1.
People working in the nickel refining industry are known to have a higher concentration of nickel in lung tissue than the general population. To be able to evaluate a potential nickel exposure from other sources, e.g., welding, it is important to have sufficient data on what is normal for a local population. Several local factors such as the content of nickel in air and soil can have a significant impact on this so-called normal value. As almost all surgical equipment contains nickel, the sampling process can in itself be a source of contamination. The scope of this work was to investigate if there was any measurable contamination from the sampling instruments routinely used in hospitals, and if the presence of a nickel refinery had any effect on the nickel content in the lungs of the general population. Autopsy lung tissue samples were collected in situ from 50 people who had lived in the county of Vest Agder in Norway. Two samples were collected from each person; one with a regular scalpel (Swann-Norton) and forceps, and one with a titanium knife and plastic forceps. None of the persons had any known connection to the nickel refinery. The samples were collected at random and no special attention was given to age, sex and place of residence. The autopsies were performed according to Norwegian law and in understanding with the next of kin. The arithmetic mean value +/- s of nickel was 0.64 +/- 0.56 microgram g-1 and 0.29 +/- 0.20 microgram g-1 dry weight, respectively, for samples collected with a regular scalpel and a titanium knife (P < 0.0001). For people who lived 8 km and closer to the refinery by the time of death, the nickel content was 0.41 +/- 0.19 microgram g-1 and for those who had lived between 8 and 70 km away from the refinery it was 0.18 +/- 0.13 microgram g-1 (P < 0.015). No statistical difference was established between results for males and females. Previous investigations have shown that the nickel content in lung tissue varies in the so-called normal population. This work has shown that factors such as sampling equipment and place of residence have an impact on the results. It thus demonstrates that reliable background values can presumably only be obtained by collecting samples from individuals not exposed to known environmental nickel sources and to use nickel-free instruments in the sampling process.  相似文献   

2.
The purpose of this study was to compare tanker drivers' occupational exposure level before and after the installation of vapour recovery facilities at 14 service stations. Road tanker drivers are exposed when handling volatile petrol liquid in bulk in the distribution chain. The drivers' exposure was studied during the unloading operation as the bulk petrol flowed into underground storage tanks, displacing vapours in the tank space and causing emission to the environment and the drivers' work area. The exposures were measured again when the dual point Stage I vapour recovery systems were installed for recycling vapours. Short-term measurements were carried out in the drivers' breathing zones by drawing polluted air through a charcoal tube during unloading. The samples were analysed in the laboratory by gas chromatography for C3-C11 aliphatic hydrocarbons, tert-butyl methyl ether (MTBE), tert-amyl methyl ether (MTAE), benzene, toluene and xylene. The road tanker loads delivered consisted of oxygenated and reformulated petrol (E95 and E98 brands), which contained on average 13% oxygenates. Before the installation of the vapour recovery system, the geometric mean (GM) concentration of aliphatic hydrocarbons was 65 mg m-3 (range 6-645 mg m-3) in the drivers' breathing zones. After the installation at the same service stations, the corresponding exposure level was 8.3 mg m-3 (range < 1-79 mg m-3). The GM of the MTBE concentrations was 8.6 mg m-3 (range 1-67 mg m-3) without vapour recovery and 1.5 mg m-3 (range < 0.1-10 mg m-3) with vapour recovery. The differences between the aliphatic hydrocarbons and the MTBE exposure levels during the unloading of the road tankers without and with vapour recovery were statistically significant (p < 0.05).  相似文献   

3.
A new method utilizing the diffusive sampling of formaldehyde in air has been developed. Formaldehyde is sampled with the use of a glass fiber filter impregnated with N-methyl-4-hydrazino-7-nitrobenzofurazan (MNBDH) and phosphoric acid. The formaldehyde hydrazone formed is desorbed from the filter with acetonitrile and determined by high-performance liquid chromatography (HPLC) with UV/visible detection at 474 nm. The sampling rate was determined to be 24.7 mL min-1 with a relative standard deviation of 7% for 48 experiments. The measured sampling rates were not dependent on the formaldehyde concentration (0.1-1.0 mg m-3), sampling time (15-482 min) or relative humidity (20-85%). The detection limit was 70 micrograms m-3 for a 15 min sampling period and 2 micrograms m-3 for an 8 h sampling period.  相似文献   

