.2 μg/mL with correlation coefficients of linear regression (least‐squares method) in the range 0.998–0.999. Recovery studies were carried out at 0.25–1.00 μg/g dry soil fortification level and obtained recoveries were for K 81–84%, C 56–59% and for P 58–63%. Achieved LOD (confidence band) of studied pyrethroids were for large‐volume injection (1 mL) 4.5 ng K, 3.7 ng C, 3.6 ng P or 27 ng/g K, 32 ng/g C and 29 ng/g P in dry soil “solid sampling HPLC”.  相似文献   

4.
A new sol–gel hybrid methyltrimethoxysilane‐chloropropyltriethoxysilane was prepared as sorbent for solid‐phase extraction. The extraction efficiency of the prepared sol–gel hybrid methyltrimethoxysilane‐chloropropyltriethoxysilane was assessed by using three selected organophosphorus pesticides, namely, chlorpyrifos, profenofos, and malathion. Gas chromatography–mass spectrometry was used for detection of organophosphorus pesticides. Several vital parameters were optimized to identify the best extraction conditions. Under the optimum extraction conditions, solid‐phase extraction‐methyltrimethoxysilane‐chloropropyltriethoxysilane method showed good linearity range (0.05‐1 μg/mL) with coefficient of determination more than 0.995. The limits of detection obtained were in the range of 0.01–0.07 μg/mL and limits of quantification ranging from 0.03 to 0.21 μg/mL. The limits of detection obtained for the developed method were 2.3–6.5× lower than the limits of detection of commercial octadecyl silica sorbent. Real samples analysis was carried out by applying the developed method on red apple and purple grape samples. The developed method exhibited good recoveries (88.33–120.7%) with low relative standard deviations ranging from 1.6 to 3.3% compared to commercial octadecyl silica sorbent, which showed acceptable recoveries (70.3–100.2%) and relative standard deviations (6.3–8.8%). The solid‐phase extraction‐methyltrimethoxysilane‐chloropropyltriethoxysilane method is presented as an alternative extraction method for determination of organophosphorus pesticides.  相似文献   

5.
Here, task‐specific ionic liquid solid‐phase extraction is proposed for the first time. In this approach, a thiourea‐functionalized ionic liquid is immobilized on the solid sorbent, multiwalled carbon nanotubes. These modified nanotubes packed into a solid‐phase extraction column are used for the selective extraction and preconcentration of ultra‐trace amounts of lead(II) from aqueous samples prior to electrothermal atomic absorption spectroscopy determination. The thiourea functional groups act as chelating agents for lead ions retaining them and so, give the selectivity to the sorbent. Elution of the retained ions can be performed using an acidic thiourea solution. The effects of experimental parameters including pH of the aqueous solution, type and amount of eluent, and the flow rates of sample and eluent solutions on the separation efficiency are investigated. The linear dependence of absorbance of lead on its concentration in the initial solution is in the range of 0.5–40.0 ng/mL with the detection limit of 0.13 ng/mL (3sb/m, n = 10). The proposed method is applicable to the analysis of red lipstick, pine leaves, and water samples for their lead contents.  相似文献   

6.
Chitosan‐grafted polyaniline was synthesized and applied as a sorbent for the preconcentration of phthalate esters in dispersive solid‐phase extraction. By coupling dispersive solid‐phase extraction with high‐performance liquid chromatography and response surface methodology (central composite design), a reliable, sensitive, and cost‐effective method for simultaneous determination of phthalate esters including dimethyl phthalate, di‐n‐butyl phthalate, and di(2‐ethylhexyl)phthalate was developed. The morphology of sorbent had been studied by scanning electron microscopy and its chemical structure confirmed by Fourier transform infrared spectroscopy. Under optimum condition, good linearity was observed in the range of 5.0–5000.0 ng/mL. The limits of detection (S/N = 3) and limits of quantification (S/N = 10) were 0.1–0.3 and 0.3–1 ng/mL, respectively. The relative standard deviations were less than 8.8%. Finally, this procedure was employed for extraction of trace amounts of phthalic acid esters in milk samples, the relative recoveries ranged from 82 to 103%.  相似文献   

