首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Structural Upgrading of Masonry Columns by Using Composite Reinforcements   总被引:3,自引:0,他引:3  
Emerging techniques that use fiber-reinforced polymer (FRP) composites for strengthening and conservation of historic masonry are becoming increasingly accepted. In the last decades steel plates or wood frames were used for external confinement in containing the lateral dilation of masonry columns subjected to axial loads. In the last years FRP epoxy bonded strips or jackets were also employed to increase strength and ductility with encouraging results in terms of mechanical behavior and cost effectiveness. The behavior of masonry columns confined with FRP and subjected to axial compression is studied in this paper. An extended experimental investigation is presented in order to show the mechanical behavior of circular masonry columns built with calcareous blocks that may be commonly found in Italy and all over Europe in historical buildings. Different stacking schemes were used to build the columns, aiming to simulate the most common situations in existing masonry structures. Carbon FRP sheets were applied as external reinforcement; different amounts and different schemes of confining reinforcement were studied. The experiments include a new reinforcement technique made by using injected FRP bars through the columns cross section. Such a solution can be considered in place of a more traditional confinement, when external reinforcement must be avoided, or in addition to external reinforcement when an improved confinement effect is required. The structural behavior of masonry columns damaged under different levels of load and strengthened by using FRP reinforcements, was also investigated. Experimental results revealed the effectiveness of the FRP confinement for masonry columns, also for columns that were strongly predamaged before strengthening. A computation of the ultimate load was conducted using the Italian National Research Council recommendations to show an application of the design approach recently proposed in Italy. An existing analytical model, previously developed by the writers, was applied for computation of expected experimental values.  相似文献   

2.
In recent years, fiber-reinforced polymer (FRP) wrapping effectiveness has been clearly confirmed especially with reference to concrete structures. Despite evident advantages of FRP based confinement on members subjected to compressive overloads due to static or seismic actions, the use of such technique in the field of masonry has not been fully explored. Thus, to assess the potential of confinement of masonry columns, the present paper shows the results of an experimental program dealing with 18 square cross sections (listed faced tuff or clay brick) masonry scaled columns subjected to uniaxial compression load. In particular, three different confinement solutions have been experimentally analyzed in order to evaluate and compare the effectiveness of uniaxial glass FRP, carbon FRP, and basalt FRP laminates wrapping. The main experimental outcomes are presented and discussed in the paper considering mechanical behavior of specimens, axial stress-axial strain relationships, and effective strains at failure on the reinforcement. Test results have showed that the investigated confining systems are able to provide significant gains both in terms of compressive strength and ductility of masonry columns. Results of the presented experimental activity along with data available in the literature have been finally used to assess the reliability of the main existing analytical models; refined equations have been then proposed to minimize the scattering between theoretical predictions and experimental available data.  相似文献   

3.
Earthquake damage to unreinforced masonry buildings has shown the vulnerability of perimeter walls to out-of-plane failure. This paper describes a study that was carried out to develop and test innovative fiber reinforced polymer (FRP) rehabilitation techniques that meet the stringent requirements for strengthening historical buildings and to be cost-effective alternatives applicable to other existing masonry structures. Unobtrusive FRP rehabilitation techniques that utilize flexible carbon fiber composite cables, mounted near the surface of the fa?ade walls in epoxy-filled grooves in the bed and head joints, were developed. Ten full size walls were constructed of clay bricks and retrofitted using the developed FRP rehabilitation techniques. The test results demonstrated the high efficiency of the rehabilitation techniques under both monotonic and quasistatic cyclic loadings. Significant increases in ultimate capacities, energy absorption, and deformability were achieved for various reinforcing schemes compared to the behavior of the unreinforced walls.  相似文献   

4.
Restrained shrinkage is a major source of damage to buildings. By the combination of different construction materials, or through different conditions of exposure of different structural elements, differential dimensional change occurs. Thereby, stresses arise, which can cause cracking. In recent combined experimental and numerical research projects, this source of damage to masonry walls has been confirmed. The ability has been developed to predict the level of damage computationally. This paper addresses a method to reduce the width of cracks in masonry walls subjected to restrained shrinkage, to acceptable levels. Crack control by externally applied carbon fiber reinforced polymer (CFRP) reinforcement is studied. Although structural strengthening by CFRP reinforcement is actively researched, its application here to preserve structural serviceability is novel. An experiment was designed and performed to study the response of an unreinforced masonry wall to restrained shrinkage. Subsequently, the wall was repaired and reinforced on one face with CFRP strips. The required CFRP reinforcement was designed by finite element analysis, which also served as prediction of the response of the reinforced wall to restrained shrinkage.  相似文献   