4.
Elder and poplar leaves from various sampling sites were studied with respect to their antimony content. Moreover, a retrospective determination of Sb was performed in representative limnic and terrestrial samples of the Federal Environmental Specimen Bank of Germany which have been collected over 14 years. The analytical procedure is based on an open vessel acid digestion of freeze-dried biological samples and the subsequent quantification of Sb in the digests by flow injection hydride generation atomic absorption spectrometry. Strict quality control schemes were applied to the entire procedure to guarantee accurate and precise results. No long-term changes of the Sb concentrations were found in spruce shoots or poplar leaves from different sampling sites. However, spruce shoots from a semi-natural region showed concentrations of Sb (approximately 22 ng g-1; range: 17-29 ng g-1) that were approximately four times lower than in corresponding samples from an urban-industrialized area. The analysis of virgin and washed elder leaves revealed that approximately 20-30% of the Sb is present on the leaf surface. Sb levels in elder leaves ranged from 5.2 +/- 0.3 ng g-1 in samples from Argentina to 589 +/- 30 ng g-1 in leaves collected directly beside a motorway in Germany. Similarly, poplar leaves from Argentina and Chile showed about 4 ng Sb g-1, whereas 150 ng Sb g-1 was found in poplar leaves from Germany. The lowest concentrations of Sb were determined in digests of pigeon eggs (approximately 2 ng g-1), bream liver (approximately 4 ng g-1) and deer liver (approximately 6 ng g-1). A similar pattern of Sb concentrations in spruce shoots, leaves or liver samples from an industrialized area and an agrarian ecosystem in Germany was established. Concentrations of Sb in elder leaves were closely associated with car traffic, giving maximum concentrations of 589 ng g-1 directly beside a motorway, 207 ng g-1 50 m from the motorway and 153 ng g-1 in a close residential area.  相似文献   

5.
采用毛细管柱气相色谱法测定环境空气中的1,2-二氯乙烷,用活性碳吸附,二硫化碳解析,FID检测器分析.方法在0 mg/L~311mg/L范围内线性良好,当采样体积为20 L时,最低检出质量浓度为0.006 mg/m3,标准溶液平行测定的RSD≤2.2%,加标回收率为98.4%~101%.  相似文献   

6.
气相色谱-质谱法测定环境空气中恶臭硫化物成分   总被引:2,自引:0,他引:2  
摘要:采用苏玛罐采样、冷阱顶浓缩处理样品、气相色谱质谱联用法测定环境空气中的甲硫醇、乙硫醇、甲硫醚、乙硫醚、甲乙硫醚、二甲二硫、二硫化碳等7种恶臭硫化物。结果表明,该方法的线性较好,7种硫化物的检出限为8.0×10-4~1.4×10-3mg/m3,混合标准气体平行测定时RSD范围在3.32%~6.17%,加标回收率为100%~117%。该方法对于环境空气恶臭硫化物的测定准确可靠,能够用于常规环境空气中恶臭硫化物的分析检测。  相似文献   

7.
以活性炭吸附大气中的吡啶,用二硫化碳解析、毛细管柱分离、FID检测器分析,采用保留时间定性、峰面积外标曲线法定量。方法在0~367mg/L范围内线性关系良好,当采样体积为20L时,最低检出质量浓度为0.007mg/m3,标准溶液平行测定的RSD≤2.0%,加标回收率为97.9%~104%。  相似文献   

8.
Motor vehicles constitute a significant source of polycyclic aromatic hydrocarbon (PAH) emissions to the atmosphere. Particle-phase priority pollutant PAH concentrations and total suspended particle mass (TSP) were measured in the Lapa bus station and the Americo Simas Tunnel, located in the city of Salvador, Brazil. Separate samples were collected at the bus station at different times of the day, including rush- and non-rush-hour periods. The highest concentrations for nearly all 16 priority PAHs measured at the bus station were observed at 18:30 h, with chrysene showing the highest mean value (26.6 ng m-3). The highest average PAH concentrations measured in the tunnel were observed for pyrene (79.4 +/- 11.5 ng m-3) followed by fluoranthene (39.0 +/- 5.2 ng m-3) and chrysene (28.0 +/- 4.17 ng m-3). TSP levels reached 423 micrograms m-3 in the bus station, and values as high as 2 mg m-3 in the tunnel. The measured Salvador tunnel PAH profiles are very similar to the Salvador bus station profiles, and are similar to PAH profiles reported for the Kojouike Tunnel, located in Kurashiki City, Japan, and the Caldecott Tunnel, located in Berkeley, California.  相似文献   