7.
An iron‐embedded porous carbon material (MIL‐53‐C) was fabricated by the direct carbonization of MIL‐53. The MIL‐53‐C possesses a high surface area and good magnetic behavior. The structure, morphology, magnetic property, and porosity of the MIL‐53‐C were studied by scanning electron microscopy, transmission electron microscopy, vibrating sample magnetometry, and N2 adsorption. With the use of MIL‐53‐C as the magnetic solid‐phase extraction adsorbent, a simple and efficient method was developed for the magnetic solid‐phase extraction of three hormones from water and human urine samples before high‐performance liquid chromatography with UV detection. The developed method exhibits a good linear response in the range of 0.02–100 ng/mL for water and 0.5–100 ng/mL for human urine samples , respectively. The limit of detection (S/N = 3) for the analytes was 0.005–0.01 ng/mL for water sample and 0.1–0.3 ng/mL for human urine sample. The limit of quantification (S/N = 10) of the analytes were in the range of 0.015–0.030 and 0.3–0.9 ng/mL, respectively.  相似文献   

8.
A novel design of hollow‐fiber liquid‐phase microextraction containing multiwalled carbon nanotubes as a solid sorbent, which is immobilized in the pore and lumen of hollow fiber by the sol–gel technique, was developed for the pre‐concentration and determination of polycyclic aromatic hydrocarbons in environmental water samples. The proposed method utilized both solid‐ and liquid‐phase microextraction media. Parameters that affect the extraction of polycyclic aromatic hydrocarbons were optimized in two successive steps as follows. Firstly, a methodology based on a quarter factorial design was used to choose the significant variables. Then, these significant factors were optimized utilizing central composite design. Under the optimized condition (extraction time = 25 min, amount of multiwalled carbon nanotubes = 78 mg, sample volume = 8 mL, and desorption time = 5 min), the calibration curves showed high linearity (R 2 = 0.99) in the range of 0.01–500 ng/mL and the limits of detection were in the range of 0.007–1.47 ng/mL. The obtained extraction recoveries for 10 ng/mL of polycyclic aromatic hydrocarbons standard solution were in the range of 85–92%. Replicating the experiment under these conditions five times gave relative standard deviations lower than 6%. Finally, the method was successfully applied for pre‐concentration and determination of polycyclic aromatic hydrocarbons in environmental water samples.  相似文献   

9.
A solid‐phase nanoextraction method has been developed for the extraction and preconcentration of polychlorinated biphenyls using carboxyl multiwalled carbon nanotubes as a solid nano‐sorbent. Parameters affecting extraction efficiency such as sorbent amount, desorption solvent type and volume, extraction time, pH, and salt content have been studied. Under optimized conditions, the correlation coefficient was up to 0.9989, the limits of detection was in the range of 1.4–3.5 ng/L, and limits of quantification was between 4.8 and 11.6 ng/L. The recoveries were in the range of 99–106% for different spiked analytes. The relative standard deviation for water samples spiked with two different spiking levels has been between 4 and 10%. The proposed sustainable method is rapid, easy to use, and small consumption of organic solvent for the detection and determination of trace levels of polychlorinated biphenyls in environmental waters.  相似文献   

10.
Diallyldimethylammonium chloride modified magnetic nanoparticles were synthesized by the “thiol‐ene” click chemistry reaction. Diallyldimethylammonium chloride rendered the material plenty of quaternary ammonium groups, and thus the excellent aqueous dispersibility and anion‐exchange capability. The novel material was then used as the magnetic solid‐phase extraction sorbent to extract eight non‐steroidal anti‐inflammatory drugs from water samples. Combined with high‐performance liquid chromatography and ultraviolet detection, under the optimal conditions, the developed method exhibited wide linearity ranges (1–1000, 2–1000, and 5–1000 ng/mL) with recoveries of 88.0–108.6% and low limits of detection (0.3–1.5 ng/mL). Acceptable precision was obtained with satisfactory intra‐ and inter‐day relative standard deviations of 0.4–4.4% (= 3) and 1.1–5.5% (= 3), respectively. Batch‐to‐batch reproducibility was acceptable with relative standard deviations <9.7%. The hydrophilic magnetic nanoparticle featured with quaternary ammonium groups showed high analytical potential for acidic analytes in environmental water samples.  相似文献   

