首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A solid‐phase microextraction (SPME) fiber coated with poly(methacrylic acid‐ethylene glycol dimethacrylate) coupled to GC with a micro electron‐capture detector was developed for the determination of four chlorphenols in water samples for the first time. A novel and simple method for the preparation of this novel SPME fiber was proposed by copolymerization of methacrylic acid and ethylene glycol dimethacrylate in an appropriate solvent using a glass capillary as a “mold”. The factors affecting the polymerization were optimized in detail. Furthermore, the extraction performance of the poly(methacrylic acid‐ethylene glycol dimethacrylate) fiber was evaluated. Moreover, experimental headspace‐SPME parameters, such as extraction temperature, extraction time, salt concentration, stirring speed, and pH, were optimized by orthogonal array experimental designs. Under the optimized conditions, the target analytes were linear in the range of 0.2–50 ng/mL, and the correlation coefficients were all greater than 0.99. RSD was less than 8.9%, and the detection limits were in the range of 0.1–10 ng/L. Four cholorphenols were detected from tap and lake water samples using the proposed method, with the recoveries of spiked natural water samples were ranged from 91.8 to 110.8, and 90.6 to 111.4% for tap and lake water samples, respectively.  相似文献   

2.
A new method based on cetylpyridinium chloride coated ferroferric oxide/silica magnetic microspheres as an efficient solid‐phase adsorbent was developed for the extraction and enrichment of ochratoxin A. The determination of ochratoxin A was obtained by high‐performance liquid chromatography with fluorescence detection. In the presence of cetylpyridinium chloride, the adsorption capacity of ferroferric oxide/silica microspheres was 5.95 mg/g for ochratoxin A. The experimental parameters were optimized, including the amounts of ferroferric oxide/silica microspheres (20 mg) and cetylpyridinium chloride (0.18 mL, 0.5 mg/mL), pH value of media (9), ultrasonic time (5 min), elution solvent and volume [2(1 + 1) mL (washed twice, 1 mL each time) 1% acetic acid acetonitrile]. Under optimal experiment conditions, ochratoxin A had good linearity in the range of 2.5–250.0 ng/L in water samples with correlation coefficient of the calibration curve 0.9995. The limit of detection for ochratoxin A was 0.83 ng/L, and the recoveries were 89.8–96.8% with the relative standard deviation of 1.5–3.5% in environmental water samples. Furthermore, ferroferric oxide/silica microspheres show excellent reusability during extraction procedures for no less than six times.  相似文献   

3.
In this work, two disperser‐free microextraction methods, namely, air‐agitated liquid–liquid microextraction and ultrasound‐assisted emulsification microextraction are compared for the determination of a number of polycyclic aromatic hydrocarbons in aqueous samples, followed by gas chromatography with flame ionization detection. The effects of various experimental parameters upon the extraction efficiencies of both methods are investigated. Under the optimal conditions, the enrichment factors and limits of detection were found to be in the ranges of 327–773 and 0.015–0.05 ng/mL for air‐agitated liquid–liquid microextraction and 406–670 and 0.015–0.05 ng/mL for ultrasound‐assisted emulsification microextraction, respectively. The linear dynamic ranges and extraction recoveries were obtained to be in the range of 0.05–120 ng/mL (R2 ≥ 0.995) and 33–77% for air‐agitated liquid–liquid microextraction and 0.05–110 ng/mL (R2 ≥ 0.994) and 41–67% for ultrasound‐assisted emulsification microextraction, respectively. To investigate this common view among some people that smoking hookah is healthy due to the passage of smoke through the hookah water, samples of both the hookah water and hookah smoke were analyzed.  相似文献   