9.
A diffusive sampler for NO2, Willems badge, was validated in laboratory experiments and field tests. The collecting reagent for NO2 in the sampler is triethanolamine, and the analysis is based on a modified colorimetric method, the Saltzman method. The analysis was performed by a flow injection analysis (FIA) technique. The sampling rate for the sampler was determined to be 40.0 ml min-1. There was no effect of NO2 concentration or relative humidity on sampling rate, and the influence of sampling time was found to be small. The detection limit was 4 micrograms m-3 for a 24 h sample. The capacity is high enough to allow sampling of 150 micrograms m-3 for 7 days, which is twice the recommended Swedish short-term (24 h) guideline value as a 98-percentile over 6 months. In field tests, the sampler performed well, even at wind speeds higher than 2 m s-1, and at low temperatures. The overall uncertainty of the method was 24%. The sensitivity and capacity of the method also make it suitable for personal sampling for 2-8 h in working environments.  相似文献   

10.
OBJECTIVES: The aim of this investigation was to use activated carbon cloth (ACC) patches to study the probability and extent of dermal exposure to benzene and toluene in a shoe factory. METHODS: Inhalation and dermal exposure loading were measured simultaneously in 70 subjects on multiple days resulting in 113 observations. Dermal exposure loading was assessed by ACC patches attached to likely exposed skin areas (e.g. the palm of the hand and abdomen). A control patch at the chest and an organic vapor monitor (OVM) were used to adjust the hand and abdomen patches for the contribution from the air through passive absorption of benzene and toluene on the ACC patches. Systemic exposure was assessed by quantification of unmetabolized benzene (UBz) and toluene (UTol) in urine. RESULTS: Mean air concentrations for the study population were 1.5 and 7.5 ppm for benzene and toluene, respectively. Iterative regression analyses between the control patch, OVM and the dermal patches showed that only a small proportion of the ACC patches at the hand had likely benzene (n = 4; mean 133 microg cm(-2) h(-1)) or toluene (n = 5; mean 256 microg cm(-2) h(-1)) contamination. Positive patches were exclusively observed among subjects performing the task of gluing. Significant dermal exposure loading to the abdomen was detected only for toluene (n = 2; mean 235 microg cm(-2) h(-1)). No relation was found between having a positive hand or abdomen ACC patch and UBz or UTol levels. In contrast a strong association was found between air levels of benzene (p = 0.0016) and toluene (p < 0.0001) and their respective urinary levels. CONCLUSIONS: ACC patches are shown to be a useful technique for quantifying the probability of dermal exposure to organic solvents and to provide estimates of the potential contribution of the dermal pathway to systemic exposure. Using ACC patches we show that dermal exposure to benzene and toluene in a shoe manufacturing factory is probably rare, and when it occurred exposures were relatively low and did not significantly contribute to systemic exposure.  相似文献   

11.
Manual and automatic welding machines (which use leaded alloys) are considered to be important sources of the emission of lead fumes into the general air of the working environment. Three workplaces at a television factory were selected for the present study, to determine the control class of the working unit. The concentrations of conventional measurements ("A" sampling points) were lower than the administrative control level (statutory standard of lead, 150 microg m(-3)), whereas the maximum concentration of 264.1 microg m(-3) ("B" sampling point) was higher at one working unit than the administrative control level. However, the control classes varied between class III (bad) and class I (good).  相似文献   

