首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 359 毫秒
1.
尚志杰 《中国科学美容》2011,(22):116-116,120
目的比较0.75%罗哌卡因和0.75%左布比卡因对剖宫产手术腰麻的临床效果。方法 160例ASA1~2级择期剖宫产手术患者随机分为0.75%罗哌卡因(R)组和0.75%左布比卡因(L)组。采用25G腰麻穿刺针,于L3~4间隙穿刺。监测两组感觉运动阻滞情况、麻醉效果及不良反应情况。结果 R组最大阻滞时间、最大运动阻滞时间均高于L组;而运动恢复时间,R组低于L组,两组比较差异有统计学意义(P〈0.05)。结论等剂量罗哌卡因和左旋布比卡因腰麻麻醉效果和不良反应差异无统计学意义,左旋布比卡因运动神经阻滞比罗哌卡因更完全,罗哌卡因则具有运动神经阻滞起效慢而恢复较快的特点。  相似文献   

2.
左旋布比卡因腰麻在剖宫产手术的应用   总被引:19,自引:1,他引:18  
目的比较0.5%重比重左旋布比卡因与0.5%重比重布比卡因腰麻用于剖宫产手术的麻醉效果.方法选择ASA Ⅰ~Ⅱ级患者60例于腰麻下行择期剖宫产手术,随机、双盲均分为两组:L组用药0.5%重比重左旋布比卡因2.4 ml(12 mg),B组用药0.5%重比重布比卡因2.4 ml(12 mg).术中连续监测呼吸和循环状况,评估麻醉效应和维持时间,并观察围手术期不良反应的发生及新生儿情况.结果两组胸椎最高阻滞平面、术中运动神经阻滞级别、T11痛觉阻滞消失时间、腰麻的运动和感觉神经阻滞作用的消退时间比较均无显著性差异;两组腹腔牵拉反应时VAS评分比较无显著性差异(P>0.05);低血压发生率L组为20%,B组为23.3%;患者满意率L组为85%,B组为87%.新生儿Apgar 1分、5分的评分两组比较无显著性差异(P>0.05).结论与0.5%重比重布比卡因的比较,0.5%重比重左旋布比卡因腰麻用于剖宫产手术同样安全有效.  相似文献   

3.
目的比较0.75%罗哌卡因与0.75%布比卡因腰麻硬膜外联合麻醉用于剖宫产手术的可行性.方法ASAⅠ~Ⅱ级初产妇40例于腰硬联合麻醉下行剖宫产手术,随机、双盲分两组R组(n=20)腰麻用药为0.75%罗哌卡因1.2~1.4ml(9~10.5mg);B组(n=20)腰麻用药为0.75%布比卡因,剂量同R组.术中两组麻醉效应不足时经硬膜外导管补充1.6%利多卡因.术中连续监测呼吸和循环状况,评估麻醉效应,并观察围术期不良反应的发生及新生儿情况.结果两组最高阻滞平面及达到时间相似(P>0.05),但R组感觉和运动神经阻滞起效慢,维持时间短(P<0.05);下肢运动阻滞程度R组显著低于B组(P<0.01);术中R组有4例(20%)发生心动过缓,B组5例(25%)出现主观气促感;新生儿Apgar评分及脐动脉血气值在正常范围内,两组比较无差异(P>0.05).结论0.75%罗哌卡因用于硬腰联合麻醉剖腹产手术安全有效,与0.75%布比卡因相比,下肢运动阻滞弱且恢复迅速.  相似文献   