11.
The determination of 15 pyrethroids in soil and water samples was carried out by gas chromatography with mass spectrometry. Compounds were extracted from the soil samples (4 g) using solid–liquid extraction and then salting‐out assisted liquid–liquid extraction. The acetonitrile phase obtained (0.8 mL) was used as a dispersant solvent, to which 75 μL of chloroform was added as an extractant solvent, submitting the mixture to dispersive liquid–liquid microextraction. For the analysis of water samples (40 mL), magnetic solid‐phase extraction was performed using nanocomposites of magnetic nanoparticles and multiwalled carbon nanotubes as sorbent material (10 mg). The mixture was shaken for 45 min at room temperature before separation with a magnet and desorption with 3 mL of acetone using ultrasounds for 5 min. The solvent was evaporated and reconstituted with 100 μL acetonitrile before injection. Matrix‐matched calibration is recommended for quantification of soil samples, while water samples can be quantified by standards calibration. The limits of detection were in the range of 0.03–0.5 ng/g (soil) and 0.09–0.24 ng/mL (water), depending on the analyte. The analyzed environmental samples did not contain the studied pyrethroids, at least above the corresponding limits of detection.  相似文献   

12.
Magnetite nanoparticles incorporated into alginate beads and coated with a polypyrrole adsorbent were prepared (polypyrrole/Fe3O4/alginate bead) and used as an effective magnetic solid‐phase extraction sorbent for the extraction and enrichment of endocrine‐disrupting compounds (estriol, β‐estradiol and bisphenol A) in water samples. The determination of the extracted endocrine‐disrupting compounds was performed using high‐performance liquid chromatography with a fluorescence detector. The effect of various parameters on the extraction efficiency of endocrine disrupting compounds were investigated and optimized including the type and amount of sorbent, sample pH, extraction time, stirring speed, and desorption conditions. Under optimum conditions, the calibration curves were linear in the concentration range of 0.5–100.0 μg/L, and the limit of detection was 0.5 μg/L. The developed method showed a high extraction efficiency, the recoveries were in the range of 90.5 ± 4.1 to 98.2 ± 5.5%. The developed sorbent was easy to prepare, was cost‐effective, robust, and provided a good reproducibility (RSDs < 5%), and could be reused 16 times. The developed method was successfully applied for the determination of endocrine‐disrupting compounds in water samples.  相似文献   

13.
In this work, a magnetic metal–organic framework designated as MIL‐100(Fe) was prepared and applied as a magnetic solid‐phase extraction sorbent for the determination of trace polycyclic aromatic hydrocarbons in environmental water samples by coupling with high‐performance liquid chromatography and fluorescence detection. The magnetic microspheres exhibited large surface areas and high extraction ability, making them excellent candidates as sorbents for enrichment of trace polycyclic aromatic hydrocarbons. Under the optimized experimental conditions, good sensitivity levels were achieved with low detection limits ranging from 32 to 2110 pg/mL and good linearities with correlation coefficients higher than 0.9990 for the investigated 13 polycyclic aromatic hydrocarbons. The proposed method has been validated in the analysis of real water samples with mean recoveries in the range of 81.4–126.9% at four spiked levels and the relative standard deviations in the range of 1.3–17.0%. The magnetic MIL‐100(Fe) microspheres were stable enough for 150 extractions without a significant loss of extraction performance.  相似文献   