12.
A procedure for the determination of atmospheric acrylic acid in air at the microgram m-3 to mg m-3 level is described. Diffusion-based sampling, designed to discriminate gaseous analytes from their particulate counterparts, has been used. Acrylic acid is collected with an efficiency of > 98% in tubular denuders coated with sodium hydroxide-barium hydroxide-hydroquinone monomethyl ether, and analyzed by high performance liquid chromatography with UV absorbance detection. The detection limit is 2.9 micrograms m-3 at a flow rate of 0.5 L min-1 and 30 min sampling time. A precision (p = 0.95, n = 10) of 7.5% of the overall procedure was achieved at the 100 micrograms m-3 level. Results of laboratory studies concerning the effect of the coating reagent and the relative humidity on the sampling efficiency as well as possible interferences, in particular by ozone, and the elimination of these interferences are discussed. This method was developed to monitor workplace atmospheres as well as ambient air in industrial environments.  相似文献   

13.
Toxic effect caused on microflora of soil by pesticide picloram application   总被引:1,自引:0,他引:1  
The toxic effect of the herbicide picloram on the microbial population of a typical Brazilian red Latosol soil was studied in a series of microcalorimetric experiments. The activity of the soil was stimulated by the addition of 6.0 mg of glucose and 6.0 mg of ammonium sulfate, under 34.8% controlled moisture, to a 1.50 mg soil sample, at 298.15 +/- 0.02 K. The net thermal effect due to the addition of the picloram to the soil was determined by interpreting the power-time curves, which were recorded on the microcalorimeter. The total thermal effect evolved by the microorganisms was affected by the increasing doses of herbicide, and varied from 0 to 10.00 micrograms g-1. An increase in picloram exposure caused a decrease of the original thermal effect, reaching a null value above 20.89 micrograms of herbicide per gram of soil. The decreases of the thermal effect evolved by microorganisms and the increase of the lag phase period are associated with the death of the microbial population. The effects caused by picloram application in this typical Brazilian soil resulted in a strong effect on the soil microbial communities.  相似文献   

14.
The dermal exposure to the suspected allergenic monoterpenes [small alpha]-pinene, [small beta]-pinene and [capital Delta](3)-carene was assessed with a patch sampling technique. The patch used was made of activated charcoal sandwiched between two layers of cotton cloth. Patches were fastened at 12 different spots on a sampling overall and at the front of a cap to estimate the potential exposure of the body. Fastening two patches on a cotton glove, one patch representing the dorsal side and one patch representing the palm of the hand respectively, assessed the exposure on the hands. Sampling was carried out during collecting of pine and spruce boards in sawmills and during sawing of pine wood pieces in joinery shops respectively. The potential dermal exposure of the total body was 29.0-1 890 mg h(-1) with a geometric mean (GM) of 238 mg h(-1) during sawing. During collecting the GM was estimated to 100 mg h(-1) with a range of 12.2-959 mg h(-1). The hands had a mean exposure of 9.24 mg h(-1) during sawing and 3.25 mg h(-1) during collecting respectively. The good correlation between the mass of contamination on the individual body parts and the potential body exposure indicates that sampling can be performed on one body part to give a good estimation of the potential body exposure. Monoterpenes were detected at patches fastened underneath the protective clothing indicating a contamination of the skin of the worker. The patch used may overestimate the dermal exposure.  相似文献   

