首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A numerical and an analytical model were developed to predict the volatile organic compound (VOC) emission rate from dry building materials. Both models consider the mass diffusion process within the material and the mass convection and diffusion processes in the boundary layer. All the parameters, the mass diffusion coefficient of the material, the material/air partition coefficient, and the mass transfer coefficient of the air can be either found in the literature or calculated using known principles.

The predictions of the models were validated at two levels: with experimental results from the specially designed test and with predictions made by a CFD model. The results indicated that there was generally good agreement between the model predictions, the experimental results, and the CFD results. The analytical and numerical models then were used to investigate the impact of air velocity on emission rates from dry building materials. Results showed that the impact of air velocity on the VOC emission rate increased as the VOC diffusion coefficient of the material increased. For the material with a diffusion coefficient >10−10 m2/s, the VOC emission rate increased as the velocity increased; air velocity had significant effect on the VOC emission. For the material with a VOC diffusion coefficient <10−10 m2/s, the VOC emission rate increased as the velocity increased only in the short-term; <24 h. In the medium to long-term time range, the VOC emission rate decreased slightly as the air velocity increased; velocity did not have much impact on these materials. Furthermore, the study also found that the VOC concentration distribution within the material; the VOC emission rate and the VOC concentration in the air were linearly proportional to the initial concentration. However, the normalized emitted mass was not a function of the initial concentration: it was a function of the properties of the VOC and the material.  相似文献   


2.
《Building and Environment》2004,39(2):165-177
Sources of VOCs were identified and quantified in five tropical air-conditioned office buildings in Singapore. A mass balanced model is applied to determine area-specific emission rates and to apportion the sources of VOCs into 3 broad categories of sources—building materials, ventilation systems and occupants and their activities. The highest contributor of TVOCs comes from the ventilation systems at 39.0%. This was followed by occupants and their activities at 37.3% and finally building materials at 23.7%. Ducted supply and return ventilation design has the lowest VOC area-specific emission rates as compared to buildings employing the open space above the false ceiling as return plenum. The TVOC area-specific emission rates from building materials and ventilation systems decreased from 6 to 12 months. However, some VOCs showed increased emission rates over the same period demonstrating sink effects which resulted in secondary emissions.  相似文献   

3.
Abstract This study deals with the modeling of air pollution in apartments from laboratory measurements of source strengths, using formaldehyde and Total Volatile Organic Compounds (TVOCs) as model pollutants. The sources in two test apartments were grouped into two: building-related sources and occupant-related sources. The measured source strengths and ventilation rates were used for the prediction of concentrations expected in the apartments. These predictions were compared to measurements in the apartment over 12 months. The conclusions were that the model predictions based on emission rates measured in the laboratory can be used to predict the long-term concentration of the two model pollutants in the apartments. Considering the measured differences in ventilation between the apartments, an occupant emission rate of between 0.2 and 0.3 mg/h/kg body weight could be estimated. Based on previous suggested limits of acceptable exposures of humans to VOCs, an acceptable average emission rate of VOCs from building materials in general was estimated to be about 30 (μ/m2/h. The modeling showed that during the first 200 days, building materials dominated the emissions. After this, sources relating to the occupants dominated. On average about half of the VOC pollution originated from the building materials.  相似文献   

4.
A review of the emission of VOCs from polymeric materials used in buildings   总被引:6,自引:0,他引:6  
Building and furnishing materials and consumers products are important sources of formaldehyde and other volatile organic compounds (VOCs) in the indoor environment. The emission from materials is usually continuous and may last for many years in a building. The available evidence indicates that VOCs can cause adverse health effects to the building occupants and may contribute to symptoms of ‘Sick Building Syndrome’.

Control of VOC emission should increasingly become an important consideration for the design and manufacture of polymeric materials used in buildings. The EC Construction Products Directive ‘Essential Requirements’ set a framework for limiting the use of materials that could pose a health risk to building occupants. Furthermore, the on-going development of voluntary labelling schemes and data bases of material emissions that could be used by building designers, should further strengthen the demand for ‘low VOC emitting’ products.

This paper reviews available information about the emission of VOCs from polymeric building materials, the level of emissions in the indoor environment and the requirements for testing of the materials.  相似文献   


5.
Treatment of fresh air in ventilation systems for air-conditioning consumes a considerable amount of energy and affects the indoor air quality (IAQ). In this study, energy impact on ventilation systems was examined against certain IAQ objectives for indoor formaldehyde exposure risk in air-conditioned offices of Hong Kong. Thermal energy consumptions for ventilation systems and indoor formaldehyde exposure concentrations based on some regional surveys of typical offices in Hong Kong were reviewed. The thermal energy consumptions of ventilation systems operating for CO2 exposure concentrations between 800 ppmv and 1200 ppmv for typical office buildings and the corresponding formaldehyde exposure risks were evaluated. The results showed that, for a reference indoor environment at a CO2 exposure concentration of 1000 ppmv, the average thermal energy saving of ventilation system for a unit increment of the acceptable formaldehyde exposure limit of 1 h (loss of life expectancy of 0.0417 day) was 280 MJ m−2 yr−1; and for a unit decrement of the exposure limit of 1 h, an additional average thermal energy consumption of 480 MJ m−2 yr−1 was expected. This study would be a useful source of reference in evaluation of the energy performance of ventilation strategies in air-conditioned offices at a quantified exposure risk of formaldehyde.  相似文献   