4.
目的比较0.75%罗哌卡因与0.75%布比卡因腰麻硬膜外联合麻醉用于剖宫产手术的可行性.方法ASA Ⅰ~Ⅱ级初产妇40例于腰硬联合麻醉下行剖宫产手术,随机、双盲分两组:R组(n=20)腰麻用药为0.75%罗哌卡因1.2~1.4ml(9~10.5mg);B组(n=20)腰麻用药为0.75%布比卡因,剂量同R组.术中两组麻醉效应不足时经硬膜外导管补充1.6%利多卡因.术中连续监测呼吸和循环状况,评估麻醉效应,并观察围术期不良反应的发生及新生儿情况.结果两组最高阻滞平面及达到时间相似(P>0.05),但R组感觉和运动神经阻滞起效慢,维持时间短(P<0.05);下肢运动阻滞程度R组显著低于B组(P<0.01);术中R组有4例(20%)发生心动过缓,B组5例(25%)出现主观气促感;新生儿Apgar评分及脐动脉血气值在正常范围内,两组比较无差异(P>0.05).结论0.75%罗哌卡因用于硬腰联合麻醉剖腹产手术安全有效,与0.75%布比卡因相比,下肢运动阻滞弱且恢复迅速.  相似文献   

5.
目的 探讨超小剂量布比卡因复合芬太尼腰麻用于肛肠疾病患者日间手术的可行性.方法 ASAⅠ~Ⅱ级肛肠手术患者60例,随机分成两组,分别采用0.75%布比卡因0.4ml+芬太尼15μg+50%葡萄糖0.05ml行腰麻(腰麻组)和传统骶管阻滞组1.2%利多卡因25~30ml(骶麻组).记录两组患者围术期血流动力学变化,和麻醉后患者感觉阻滞起效和持续时间,最大下肢运动阻滞强度,肛门松弛度,调查外科医师和患者满意度.手术后恶心、呕吐、尿潴留、瘙痒、头痛等不良反应.结果 腰麻组痛觉阻滞起效较骶麻组快.腰麻组痛觉阻滞持续时间较骶麻组长.低血压、恶心、呕吐、尿潴留发生率、肛门松弛度两组无明显差异.瘙痒发生率腰麻组高于骶麻组.医师和患者满意度腰麻组均高于骶麻组.结论 超小剂量布比卡因复合芬太尼腰麻起效快,痛觉阻滞时间长,运动阻滞少,不良反应发生率少,是肛肠疾病手术麻醉的适合方法,用于日间手术具有可行性.  相似文献   

6.
目的探讨小剂量布比卡因复合芬太尼腰麻用于痔手术的麻醉效果及其不良反应。方法 择期行痔手术患者80例,随机分为2组,每组40例。A组采用0.5%布比卡因5 mg复合芬太尼20μg腰麻,B组采用0.5%布比卡因10 mg腰麻。观察并比较2组患者麻醉效果、血流动力学变化、下肢运动阻滞恢复时间和不良反应。结果2组患者麻醉效果均满意,A组麻醉后血压下降小于B组(P<0.05),下肢运动阻滞恢复时间短于B组(P<0.05)。低血压和恶心发生率A组低于B组(P<0.05)。结论小剂量布比卡因复合芬太尼20μg腰麻应用于痔手术麻醉效果满意,无明显不良反应。  相似文献   

7.
目的研究轻比重小剂量罗比卡因连续腰麻用于高龄患者的安全性和有效性。方法择期髋关节置换手术患者60例,年龄78~93岁,ASAⅡ~Ⅳ级,随机分为两组。用Spinocath导管针于L3~4间隙穿刺蛛网膜下隙并置管。两组分别以0.1ml/s蛛网膜下隙注入0.3%罗比卡因或0.3%左旋布比卡因轻比重溶液1.0~1.2ml,术中酌情追加0.6~0.8ml维持麻醉。比较两组痛觉、运动阻滞及恢复的异同,并观察用药后的不良反应。结果两组患者均可达到完善的镇痛效果,但罗比卡因的镇痛起效时间、运动阻滞起效时间、最大阻滞时间、最大运动阻滞时间均比左旋布比卡因显著延长(P<0.05或P<0.01);麻醉持续时间、痛觉恢复时间、运动恢复时间比左旋布比卡因显著缩短(P<0.05或P<0.01);罗比卡因最大Bromage评分明显优于左旋布比卡因(P<0.01)。结论轻比重小剂量罗比卡因连续腰麻用于高龄患者髋关节置换手术是安全的,并能达到完善的镇痛效果,不良反应少。  相似文献   