4.
A fast, sensitive, and centrifugeless ultrasound‐assisted emulsification microextraction followed by a high‐performance liquid chromatography method is developed for the determination of some phthalate esters in aqueous samples. In this method, a simple approach is followed to eliminate the centrifugation step in dispersive liquid–liquid microextraction using an organic solvent whose melting point is near the ambient temperature, consumption of the extracting solvent is efficiently reduced, and the overall extraction time was found to be only 7 min. The variables affecting the method are optimized. Under the optimal experimental conditions (75 μL of 1‐undecanol, a flow rate of 2.0 mL/min, and an ultrasound irradiation of 1 min), the proposed method exhibits good preconcentration factors (52–97), low limits of detection (1.0–5.0 ng/mL), and linearities in the range of 5–1500 ng/mL (r 2 ≥ 0.995). Finally, the method is successfully applied to the analysis of phthalate esters in the drinking and river water samples. To study the probable release of the phthalate esters from a polyethylene container into boiling water, the boiling water exposed to the polyethylene container was analyzed by the proposed method.  相似文献   

5.
An ultrasound‐assisted magnetic SPE procedure with an Fe3O4‐grafted graphene nanocomposite as the magnetic adsorbent has been developed to determine seven polychlorinated biphenyls (PCBs; PCB28, PCB52, PCB101, PCB118, PCB138, PCB153, and PCB180) simultaneously in 200 mL environmental water samples, in combination with GC–MS/MS. Several factors related to magnetic SPE efficiencies, such as the superparamagnetic intensity and amount of adsorbent, extraction time, sample pH, and desorption conditions were investigated. With the assistance of ultrasound, the extraction achieved the maximum within only 20 s, attributed to the powerful adsorptive ability of the magnetic adsorbent toward the PCBs. Under the optimized conditions, an excellent linearity was observed in the range of 0.1–100 ng/L for PCB28, 0.2–100 ng/L for PCB52, and 0.5–100 ng/L for the other five PCBs with the correlation coefficients ranging from 0.9988 to 0.9996. The mean recoveries at spiked levels of 5.0 and 10.0 ng/L were 84.9–108.5%, the coefficients of variations were <6.5%. With convenient magnetic separation, the synthesized magnetic adsorbent could be recycled more than ten times. The proposed method was demonstrated to be feasible, simple, rapid, and easy to operate for the trace analysis of the PCBs in environmental water samples.  相似文献   

6.
A three‐dimensional graphene was synthesized through a hydrothermal reaction of graphene oxide with phytic acid. The microstructure and morphology of the phytic acid induced three‐dimensional graphene were investigated by nitrogen adsorption–desorption isotherms, scanning electron microscopy, and transmission electron microscopy. With a large surface area and three‐dimensional structure, the graphene was used as the solid‐phase extraction adsorbent for the extraction of phthalate esters from bottled water and sports beverage samples before high‐performance liquid chromatographic analysis. The results indicated that the graphene was efficient for the solid‐phase extraction of phthalate esters. The limits of detection (S/N = 3) of the method for the analytes were 0.02–0.03 ng/mL for the water samples and 0.03–0.15 ng/mL for the sports beverage sample. The limits of quantitation (S/N = 9) for the analytes were 0.06–0.09 ng/mL for water samples and 0.09–0.45 ng/mL for sports beverage sample. The calibration curves for the phthalate esters by the method had a good linearity from 0.1 to 80.0 ng/mL with correlation coefficients larger than 0.9997. The recoveries of the analytes for the method fell in the range of 86.7–116.2% with the relative standard deviations between 1.5 and 6.8%.  相似文献   

7.
A simple and economical method for the determination of eight polybrominated diphenyl ethers (BDE‐28, 47, 99, 100,153,154,183, and 209) in water was developed. This method involves the use of ultrasound‐assisted dispersive liquid–liquid microextraction combined with GC‐MS in negative chemical ionization mode. Various parameters affecting the extraction efficiency, including the type and volume of extraction and dispersive solvents, salt concentration, extraction time, and ultrasonic time, were investigated. A volume of 1.0 mL of acetone (dispersive solvent) containing 10 μL tetrachloroethylene (extraction solvent) was injected into 5.0 mL of water samples and then emulsified by ultrasound for 2.0 min to produce the cloudy solution. Under the optimal condition, the enrichment factors for the eight PBDEs were varied from 845‐ to 1050‐folds. Good linearity was observed in the range of 1.0–200 ng L?1 for BDE‐28, 47, 99, and 100; 5.0–200 ng L?1 for BDE‐153, 154, and 183; and 5.0–500 ng L?1 for BDE‐209. The RSD values were in the range of 2.5–8.4% (n = 5) and the LODs ranged from 0.40 to 2.15 ng L?1 (S/N = 3). The developed method was applied for the determination of eight BPDEs in the river and lake water samples, and the mean recoveries at spiking levels of 5.0 and 50.0 ng L?1 were in the range of 70.6–105.1%.  相似文献   