14.
Polyaniline coated cigarette filters were successfully synthesized and used as a solid‐phase extraction sorbent for the extraction and preconcentration of polycyclic aromatic hydrocarbons in water samples. The polyaniline helped to enhance the adsorption ability of polycyclic aromatic hydrocarbons on the sorbent through π–π interactions. The high porosity and large surface area of the cigarette filters helped to reduce backpressure and can be operated with high sample flow rate without loss of extraction efficiency. The developed sorbent was characterized by Fourier transform infrared spectroscopy and scanning electron microscopy. The parameters that affected the extraction efficiencies, i.e. polymerization time, type of desorption solvent and its volume, sample flow rate, sample volume, sample pH, ionic strength, and organic modifier were investigated. Under the optimal conditions, the method was linear over the range of 0.5–10 μg/L and a detection limit of 0.5 ng/L. This simple, rapid, and cost‐effective method was successfully applied to the preconcentration of polycyclic aromatic hydrocarbons from water samples. The developed method provided a high enrichment factor with good extraction efficiency (85–98%) and a relative standard deviation <10%.  相似文献   

15.
A solid‐phase microextraction (SPME) fiber coated with poly(methacrylic acid‐ethylene glycol dimethacrylate) coupled to GC with a micro electron‐capture detector was developed for the determination of four chlorphenols in water samples for the first time. A novel and simple method for the preparation of this novel SPME fiber was proposed by copolymerization of methacrylic acid and ethylene glycol dimethacrylate in an appropriate solvent using a glass capillary as a “mold”. The factors affecting the polymerization were optimized in detail. Furthermore, the extraction performance of the poly(methacrylic acid‐ethylene glycol dimethacrylate) fiber was evaluated. Moreover, experimental headspace‐SPME parameters, such as extraction temperature, extraction time, salt concentration, stirring speed, and pH, were optimized by orthogonal array experimental designs. Under the optimized conditions, the target analytes were linear in the range of 0.2–50 ng/mL, and the correlation coefficients were all greater than 0.99. RSD was less than 8.9%, and the detection limits were in the range of 0.1–10 ng/L. Four cholorphenols were detected from tap and lake water samples using the proposed method, with the recoveries of spiked natural water samples were ranged from 91.8 to 110.8, and 90.6 to 111.4% for tap and lake water samples, respectively.  相似文献   

16.
A novel metal‐ion‐mediated complex‐imprinted‐polymer‐coated solid‐phase microextraction (SPME) fiber used to specifically recognize thiabendazole (TBZ) in citrus and soil samples was developed. The complex‐imprinted polymer was introduced as a novel SPME coating using a “complex template” constructed with Cu(II) ions and TBZ. The recognition and enrichment properties of the coating in water were significantly improved based on the metal ion coordination interaction rather than relying on hydrogen bonding interactions that are commonly applied for the molecularly imprinting technique. Several parameters controlling the extraction performance of the complex‐imprinted‐polymer‐coated fiber were investigated including extraction solvent, pH value, extraction time, metal ion species, etc. Furthermore, SPME coupled with HPLC was developed for detection of TBZ, and the methods resulted in good linearity in the range of 10.0–150.0 ng/mL with a detection limit of 2.4 ng/mL. The proposed method was applied to the analysis of TBZ in spiked soil, orange, and lemon with recoveries of 80.0–86.9% and RSDs of 2.0–8.1%. This research provides an example to prepare a desirable water‐compatible and specifically selective SPME coating to extract target molecules from aqueous samples by introducing metal ions as the mediator.  相似文献   

17.
In this study, the suitability of solid‐phase extraction (SPE) coupled in‐line to CE with UV–Vis detection was evaluated for the preconcentration and separation of diluted solutions of five pharmaceuticals compounds: benzafibrate, piroxicam, diclofenac sodium, naproxen and clofibric acid. An SPE analyte concentrator containing Oasis® HLB sorbent was constructed without frits and placed near the inlet end of the separation capillary. Different parameters such as sample pH, composition and volume of the elution plug and sample loading time were studied in order to obtain the maximum preconcentration factors. The LODs reached for standard samples were in the range 0.06–0.5 ng/mL with good reproducibility, and the developed strategy provides sensitivity enhancement factors around 14 000‐fold in peak area and 5900‐fold in peak height compared with the normal hydrodynamic injection. Finally, river water samples fortified with the pharmaceutical compounds were analyzed by the developed in‐line SPE‐CE‐UV method in order to show the potential of the methodology for the analysis of environmental aquatic samples. For these samples, high values of relative recoveries, between 73–107% and 79–103% for two concentration levels, 5 and 25 ng/mL, respectively, were obtained and LODs ranged between 0.19 and 1 ng/mL.  相似文献   