5.
The paper aims to contribute to a better understanding of the behavior of reinforced concrete columns confined with fiber-reinforced polymer (FRP) sheets. In particular, some new insights on interaction mechanisms between internal steel reinforcement and external FRP strengthening and their influence on efficiency of FRP confinement technique are given. In this context a procedure to generate the complete stress-strain response including new analytical proposals for (1) effective confinement pressure at failure; (2) peak stress; (3) ultimate stress; (4) ultimate axial strain; and (5) axial strain corresponding to peak stress for FRP confined elements with circular and rectangular cross sections, with and without internal steel reinforcement, is presented. Interaction mechanisms between internal steel reinforcement and external FRP strengthening, shown by some experimental results obtained at the University of Padova with accurate measurements, are taken into account in the analytical model. Four experimental databases regarding FRP confined concrete columns, with circular and rectangular cross section with and without steel reinforcement, are gathered for the assessment of some of the confinement models shown in literature and the new proposed model. The proposed model shows a good performance and analytical stress-strain curves approximate some available test results quite well.  相似文献   

6.
Recent earthquakes have produced extensive damage in a large number of existing masonry buildings, demonstrating the need for retrofitting masonry structures. Externally bonded carbon fiber is a retrofitting technique that has been used to increase the strength of reinforced concrete elements. Sixteen full-scale shear dominant clay brick masonry walls, six with wire-steel shear reinforcement, were retrofitted with two configurations of externally bonded carbon fiber strips and subjected to shear loading. The results of the experimental program showed that the strength of the walls could be increased 13–84%, whereas, their displacement capacity increased 51–146%. This paper presents an analysis of the experimental results and simple equations to estimate the cracking load and the maximum shear strength of clay brick masonry walls, retrofitted with carbon fiber.  相似文献   

7.
Fiber-reinforced polymer (FRP) composites have been examined as a convenient and cost-effective means of strengthening unreinforced masonry structures. Seismic design in the United States is almost entirely based on the assumption that the structural system provides a ductile failure mode. FRP strengthened masonry walls inherently have brittle failure modes due to the nature of the strengthening system. The concept explored in this article is the introduction of ductility using a hybrid strengthening system. This involves the placement of structural steel or reinforcing steel at critical locations in the lateral force resisting system. This article presents the testing and analysis of a ductile structural steel connection that can be used to strengthen the connection of FRP strengthened shear walls to the foundation. The connection also increases energy dissipation. Results indicate that a ductile failure mode can be attained when the connection is designed to yield prior to the failure of the FRP strengthening.  相似文献   

8.
An experimental study was carried out to develop and test innovative fiber-reinforced polymer (FRP) rehabilitation techniques that meet the stringent requirements of restoration of historical buildings and are cost-effective alternatives applicable to existing masonry structures. In these techniques, FRP reinforcement was either unbonded or intermittently bonded to the masonry wall. In order to analyze performance, extend the range of the investigated parameters, and define limitations, a simplified analytical model was developed to predict the postcracking lateral load-displacement response under biaxial bending. The response of the retrofitted walls cannot be modeled by conventional approaches. The proposed model is based on balancing internal and external work and rigid body mechanics. It is assumed that all postcracking deformations take place at cracks between wall subpanels. Postcracking displacements are calculated from rotation rather than curvature. The adequacy of the model was verified by comparisons with the experimental results and a good agreement was found. The model could be used as the basis for a design method.  相似文献   

9.
A combined experimental and numerical program was conducted to study the in-plane shear behavior of clay brick masonry walls strengthened with near surface mounting carbon-fiber-reinforced polymer (CFRP) strips. This paper is focused on the numerical program. A two-dimensional finite-element (FE) model was used to simulate the behavior of FRP-strengthened wall tests. The masonry was modeled using the micromodeling approach. The FRP was attached to the masonry mesh using the shear bond-slip relationships determined from experimental pull tests. The model was designed in a way so that FRP crossing a sliding crack (perpendicularly) would prevent crack opening, normal to the direction of sliding (dilation), and increase sliding resistance. This sliding resisting mechanism was observed in the experimental tests. The FE model reproduced the key behaviors observed in the experiments, including the load-displacement response, crack development, and FRP reinforcement contribution. The FE model did not include masonry cracking adjacent to the FRP and through the wall thickness (as observed in some experiments). This type of cracking resulted in premature FRP debonding in the experiments. Debonding did not occur in the FE model because this type of masonry cracking was not modeled.  相似文献   

10.
In 2003, an experimental research program was initiated at the American University of Beirut with the objectives of (1) evaluating the effectiveness of external fiber-reinforced polymer (FRP) confinement in improving the bond strength of spliced reinforcement in reinforced-concrete (RC) columns and its implications on the lateral load capacity and ductility of the columns under seismic loading; and (2) establishing rational design criteria for bond strengthening of spliced reinforcement using external FRP jackets. This paper presents a discussion of recent experimental results dealing with rectangular columns and the results of a pilot study conducted on circular columns with particular emphasis on aspects related to the bond strength of the spliced column reinforcement. A nonlinear analysis model is developed for predicting the envelope load–drift response, taking into account the effect of FRP confinement on the stress–strain behavior of concrete in compression. Results predicted by the model showed excellent agreement with the test results. Design expressions of the bond strength of spliced bars in FRP-confined concrete were assessed against the current experimental data, and a criterion for seismic FRP strengthening of bond-critical regions in RC members is proposed.  相似文献   