8.
A headspace solid‐phase microextraction method was developed for the preconcentration and extraction of methyl tert‐butyl ether. An ionic‐liquid‐mediated multiwalled carbon nanotube–poly(dimethylsiloxane) hybrid coating, which was prepared by covalent functionalization of multiwalled carbon nanotubes with hydroxyl‐terminated poly(dimethylsiloxane) using the sol–gel technique, was used as solid‐phase microextraction adsorbent. This innovative fiber exhibited a highly porous surface structure, high thermal stability (at least 320°C) and long lifespan (over 210 uses). Potential factors affecting the extraction efficiency were optimized. Under the optimum conditions, the method LOD (S/N = 3) was 0.007 ng/mL and the LOQ (S/N = 10) was 0.03 ng/mL. The calibration curve was linear in the range of 0.03–200 ng/mL. The RSDs for one fiber (repeatability, n = 5) at three different concentrations (0.05, 1, and 150 ng/mL) were 5.1, 4.2, and 4.6% and for the fibers obtained from different batches (reproducibility, n = 3) were 6.5, 5.9, and 6.3%, respectively. The developed method was successfully applied to the determination of methyl tert‐butyl ether in different real water samples on three consecutive days. The relative recoveries for the spiked samples with 0.05, 1, and 150 ng/mL were between 94–104%.  相似文献   

9.
A new approach based on the ultrasound‐assisted reversed‐phase dispersive liquid–liquid microextraction technique is developed for the extraction and determination of vitamin A and vitamin E from oil matrices before high‐performance liquid chromatography analysis. A methodology based on the full factorial design is carried out to choose the significant parameters. Then the significant factors affecting the extraction efficiency including pH, volume of extraction solvent, and volume of disperser solvent are optimized using a Box–Behnken design. After analyzing the results obtained, the optimum conditions were: pH 4.5, 80–20 μL of the ethanol/water solvent mixture as extraction solvent, 110 μL of 1,4‐dioxane as the disperser solvent, and a sonication time of 10 min. For validation of the developed method, the linear dynamic range, repeatability, limit of detection, and recoveries were obtained under the optimum conditions. The detection limits of the method were 1.6 and 2.3 ng/mL for vitamin A and vitamin E, respectively. The extraction recovery percentages for the studied drugs were above 91%, with acceptable relative standard deviation. The proposed methodology was successfully applied for the determination of the vitamins in different oil samples.  相似文献   

10.
A simple, rapid, and sensitive method for the determination of naproxen and ibuprofen in complex biological and water matrices (cow milk, human urine, river, and well water samples) has been developed using ultrasound‐assisted magnetic dispersive solid‐phase microextraction. Magnetic ethylendiamine‐functionalized graphene oxide nanocomposite was synthesized and used as a novel adsorbent for the microextraction process and showed great adsorptive ability toward these analytes. Different parameters affecting the microextraction were optimized with the aid of the experimental design approach. A Plackett–Burman screening design was used to study the main variables affecting the microextraction process, and the Box–Behnken optimization design was used to optimize the previously selected variables for extraction of naproxen and ibuprofen. The optimized technique provides good repeatability (relative standard deviations of the intraday precision 3.1 and 3.3, interday precision of 5.6 and 6.1%), linearity (0.1–500 and 0.3–650 ng/mL), low limits of detection (0.03 and 0.1 ng/mL), and a high enrichment factor (168 and 146) for naproxen and ibuprofen, respectively. The proposed method can be successfully applied in routine analysis for determination of naproxen and ibuprofen in cow milk, human urine, and real water samples.  相似文献   