8.
目的比较左旋布比卡因、罗比卡因和布比卡因用于硬膜外麻醉剖宫产术的阻滞效果、母婴安全和药物不良反应.方法采用随机双盲法,将48例择期剖宫产手术的足月单胎产妇分为三组:0.5%左旋布比卡因组(L组)17例、0.5%罗比卡因组(R组)15例和0.5%布比卡因组(B组)16例.记录硬膜外腔给药后产妇的感觉阻滞和运动阻滞的起效和持续时间、肌松满意程度、麻醉质量评价、恶心和呕吐等不良反应及术中心率、血压、脉搏血氧饱和度和新生儿1 min和5 min Apgar评分.结果产妇的一般情况、新生儿的Apgar评分组间无显著性差异;三组术中低血压及其他不良事件(恶心和呕吐)的发生率无显著性差异;各组的麻醉质量(术中的疼痛评分和肌松满意度)基本一致;感觉阻滞起效和维持时间组间无显著性差异,运动阻滞改良Bromage评分为1分的起效时间和持续时间组间有显著性差异.结论常用量0.5%左旋布比卡因、罗比卡因和布比卡因用于剖宫产手术的硬膜外麻醉时具有相似的麻醉效能和安全性.  相似文献   

9.
目的 比较左旋布比卡因和罗哌卡因用于肌间沟臂丛神经阻滞的效果及不良反应。方法 本组自2007年5月~12月对60例行上肢手术患者,ASAI~Ⅱ级,分为罗哌卡因(R)组和左旋布比卡因(L)组,每组30例,采用肌间沟法行臂丛神经阻滞,观察感觉/运动神经阻滞的起效时间及持续时间、患者对神经阻滞满意度、不良反应。结果 两组间感觉神经和运动神经阻滞起效时间的差异无显著性(P〉0.05);L组的感觉和运动神经阻滞持续时间显著长于R组(P〈0.05),神经阻滞优良率均为100%。结论 左旋布比卡因与罗哌卡因均可安全用于临床肌间沟臂丛神经阻滞,二者有相似的药效学特性,但左旋布比卡因在术后镇痛方面略优于罗哌卡因。  相似文献   

10.
三种不同局麻药腰麻最大运动阻滞效应的比较   总被引:1,自引:0,他引:1  
目的 采用序贯试验评估罗哌卡因、左旋布比卡因和布比卡因鞘内注射后达到Bromage 3级的半数有效剂量(ED50),比较三种局麻药腰麻的运动阻滞效应.方法 腰-硬联合麻醉(CSEA)下择期行妇科手术患者99例,随机分为罗哌卡因组、左旋布比卡因组和布比卡因组,分别鞘内注射0.5%等比重罗哌卡因、左旋布比卡因或布比卡因,起始剂量均为7 mg,剂量变化梯度为1mg,鞘内注药后25 min内双下肢改良Bromage达到3级为有效.结果 罗哌卡因组腰麻产生最大运动阻滞的ED50 为9.62 mg,95%可信区间(CI)为9.16~10.09 mg;左旋布比卡因组的ED50为9.55mg,95% CI为9.01~10.11 mg;布比卡因组的ED50为6.08 mg,95% CI为5.39~6.80 mg.罗哌卡因最大运动阻滞相对效价比是布比卡因的0.63倍(95% CI 0.56~O.73).结论 罗哌卡因和左旋布比卡因腰麻的运动阻滞效应明显低于布比卡因,而罗哌卡因与左旋布比卡因无明显差异.  相似文献   