11.
The behavior of seven one-half scale masonry specimens before and after retrofitting using fiber-reinforced polymer (FRP) is investigated. Four walls were built using one-half scale hollow clay masonry units and weak mortar to simulate walls built in central Europe in the mid-20th century. Three walls were first tested as unreinforced masonry walls; then, the seismically damaged specimens were retrofitted using FRPs. The fourth wall was directly upgraded after construction using FRP. Each specimen was retrofitted on the entire surface of a single side. All the specimens were tested under constant gravity load and incrementally increasing in-plane loading cycles. The tested specimens had two effective moment/shear ratio, namely, 0.5 and 0.7. The key parameter was the amount of FRP axial rigidity, which is defined as the amount of FRP reinforcement ratio times its E modulus. The single-side retrofitting/upgrading significantly improved the lateral strength, stiffness, and energy dissipation of the test specimens. The increase in the lateral strength was proportional to the amount of FRP axial rigidity. However, using high amount of FRP axial rigidity led to very brittle failure. Finally, simple existing analytical models estimated the ultimate lateral strengths of the test specimens reasonably well.  相似文献   

12.
In this paper the results of 18 pull tests performed on clay brick masonry prisms strengthened with near-surface mounted carbon fiber-reinforced polymer (CFRP) strips are presented. The pull tests were designed to add to the existing database and investigate variables significant to masonry construction. FRP was bonded to solid clay brick masonry; FRP aligned both perpendicular and parallel to the bed joint; and in the case of FRP reinforcement aligned parallel to the bed joint, compression applied perpendicular to the strip was used to simulate vertical compression load in masonry walls. Results including bond strength, critical bond length, and the local bond-slip relationship are presented as well as a discussion on the effect of the new variables on these results.  相似文献   

13.
Strengthening of Infill Masonry Walls with FRP Materials   总被引:1,自引:0,他引:1  
This paper evaluates the effectiveness of different externally bonded glass fiber–reinforced polymer (GFRP) systems for increasing the out-of-plane resistance of infill masonry walls to loading. The research included a comprehensive experimental program comprising 14 full-scale specimens, including four unstrengthened (control) specimens and 10 strengthened specimens. To simulate the boundary conditions of infill walls, all specimens consisted of a reinforced concrete (RC) frame, simulating the supporting RC elements of a building superstructure, which was infilled with solid concrete brick masonry. The specimens were loaded out-of-plane using uniformly distributed pressure to simulate the differential (suction) pressure induced by a tornado. Parameters investigated in the experimental program included aspect ratio, FRP coverage ratio, number of masonry wythes, and type of FRP anchorage. Test results indicated that the type of FRP anchorage had a significant effect on the failure mode. Research findings concluded that GFRP strengthening of infill masonry walls is effective in increasing the out-of-plane load-carrying capacity when proper anchorage of the FRP laminate is provided.  相似文献   

14.
Masonry structures have demonstrated their seismic vulnerability during recent world seismic events. This paper investigates in-plane seismic performance of unreinforced masonry (URM) walls before and after they are retrofit using fiber-reinforced polymer (FRP) materials. An assessment of available design formulas for evaluating both the in-plane performance of URM walls and the contribution of FRP strengthening systems was performed. Walls with two configurations of the FRP reinforcement have been analyzed: one based on FRP strips installed parallel to the mortar joints, the other characterized by FRP strips arranged along the diagonals of the wall. Based on shear–compression tests carried out on FRP-strengthened masonry walls available in the literature, a comparison between theoretical and experimental data is performed. A discussion about the FRP strains at failure of the walls is provided and values of effective FRP strains to be used for design purposes are proposed.  相似文献   

15.
A model to analyze the behavior of reinforced concrete tension ties strengthened with fiber reinforced plastic (FRP) laminates is developed that allows introduction of a nonlinear constitutive relationship for materials and bond-slip laws at the steel and FRP interface. Experimental results are introduced and compared with analytical results confirming the model reliability. By using the model, a numerical study is carried out to provide evidence of the influence of the amount of fibers and the tension-stiffening behavior of strengthened elements. Considering elements with the same mechanical percentage of reinforcement but composed of different amounts of steel and fibers, the stiffness is influenced only after steel yielding, even if the crack width is reduced by the external strengthening. Finally, evidence is provided for the reduction of tension stiffening in strengthened elements due to reduction of crack spacing.  相似文献   