11.
A novel electrospun composite nanofiber‐based adsorbent (polyurethane/polystyrene‐silica) was fabricated, characterized, and used in the headspace solid‐phase microextraction of the acetylated derivatives of chlorophenols in water samples before gas chromatography with micro electron capture detection. The surface morphology, chemical composition, thermal stability, and structure of the fibers were investigated by scanning electron microscopy, Fourier transform infrared spectroscopy, thermogravimetric analysis, and Brunauer–Emmett–Teller and Barrett–Joyner–Halenda techniques. The effect of the main parameters influencing the efficiency of the method including extraction temperature, salt concentration, and extraction time was investigated and the optimized conditions were obtained. The linear dynamic ranges were 0.1–800 ng/mL. The relative standard deviations (n = 3) and the limits of detection were 2.64–9.57% and 0.0234–0.830 ng/mL, respectively. The relative recoveries for real samples (river water and sewage of our university campus) were between 90.8 and 111%.  相似文献   

12.
We developed a CE and ultrasound‐assisted temperature‐controlled ionic liquid emulsification microextraction method for the determination of four parabens (methyl paraben, ethyl paraben, propyl paraben, and butyl paraben) in personal care products including mouthwash and toning lotion. In the proposed extraction procedure, ionic liquid (IL, 1‐octyl‐3‐methylimidazolium hexafluorophosphate) was used as extraction solvent, moreover, no disperser solvent was needed. Parameters affecting the extraction efficiency including volume of IL, heating temperature, ultrasonic time, extraction time, sample pH, ionic strength, and centrifugation time were optimized. Under the optimized conditions, the method was found to be linear over the range of 3–500 ng/mL with coefficient of determination (R2) in the range of 0.9990–0.9998. The LODs and LOQs for the four parabens were 0.45–0.72 ng/mL and 1.50–2.40 ng/mL, respectively. Intraday and interday precisions (RSDs, n = 5) were in the range of 5.4–6.8% and 7.0–8.7%, respectively. The recoveries of parabens at different spiked levels ranged from 71.9 to 119.2% with RSDs less than 9.5%.  相似文献   

13.
For the first time, the high‐density solvent‐based solvent de‐emulsification dispersive liquid–liquid microextraction (HSD‐DLLME) was developed for the fast, simple, and efficient determination of chlorophenols in water samples followed by field‐enhanced sample injection with reverse migrating micelles in CE. The extraction of chlorophenols in the aqueous sample solution was performed in the presence of extraction solvent (chloroform) and dispersive solvent (acetone). A de‐emulsification solvent (ACN) was then injected into the aqueous solution to break up the emulsion, the obtained emulsion cleared into two phases quickly. The lower layer (chloroform) was collected and analyzed by field‐enhanced sample injection with reverse migrating micelles in CE. Several important parameters influencing the extraction efficiency of HSD‐DLLME such as the type and volume of extraction solvent, disperser solvent and de‐emulsification solvent, sample pH, extraction time as well as salting‐out effects were optimized. Under the optimized conditions, the proposed method provided a good linearity in the range of 0.02–4 μg/mL, low LODs (4 ng/mL), and good repeatability of the extractions (RSDs below 9.3%, n = 5). And enrichment factors for three phenols were 684, 797, and 233, respectively. This method was then utilized to analyze two real environmental samples from wastewater and tap water and obtained satisfactory results. The obtained results indicated that the developed method is an excellent alternative for the routine analysis in the environmental field.  相似文献   