11.
Background : We investigated the vasopressor hormone response following mesenteric traction (MT) with hypotension due to prostacyclin (PGI2) release in patients undergoing abdominal surgery with a combined general and epidural anesthesia. Methods : In a prospective, randomized, placebo-controlled study we administered 400 mg ibuprofen (i.v.) in 42 patients scheduled for abdominal surgery. General anesthesia was combined with epidural anesthesia (T4-L1). Before as well as 5, 15, 30, 45, and 90 min after MT we recorded plasma osmolality, hemodynamics and measured 6-keto-PGFlα (stabile metabolite of PGI2), TXB2 (stabile metabolite of thromboxane A2) active renin, and arginine vasopressin (AVP) plasma concentrations by radioimmunoassay. Catecholamine levels were assessed by high-pressure liquid chromatography (HPLC) with electrochemical detection. Results : Following MT, arterial hypotension occurred along with a substantial PGI2 release. This was completely abolished by ibuprofen administration. Although plasma levels of 6-keto-PGF (1133 (708) vs. 60 (3) ng/L, median (median absolute deviation), P=0.0001, placebo vs. ibuprofen) remained significantly elevated, blood pressure was restored within 30 min after MT in the placebo group. At the same point in time plasma concentrations of TXB2 (164 (87) vs. 58 (1) ng/L, P=0.0001), epinephrine (46 (33) vs. 14 (6) ng/L, P=0.001), AVP (41 ± (18) vs. 12 (7) ng/L, P=0.0004), and active renin (27 (12) vs. 12 (4) ng/L, P = 0.001) were significantly higher in placebo-treated patients. Conclusion : Under combined general and epidural anesthesia arterial hypotension following MT due to endogenous PGI2 release is associated with enhanced release of AVP, active renin, epinephrine and thromboxane A2, presumably contributing to hemodynamic stability within 30 min after MT.  相似文献   

12.
Background: Halothane inhibits in vitro and in vivo activity of cytochrome P-450 (CYP) 2E1. There are several fluorinated volatile anaesthetics besides halothane, and most of them are defluorinated by CYP2E1. It is unclear whether other fluorinated anaesthetics inhibit the in vivo activity of CYP2E1.
Methods: We compared the inhibitory effects of therapeutic concentrations of four inhalational anaesthetics, halothane, enflurane, isoflurane, and sevoflurane, on chlorzoxazone metabolism in rabbits receiving artificial ventilation.
Results: All four inhalational anaesthetics decreased arterial blood pressure and increased plasma chlorzoxazone concentration. However, no significant differences in the plasma chlorzoxazone concentration were found between the four anaesthetics. The estimated chlorzoxazone clearance increased after beginning inhalation with all four agents, but no significant difference in clearance was noted between agents.
Conclusions: At therapeutic concentrations, the in vivo inhibitory effect on chlorzoxazone metabolism was similar for all four inhalational anaesthetics examined, even though their chemical characteristics and extent of hepatic metabolism differ considerably.  相似文献   

13.
Don Dame 《Artificial organs》1996,20(5):613-617
Abstract: Virtually all blood pumps contain some kind of rubbing, sliding, closely moving machinery surfaces that are exposed to the blood being pumped. These valves, internal bearings, magnetic bearing position sensors, and shaft seals cause most of the problems with blood pumps. The original teaspoon pump design prevented the rubbing, sliding machinery surfaces from contacting the blood. However, the hydraulic efficiency was low because the blood was able to "slip around" the rotating impeller so that the blood itself never rotated fast enough to develop adequate pressure. An improved teaspoon blood pump has been designed and tested and has shown acceptable hydraulic performance and low hemolysis potential. The new pump uses a nonrotating "swinging" hose as the pump impeller. The fluid enters the pump through the center of the swinging hose; therefore, there can be no fluid slip between the revolving blood and the revolving impeller. The new pump uses an impeller that is comparable to a flexible garden hose. If the free end of the hose were swung around in a circle like half of a jump rope, the fluid inside the hose would rotate and develop pressure even though the hose impeller itself did not "rotate"; therefore, no rotating shaft seal or internal bearings are required.  相似文献   