15.
Brominated flame retardants (BFRs) are widely used in plastics, textile coatings, electrical appliances and printed circuit boards to prohibit the development of fires. In order to investigate how exposure to BFRs is related to specific occupations, samples were obtained from Norwegian individuals working at an electronics dismantling facility, in the production of printed circuit boards, or as laboratory personnel. Nine BFRs were quantified in the plasma samples: 2,4,4'-tribromodiphenyl ether (BDE-28), 2,2',4,4'-tetrabromodiphenyl ether (BDE-47), 2,2',4,4',5-pentabromodiphenyl ether (BDE-99), 2,2',4,4',6-pentabromodiphenyl ether (BDE-100), 2,2',4,4',5,5'-hexabromodiphenyl ether (BDE-153), 2,2',4,4',5,6'-hexabromodiphenyl ether (BDE-154), 2,2',3,4,4',5',6-heptabromodiphenyl ether (BDE-183), 2,4,6-tribromophenol (TriBP) and tetrabromobisphenol A (TBBP-A). The BFRs were extracted from plasma using solid-phase extraction (SPE). The plasma lipids were decomposed by treatment with concentrated sulfuric acid directly on the SPE column, prior to the elution of the BFRs. Following diazomethane derivatization, the samples were analysed by gas chromatography-electron capture mass spectrometry. The subjects working at the electronics dismantling plant had significantly higher plasma levels of TBBP-A and BDE-153 compared to the other groups, and the heptabrominated congener BDE-183 was only detected in plasma from this group. TriBP was generally the most abundant BFR present, and the plasma concentrations were in the range 0.17-81 ng g-1 lipids. BDE-47 was the dominant BDE congener in all the individual samples and the levels were in the range 0.43-14.6 ng g-1 lipids. The total amounts of the seven BDEs were 8.8, 3.9 and 3.0 ng g-1 lipids for the group of electronics dismantlers, circuit board producers and laboratory personnel, respectively. Generally, large variations in the individual concentration levels were found within the groups, especially in the group of electronics dismantlers, where the relative standard deviations for BDE concentrations were in the range 23-164%. The levels of BFRs were not correlated to age or the level of 2,2',4,4',5,5'-hexachlorobiphenyl (CB-153). The present work indicates that the population in Norway is exposed to several BFRs, probably with food as a major source. The elevated level of higher brominated BDEs and TBBP-A in the plasma from the workers at the dismantling plant suggests an additional occupational exposure for these individuals. Thus, human exposure to BFRs seems to originate from a combination of different sources; however, further studies investigating plasma samples from a larger number of individuals are necessary for a more complete assessment of human exposure pathways to these environmental contaminants.  相似文献   

16.
Concentrations of black carbon and nitrogen dioxide have been collected concurrently using a MicrAeth AE-51 and an Aeroqual GSS NO(2) sensor. Forty five sampling events with a duration spanning between 16 and 22 hours have collected 10,800 5 min data in Birmingham (UK) from July to October 2011. The high temporal resolution database allowed identification of peak exposures and which activities contributed the most to these peaks, such as cooking and commuting. Personal exposure concentrations for non-occupationally exposed subjects ranged between 0.01 and 50 μg m(-3) for BC with average values of 1.3 ± 2.2 μg m(-3) (AM ± SD). Nitrogen dioxide exposure concentrations were in the range 相似文献   

17.
The applicability of a low resolution (8 cm-1) Fourier transform infrared (FTIR) gas analyser with an absorption path length of 3 m was evaluated for the on-line monitoring of organic solvent mixture emissions in a flexographic ink manufacturing plant. The on-line monitoring revealed that the highest variations of solvent concentrations, up to three decades, occurred in the exhaust air. The FTIR analyser with a dynamic range of four decades covers well the concentration ranges typically found in the exhaust air and in the workroom air of ink manufacturing plants. The average emission rate of solvent mixture based on a sampling period of two days was 1.8 kg h-1 consisting of mainly ethanol (70%), ethyl acetate (15%) and propan-2-ol (11%). The detection limits of the analyser for the solvent compounds ranged from 0.3 to 4.3 mg m-3 and the measurement uncertainty was less than 10% in the concentration range of 8-15,000 mg m-3. These characteristics make the apparatus appropriate for most industrial hygiene applications. An FTIR spectrophotometer, equipped with an multipoint sampling unit, facilitates rapid identification of solvent components, real-time display of concentration data relevant to workroom air and environment monitoring as well as process control. Furthermore, the on-line concentration information enabled a rapid selection of representative sampling locations. The spectrophotometer is transportable, rugged and relatively simple to calibrate even in a hostile industrial environment.  相似文献   