14.
A novel and reliable method for determination of five triazole fungicide residues (triadimenol, tebuconazole, diniconazole, flutriafol, and hexaconazol) in traditional Chinese medicine samples was developed using dispersive solid‐phase extraction combined with ultrasound‐assisted dispersive liquid–liquid microextraction before ultra‐high performance liquid chromatography with tandem mass spectrometry. The clean up of the extract was conducted using dispersive solid‐phase extraction by directly adding sorbents into the extraction solution, followed by shaking and centrifugation. After that, a mixture of 400 μL trichloromethane (extraction solvent) and 0.5 mL of the above supernatant was injected rapidly into water for the dispersive liquid–liquid microextraction procedure. The factors affecting the extraction efficiency were optimized. Under the optimum conditions, the calibration curves showed good linearity in the range of 2.0–400 (tebuconazole, diniconazole, and hexaconazole) and 4.0–800 ng/g (triadimenol and flutriafol) with the regression coefficients higher than 0.9958. The limit of detection and limit of quantification for the present method were 0.5–1.1 and 1.8–4.0 ng/g, respectively. The recoveries of the target analytes ranged from 80.2 to 103.2%. The proposed method has been successfully applied to the analysis of five triazole fungicides in traditional Chinese medicine samples, and satisfactory results were obtained.  相似文献   

15.
An optimized method for the determination of five synthetic polycyclic: celestolide (ADBI), phantolide (AHMI), traseolide (ATII), galaxolide (HHCB), tonalide (AHTN), and two nitro‐aromatic musks: musk xylene (MX) and musk ketone (MK), in water samples is described. The method involves a dispersive micro solid‐phase extraction (D‐μ‐SPE) plus ultrasound‐assisted solvent desorption (UASD) prior to their determination by gas chromatography‐mass spectrometry (GC‐MS) using the selected ion storage (SIS) mode. Factors affecting the extraction efficiency of the target analytes from water samples and ultrasound‐assisted solvent desorption were optimized by a Box‐Behnken design method. The optimal extraction conditions involved immersing 10.1 mg of a typical octadecyl (C18) bonded silica adsorbent (i.e., ENVI‐18) in a 50 mL water sample. After 10.4 min of extraction by vigorously shaking, the adsorbent was collected and dried on a filter, and the target musks were desorbed by ultrasound‐assisted for 38 sec with n‐hexane (200 μL) as the desorption solvent. A 10 μL aliquot was then directly determined by large‐volume injection GC‐MS. The limits of quantitation (LOQs) were 1.2 to 5 ng/L. The precision for these analytes, as indicated by relative standard deviations (RSDs), were less than 11% for both intra‐ and inter‐day analysis. Accuracy, expressed as the mean extraction recovery, was between 74% and 92%. A preliminary analysis of the effluents from municipal wastewater treatment plants (MWTP) and river water samples revealed that HHCB and AHTN were the two most commonly detected synthetic musks; their concentration were determined to range from 88 to 690 ng/L for effluent samples, and 5 to 320 ng/L for river water samples. This is a simple, low cost, effective, and eco‐friendly analytical method.  相似文献   

16.
Using bamboo‐activated charcoal as SPE adsorbent, a novel SPE method was developed for the sensitive determination of tetrabromobisphenol A and bisphenol A in environmental water samples by rapid‐resolution LC‐ESI‐MS/MS. Important parameters influencing extraction efficiency, including type of eluent, eluent volume, sample pH, volume and flow rate, were investigated and optimized. Under the optimal extraction conditions (eluent: 8 mL methanol, pH: 7; flow rate: 4 mL/min; sample volume: 100 mL), low LODs (0.01–0.02 ng/mL), good repeatability (6.2–8.3%) and wide linearity range (0.10–10 ng/mL) were obtained. Satisfied results were achieved when the proposed method was applied to determine the two target compounds in real‐world environmental water samples with spiked recoveries over the range of 80.5–119.8%. All these facts indicate that trace determination of tetrabromobisphenol A and bisphenol A in real‐world environmental water samples can be realized by bamboo‐activated charcoal SPE‐rapid resolution‐LC‐ESI‐MS/MS.  相似文献   