14.
Abstract: A variety of protein-bound or hydrophobic substances, accumulating as a result of pathologic conditions such as exogenous or endogenous intoxications, are removed poorly by conventional detoxification methods because of low accessibility (hemodialysis), insufficient adsorption capabilities (hemosorption), low efficiency (peritoneal dialysis), or economic limitations (high-volume plasmapheresis). Combining advantages of existing methods with microspheric technology, a module-based system was designed. Major operating parameters of the latter can be modified to allow for adjustment to individual clinical situations. An extracorporeal blood circuit including a plasmafilter is combined with a secondary high-velocity plasma circuit driven by a centrifugal pump. Different microspheric adsorbers can be combined in one circuit or applied in sequence. Thus, a prolonged treatment can be tailored using specially designed selective adsorber materials. Comparing this system with existing methods (high-flux hemodialysis, molecular adsorbent recycling system), results from our in vitro studies and animal experiments demonstrate the superior efficiency of substance removal.  相似文献   

15.
Background: The duration of action of muscle relaxants is poorly correlated to the rate of decay of their plasma concentration. The plasma concentration of mivacurium may rapidly decrease below its active concentration because of the extensive hydrolysis of mivacurium. By inflating a tourniquet on one upper limb for 3 min after the administration of atracurium, mivacurium or vecuronium, we studied the influence of the initial decline of their plasma concentration on their effect. Methods: In 50 patients anaesthetised with thiopental, isoflurane and fentanyl, the effect of bolus doses of 0.15 or 0.25 mg . kg?1 mivacurium (MIV 15, MIV 25), 0.3 or 0.5 mg . kg?1 atracurium (ATR 30, ATR 50) and 0.06 or 0.1 mg . kg?1 vecuronium (VEC 06, VEC 10) were measured on both arms (evoked response of the adductor pollicis to train-of-four stimulation every 12 s), a tourniquet being applied on one arm just before and during 3 min after the muscle relaxant bolus. Results: Tourniquet inflation of 3 min almost abolished the neuromuscular effect of mivacurium. In the vecuronium groups and in the ATR 50 group, tourniquet inflation did not modify the maximum degree of depression of the twitch response. Also, the duration of action of vecuronium was unaffected by the tourniquet. In the ATR 30 group, times to return of the twitch response to 25% (duration 25%) and 75% (duration 75%) of control response were significantly shorter in the cuffed arm, 23 min vs 27 min, and 41 min vs 45 min, respectively. In the ATR 50 group, only duration 25% was significantly shorter in the cuffed arm (41 min vs 45 min). Conclusion: The results suggest that the rate of decline of the plasma concentration of mivacurium is so rapid, that a very low and almost clinically ineffective concentration is present as soon as 3 min after its administration. The results also indicate that the recovery from a mivacurium-induced neuromuscular blockade is not influenced by the rate of decay of its plasma concentration in patients with genotypically normal plasma cholinesterase.  相似文献   

16.
Abstract: Membrane processes play a pivotal and enabling role in modern replacement therapy for acute and chronic organ failure and in the management of immunologic diseases. In fact, virtually all contemporary extracorporeal blood purification methods employ membrane devices, and the next generation of artificial organs and tissue engineering therapies are almost certain to be similarly grounded in membrane technology. In this short essay, we comment on the similarities and differences among synthetic membranes and their natural counterparts and also provide a critical overview of the demographics and technology of hemodialysis, hemofiltration, apheresis, oxygenation, and emerging membrane technologies and applications.  相似文献   

17.
Background : Our objective was to determine whether administration of propranolol or verapamil modifies the hemodynamic adaptation to continuous positive-pressure ventilation (CPPV), in particular the regional distribution of cardiac output (CO).
Methods : General hemodynamics and regional blood flows assessed by microsphere technique (15 (μm) were recorded in 16 anesthetized pigs during spontaneous breathing (SB) and CPPV with 8 cm H2O end-expiratory pressure (CPPV8) before and after intravenous administration of propranolol (0.3 mg · kg−1 followed by 0.15 mg · kg−1 · h−1, n=8) or verapamil (0.1 mg · kg−1 followed by 0.3 mg · kg−1 · h−1, n=8).
Results : CPPV8 depressed CO by 25% without shifts in its relative distribution with the exception of a noteworthy increase in adrenal perfusion. Propranolol increased arterial blood pressure, and due to a fall in heart rate, CO dropped by 25%. The kidneys and, to a lesser extent, the splanchic region and central nervous system received increased fractions of the remaining CO at the expense of skeletal muscle flow. Similar patterns were seen during SB and CPPV8 such that the combination of propranolol and CPPV8 depressed CO by 50%. The circulatory effects of verapamil were less evident but myocardial perfusion tended to increase.
Conclusions : The combination of propranolol or verapamil with CPPV does not result in any specific hemodynamic interaction in anesthetized pigs, except that the combined effect of propranolol and CPPV may severely reduce CO.  相似文献   