16.
Insufficient or deteriorating reinforced-concrete piers in many existing bridges are required to be strengthened using economical, fast, and efficient methods. Currently, only a few methods can be used to strengthen circular columns. Steel jackets and fiber-reinforced polymer (FRP) composites are the two commonly used methods. In this study, along with these two strengthening methods, concrete jackets reinforced with spiral rebar, welded wire fabric (WWF), and a new steel reinforcement called PCS are investigated under different axial-load applications. Fifteen identical specimens were constructed, strengthened, and tested: one column with no strengthening; three columns strengthened with FRP; two with steel jacketing; and nine with concrete jacketing (two with WWF, three with spiral rebar, and four with the new reinforcement). The bare or unretrofitted specimens had a 152?mm (6?in.) diameter, while the outside diameter of concrete-jacketed specimens was 254?mm (10?in.). Effectiveness of each strengthening method in increasing the stiffness, axial capacity, and displacement ductility was investigated using the experimental data.  相似文献   

17.
This study concentrates on analytical evaluation of the effect of external confinement using fiber reinforced polymers (FRP) sheets on the response of concrete rectangular columns designed for gravity load only and having spliced longitudinal reinforcement at the column base. A general analytical scheme for evaluating the strength capacity and ductility of the columns under combined flexural–axial loads was developed. The analysis takes into account the bond strength degradation of the spliced reinforcement with increase in lateral load by incorporating a generalized bond stress–slip law, and considers the effect of FRP confinement on the stress–strain response of concrete material. Particular emphasis is placed in the analysis on the slip response of the spliced bars and the consequent fixed end rotation that develops at the column base. Results predicted by the analysis showed very good agreement with limited experimental data. A parametric evaluation was carried out to evaluate the effect of different design and strength parameters on the column response under lateral load. Without confinement, the columns suffered premature bond failure and, consequently, low flexural strength capacity. Confining the concrete in the columns end zone at the splice location with FRP sheets enhanced the bond strength capacity of the spliced reinforcement, increased the steel stress that can be mobilized before bond failure occurs, and consequently improved the flexural strength capacity and ductility of the columns. A general design equation, expressed as a function of the main parameters that influence the bond strength capacity between spliced steel bars and FRP confined concrete, is proposed to calculate the area of FRP sheets needed for strengthening of the subject columns.  相似文献   

18.
Currently, considerable interest exists in the use of fiber-reinforced polymer (FRP) reinforcement for concrete structures. Due to the generally lower modulus of elasticity of FRP in comparison with steel and the linear behavior of FRP, certain aspects of the structural behavior of RC members reinforced with FRP may be substantially different from similar elements reinforced with steel reinforcement. In this two-part paper the use of different types of FRP grid reinforcement for concrete slabs is investigated, presenting detailed experimental and analytical work. In the first part, the structural behavior in one-way bending is considered. This paper shows which structural measures are needed to ensure acceptable serviceability behavior. The presented analysis and discussion of test results covers the ultimate state and the ultimate limit state for bending, serviceability limit states, ductility, deformability, and ultimate to service load ratio.  相似文献   

19.
One disadvantage of most available stress–strain models for concrete confined with fiber-reinforced polymer (FRP) composites is that they do not take into consideration the interaction between the internal lateral steel reinforcement and the external FRP sheets. According to most structural concrete design codes, concrete columns must contain minimum amounts of longitudinal and transverse reinforcement. Therefore, concrete columns that have to be retrofitted (and therefore confined) with FRP sheets usually contain lateral steel. Hence, the retrofitted concrete column is under two actions of confinement: the action due to the FRP and that due to the steel ties. This paper presents a new designed-oriented confinement model for the axial and lateral behavior of circular concrete columns confined with steel ties, FRP composites, and both steel ties and FRP composites. Comparison with experimental results of confined concrete stress–strain curves shows good agreement between the test and predicted results.  相似文献   

20.
Torsional Capacity of CFRP Strengthened Reinforced Concrete Beams   总被引:1,自引:0,他引:1  
Many buildings and bridge elements are subjected to significant torsional moments that affect the design, and may require strengthening. Fiber-reinforced polymer (FRP) has shown great promise as a state-of-the-art material in flexural and shear strengthening as external reinforcement, but information on its applicability in torsional strengthening is limited. Furthermore, available design tools are sparse and unproven. This paper briefly recounts the experimental work in an overall investigation of torsional strengthening of solid and box-section reinforced concrete beams with externally bonded carbon fiber-reinforced polymer (CFRP). A database of previous experimental research available in literature was compiled and compared against fib Bulletin 14. Modifications consistent with the space truss model were proposed to correct the poor accuracy in predictions of CFRP contribution to strength. Subsequently, a design tool to analyze the full torsional capacity of strengthened reinforced concrete beams was validated against the experimental database.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号