17.
The simultaneous determination of amphetamine and methadone was carried out by magnetic graphene oxide nanoparticles, a magnetic solid‐phase extraction adsorbent, as a new sample treatment technique. The main factors (the amounts of sample volume, amount of adsorbent, type and amount of extraction organic solvent, time of extraction and desorption, pH, the ionic strength of extraction medium, and agitation rate) influencing the extraction efficiency were investigated and optimized. Under the optimized conditions, good linearity was observed in the range of 100–1500 ng/mL for amphetamine and 100–1000 ng/mL for methadone. The method was evaluated for determination of AM and methadone in positive urine samples, satisfactory results were obtained, therefore magnetic solid‐phase extraction can be applied as a novel method for the determination of drugs of abuse in forensic laboratories.  相似文献   

18.
In this study, a mixed hemimicelle solid‐phase extraction method based on Fe3O4 nanoparticles coated with sodium dodecyl sulfate was applied for the preconcentration and fast isolation of six fluoroquinolones in environmental water samples before high‐performance liquid chromatography determination. The main factors affecting the extraction efficiency of the analytes, such as amount of surfactant, amount of Fe3O4 nanoparticles, extraction time, sample volume, sample pH, ionic strength, and desorption conditions, were investigated and optimized. The method has detection limits from 0.05 to 0.1 ng/mL and good linearity (r ≥ 09948) in the range 0.1–200 ng/mL depending on the fluoroquinolone. The enrichment factor is ~200. The recoveries (at spiked levels of 1, 5, and 50 ng/mL) are in the range of 79–120%.  相似文献   

19.
Graphene is a novel and interesting carbon material that could be used for the separation and purification of some chemical compounds. In this investigation, graphene was used as a novel fiber‐coating material for the solid‐phase microextraction (SPME) of four triazine herbicides (atrazine, prometon, ametryn and prometryn) in water samples. The main parameters that affect the extraction and desorption efficiencies, such as the extraction time, stirring rate, salt addition, desorption solvent and desorption time, were investigated and optimized. The optimized SPME by graphene‐coated fiber coupled with high‐performance liquid chromatography‐diode array detection (HPLC‐DAD) was successfully applied for the determination of the four triazine herbicides in water samples. The linearity of the method was in the range from 0.5 to 200 ng/mL, with the correlation coefficients (r) ranging from 0.9989 to 0.9998. The limits of detection of the method were 0.05‐0.2 ng/mL. The relative standard deviations varied from 3.5 to 4.9% (n=5). The recoveries of the triazine herbicides from water samples at spiking levels of 20.0 and 50.0 ng/mL were in the range between 86.0 and 94.6%. Compared with two commercial fibers (CW/TPR, 50 μm; PDMS/DVB, 60 μm), the graphene‐coated fiber showed higher extraction efficiency.  相似文献   

20.
A sensitive technique to determinate naproxen in hair samples was developed using hollow‐fiber micro‐solid‐phase combined with fluorescence spectrophotometry. The incorporation of multi‐walled carbon nanotubes modified with a Keggin polyoxometalate into a silica matrix prepared by the sol–gel method was reported. In this research, the Keggin carbon nanotubes /silica composite was used in the pores and lumen of a hollow fiber as the hollow‐fiber micro‐solid‐phase extraction device. The device was used for the microextraction of the analyte from hair and water samples under the optimized conditions. An orthogonal array experimental design with an OA24 (46) matrix was employed to optimize the conditions. The effect of six factors influencing the extraction efficiency was investigated: pH, salt, volume of donor and desorption phase, extraction and desorption time. The effect of each factor was estimated using individual contributions as response functions in the screening process. Analysis of variance was employed for estimating the main significant factors and their contributions in the extraction. Calibration curve plot displayed linearity over a range of 0.2–10 ng/mL with detection limits of 0.072 and 0.08 ng/mL for hair and aqueous samples, respectively. The relative recoveries in the hair and aqueous matrices ranged from 103–95%. The relative standard deviation for fiber‐to‐fiber repeatability was 3.9%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号