18.
Background : Inhibitory effects of volatile anaesthetics on platelet aggregation have been demonstrated in several studies. However, the influence of volatile anaesthetics on intracoronary platelet adhesion has not been elucidated so far.
Methods : Isolated hearts of guinea pigs were perfused with buffer in the absence or presence of volatile anaesthetics (0.5 and 1 MAC) at constant coronary flow rates of 5 ml/min for 25 min, then 1 ml/min for 30 min and again 5 ml/min for 10 min. Before, during and after low-flow perfusion, a bolus of human platelets was applied into the coronary system. To simulate thrombogenic conditions, 0.3 U/ml human thrombin was infused during low-flow perfusion and reperfusion. The number of platelets sequestered to the endothelium was calculated from the difference between coronary in- and output of platelets. The myocardial production of lactate and consumption of pyruvate and coronary perfusion pressure were also determined.
Results : At a flow rate of 5 ml/min only about 3% of the applied platelets did not emerge from the coronary system, in any group. In contrast, 13.1±1.2% (mean±SEM) of infused platelets became adherent in low-flow perfusion in the control group without anaesthetic. The adherence was reduced with each 1 MAC isoflurane (to 6.2±1.2%), sevoflurane (to 4.4±0.9%) or halothane (to 3.2±1.5%) (each P <0.05 vs. control). Volatile anaesthetic, 0.5 MAC, did not inhibit platelet adhesion to a statistically significant extent in any case. Perfusion pressure and metabolic parameters were not statistically different between the control and the hearts exposed to anaesthetics.
Conclusion : Volatile anaesthetics in a concentration of 1 MAC can reduce the adhesion of platelets in the coronary system under reduced flow conditions. This action does not arise from vasodilation or inhibition of ischaemic stress.  相似文献   

19.
Background: Obesity is increasing globallly, including in the formerly "Eastern Bloc" countries. Methods: A survey was made of obesity and bariatric surgery. Results: In the 8 East and Central European countries studied, with total population 300 million, roughly 43% of the population was overweight (BMI 25-30), 23% obese (BMI > 30), with about 15 million people morbidly obese (BMI > 40). From 0-10 morbidly obese individuals/100,000/year undergo bariatric surgery. Conclusion: Most countries were found to provide inadequate treatment for obesity.The majority of the morbidly obese are not treated effectively. However, health-care awareness of obesity and bariatric surgeons are slowly increasing.  相似文献   

20.
Abstract: Numerous articles have been published on the multiple use of dialyzers and on the effect of different reprocessing chemicals and techniques on the dialyzer biocompatibility and performance. The results often appear contradictory, especially those comparing standard biocompatibility parameters. Despite this confusion, a discerning review of the published works allows certain limited conclusions to be drawn. Reprocessing of used hemodialyzers changes the biocompatibility profile of a dialyzer as defined by the parameters complement activation. leukopenia, and cytokine release. The effect of reprocessing depends on the chemicals and reprocessing technique applied and also on the type of membrane polymer being subjected to the reprocessing procedure. Reports of pyrogenic reactions indicate that the flux of the membrane also influences how suitable it is for safe reuse. An increased risk of allergic and pyrogenic reactions appears to be associated with dialyzer reuse. Furthermore, there has been a lack of investigations into the immunologic effect of the layer of adsorbed and chemically altered proteins that remains on the inner surface of reprocessed dialyzers. We conclude that the clinical benefit of dialyzer reuse cannot be generally accepted from a biocompatibility point of view.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号