18.
Using bamboo‐activated charcoal as SPE adsorbent, a novel SPE method was developed for the sensitive determination of tetrabromobisphenol A and bisphenol A in environmental water samples by rapid‐resolution LC‐ESI‐MS/MS. Important parameters influencing extraction efficiency, including type of eluent, eluent volume, sample pH, volume and flow rate, were investigated and optimized. Under the optimal extraction conditions (eluent: 8 mL methanol, pH: 7; flow rate: 4 mL/min; sample volume: 100 mL), low LODs (0.01–0.02 ng/mL), good repeatability (6.2–8.3%) and wide linearity range (0.10–10 ng/mL) were obtained. Satisfied results were achieved when the proposed method was applied to determine the two target compounds in real‐world environmental water samples with spiked recoveries over the range of 80.5–119.8%. All these facts indicate that trace determination of tetrabromobisphenol A and bisphenol A in real‐world environmental water samples can be realized by bamboo‐activated charcoal SPE‐rapid resolution‐LC‐ESI‐MS/MS.  相似文献   

19.
An efficient and sensitive analytical method based on molecularly imprinted solid‐phase extraction (MISPE) and reverse‐phase ultrasound‐assisted dispersive liquid–liquid microextraction (USA‐DLLME) coupled with LC–MS/MS detection was developed and validated for the analysis of urinary 4‐(methylnitrosamino)‐1‐(3‐pyridyl)‐1‐butanol (NNAL), a tobacco‐specific nitrosamine metabolite. The extraction performances of NNAL on three different solid‐phase extraction (SPE) sorbents including the hydrophilic‐lipophilic balanced sorbent HLB, the mixed mode cationic MCX sorbent and the molecularly imprinted polymers (MIP) sorbent were evaluated. Experimental results showed that the analyte was well retained with the highest extraction recovery and the optimum purification effect on MIP. Under the optimized conditions of MIP and USA‐DLLME, an enrichment factor of 23 was obtained. Good linearity relationship was obtained in the range of 5‐1200 pg/mL with a correlation coefficient of 0.9953. The limit of detection (LOD) was 0.35 pg/mL. The recoveries at three spiked levels ranged between 88.5% and 93.7%. Intra‐ and inter‐day relative standard deviations varied from 3.6% to 7.4% and from 5.4% to 9.7%, respectively. The developed method combing the advantages of MISPE and DLLME significantly improves the purification and enrichment of the analyte and can be used as an effective approach for the determination of ultra‐trace NNAL in complex biological matrices.  相似文献   

20.
A new micro‐solid‐phase extraction sorbent was synthesized by electrospinning poly(p‐phenylenediamine)/poly(vinyl alcohol) in the presence of cetyltrimethylammonium bromide. The modified nanofiber was prepared by removing the majority of the poly(vinyl alcohol) from the nanofiber blend by exposing it to the hot water. Scanning electron microscopy and surface analysis were performed to study the homogeneity and porosity of the electrospun nanofiber. In addition, Fourier transform infrared spectroscopy was applied for more characterization. The capability of the new nanofiber was explored by applying it in the extraction and preconcentration of organophosphorus pesticides from aqueous medium. After solvent desorption, the extracted analytes were analyzed by high‐performance liquid chromatography with diode array detection. Under the optimum conditions, the relative standard deviation values at the concentration level of 50 ng/mL were in the range of 4.8–8.3%. The calibration curve showed linearity in the range of 0.5–500 ng/mL, and the limits of detection (S/N = 3) for the studied compounds were 0.15 ng/mL. By analyzing Tehran drinking water, lemon juice, sour lemon juice, orange juice and sour orange juice, the applicability of the presented method was investigated and the relative recoveries were in the range of 76–102%.  相似文献   