18.
A diffusive sampling method for the determination of gaseous acetic and formic acids, using a radial symmetry diffusive sampler, has been optimised for a 7-day exposure time in this study. Sampling rate determinations were performed on data obtained from a dynamic exposure chamber, simulating the indoor conditions of an empty, closed, room, at room temperature and minimal wind speed. Analysis has been performed by means of ion chromatography. The sampling rates for formic acid concentrations of 128 microg m(-3) and 1248 microg m(-3) were determined to be 91.2 +/- 3.9 ml min(-1) and 111.6 +/- 2.8 ml min(-1), respectively. The acetic acid sampling rate was independent of the concentration in the range 160 microg m(-3)-1564 microg m(-3), and amounted to 97.3 +/- 3.1 ml min(-1). Experimentally determined sampling rates showed deviations of 3% for acetic acid, and 3-21% for formic acid, in relation to theoretically derived values. The blank values were as low as 1.69 +/- 0.07 microg for formic acid and 1.21 +/- 0.14 microg for acetic acid, and detection limits lower than 0.5 microg m(-3) could be achieved, which is an improvement of 98-99% compared to previously validated diffusive sampling methods. This study describes the first step of an extended validation program in which the applicability of these types of samplers for the measurement of organic acids will be validated and optimised for the environmental conditions typical for museum showcases.  相似文献   

19.
Emissions of five volatile organic sulfur compounds (VOSCs), including methanethiol, carbonyl sulfide, dimethyl sulfide, carbon disulfide, and dimethyl disulfide, from a heavily polluted river, Shijing River in Guangzhou of South China, was studied. The results showed that the amounts of all VOSCs emitted from the river increased from downstream to upstream along the river with increasing magnitude of water pollution. The emission of carbonyl sulfide was the highest among the target analytes, ranging from 23.8 microg m(-2) h(-1) to 42.6 microg m(-2) h(-1) at the water surface of Shijin River. The concentration levels of VOSCs on the riverbank were lower than those at the water surface either in Shijing River or in Liuxi River. However, the contribution of dimethyl disulfide to the total VOSCs on the riverbank was higher than that at the water surface in most sampling sites, indicating that there might be a point source of dimethyl disulfide on the riverbank besides diffusion from water surface. The 24-h semi-continuous monitoring data revealed that the emissions of VOSCs at the water surface peaked at 9:00 and 21:00, which was consistent with the water quality variability in Shijin River caused by daily tidal variation.  相似文献   

20.
Exposure to various chemicals can cause adverse effects to health, such as asthma and allergies, especially in children. Data on personal exposure levels in children are scarce, thus small lightweight diffusive mini-samplers for aldehydes and volatile organic compounds (VOCs) were designed to measure the exposure level of children to these chemicals. The aim of the study was to validate and examine the applicability of these mini-samplers for measuring daily chemical exposure. The diffusive mini-samplers are 20 mm in length, 11 mm in diameter, and 1.67 g in weight. The devices are cylindrically shaped with polytetrafluoroethylene membrane filters placed at each end. To measure aldehydes and acetone, 20 mg of 2,4-dinitrophenylhydrazine was used as an absorbent. To measure VOCs, a carbon molecular sieve was used. The sampling rate for each chemical was determined by parallel sampling with active samplers in a closed exposure bag. The blank levels of the chemicals and the storage stability of the device were tested. The mini-samplers were compared to commercially available diffusive samplers. To examine the applicability of the samplers, 65 elementary school children carried them for 24 h. The sampling rates for formaldehyde, acetaldehyde, and acetone were 20.9, 22.9, and 19.7 mL min(-1), respectively. The limits of quantification (LOQ) for the 24-hour sampling by high-performance liquid chromatography/ultraviolet (HPLC/UV) analysis were 8.3, 7.6, and 8.8 μg m(-3) for formaldehyde, acetaldehyde, and acetone, respectively. The sampling rates for the 11 VOCs were determined and ranged from 3.3 mL min(-1) for styrene and 2-ethyl-1-hexanol to 11.7 mL min(-1) for benzene. The LOQ for the 24-hour sampling by gas chromatography-mass spectrometry (GC-MS) analysis ranged from 5.9-105.2 μg m(-3), 1.1-24.7 parts per billion. The storage stability after 5 days ranged from 94.8 to 118.2%. Formaldehyde, acetone, benzene, and toluene were detected above the LOQ in more than 90% of the children, and the median concentrations were 21.7, 20.9, 10.1, and 21.5 μg m(-3), respectively. This study shows that the diffusive samplers developed were suitable for children to carry and were capable of measuring the children's daily chemical exposure.  相似文献   