6.
Godwin C  Batterman S 《Indoor air》2007,17(2):109-121
Indoor air quality (IAQ) parameters in 64 elementary and middle school classrooms in Michigan were examined for the purposes of assessing ventilation rates, levels of volatile organic compounds (VOCs) and bioaerosols, air quality differences within and between schools, and emission sources. In each classroom, bioaerosols, VOCs, CO(2), relative humidity, and temperature were monitored over one workweek, and a comprehensive walkthough survey was completed. Ventilation rates were derived from CO(2) and occupancy data. Ventilation was poor in many of the tested classrooms, e.g., CO(2) concentrations often exceeded 1000 ppm and sometimes 3000 ppm. Most VOCs had low concentrations (mean of individual species <4.5 microg/m(3)); bioaerosol concentrations were moderate (<6500 count per m(3) indoors, <41,000 count per m(3) outdoors). The variability of CO(2), VOC, and bioaerosol concentrations within schools exceeded the variability between schools. These findings suggest that none of the sampled rooms were contaminated and that no building-wide contamination sources were present. However, localized IAQ problems might remain in spaces where contaminant sources are concentrated and that are poorly ventilated. PRACTICAL IMPLICATIONS: Indoor air quality (IAQ) is a continuing concern for students, parents, teachers, and school staff, leading to many complaints regarding poor IAQ. Investigations of these complaints often include air sampling, which must be carefully conducted if representative data are to be collected. To better understand sampling results, investigators need to account for the variability of contaminants both within and between schools.  相似文献   

7.
Hodgson AT  Rudd AF  Beal D  Chandra S 《Indoor air》2000,10(3):178-192
Concentrations of 54 volatile organic compounds (VOCs) and ventilation rates were measured in four new manufactured houses over 2-9.5 months following installation and in seven new site-built houses 1-2 months after completion. The houses were in four projects located in hot-humid and mixed-humid climates. They were finished and operational, but unoccupied. Ventilation rates ranged from 0.14-0.78 h-1. Several of the site-built houses had ventilation rates below the ASHRAE recommended value. In both manufactured and site-built houses, the predominant airborne compounds were alpha-pinene, formaldehyde, hexanal, and acetic acid. Formaldehyde concentrations were below or near 50 ppb with a geometric mean value for all houses of 40 ppb. Similarities in the types of VOCs and in VOC concentrations indicated that indoor air quality in the houses was impacted by the same or similar sources. Major identified sources included plywood flooring, latex paint and sheet vinyl flooring. One site-built house was operated at ventilation rates of 0.14 and 0.32 h-1. VOC emission rates calculated at the two conditions agreed within +/- 10% for the most volatile compounds. Generally, the ratios of emission rates at the low and high ventilation rates decreased with decreasing compound volatility. Changes in VOC emission rates in the manufactured houses over 2-9.5 months after installation varied by compound. Only several compounds showed a consistent decrease in emission rate over this period.  相似文献   

8.
Volatile organic compounds (VOCs) as a non-negligible aircraft cabin air quality (CAQ) factor influence the health and comfort of passengers and crew members. On-board measurements of carbonyls (short-chain (C1-C6)) and other volatile organic compounds (VOCs, long-chain (C6-C16)) with a total of 350 samples were conducted in 56 commercial airliner cabins covering 8 aircraft models in this study. The mean concentration for each individual carbonyl compound was between 0.3 and 8.3 μg/m3 (except for acrolein & acetone, average = 20.7 μg/m3) similar to the mean concentrations of other highly detected VOCs (long-chain (C6-C16), 97% of which ranged in 0–10 μg/m3) in aircraft cabins. Formaldehyde concentrations in flights were significantly lower than in residential buildings, where construction materials are known formaldehyde sources. Acetone is a VOC emitted by humans, and its concentration in flights was similar to that in other high-occupant density transportation vehicles. The variation of VOC concentrations in different flight phases of long-haul flights was the same as that of CO2 concentration except for the meal phase, which indicates the importance of cabin ventilation in diluting the gaseous contaminants, while the sustained and slow growth of the VOC concentrations during the cruising phase in short-haul flights indicated that the ventilation could not adequately dilute the emission of VOCs. For the different categories of VOCs, the mean concentration during the cruising phase of benzene series, aldehydes, alkanes, other VOCs (detection rate > 50%), and carbonyls in long-haul flights was 44.2 µg/m3, 17.9 µg/m3, 18.6 µg/m3, 31.5 µg/m3, and 20.4 µg/m3 lower than those in short-haul flights, respectively. Carbonyls and d-limonene showed a significant correlation with meal service (< 0.05). Unlike the newly decorated rooms or new vehicles, the inner materials were not the major emission sources in aircraft cabins. Practical Implications.
  • The on-board measurements of 56 flights enrich the VOC database of cabin environment, especially for carbonyls. The literature review of carbonyls in the past 20 years contributes to the understanding the current status of cabin air quality (CAQ).
  • The analysis of VOC concentration variation for different flight phases, flight duration, and aircraft age lays a foundation for exploring effective control methods, including ventilation and purification for cabin VOC pollution.
  • The enriched VOC data is helpful to explore the key VOCs of aircraft cabin environment and to evaluate the acute/chronic health exposure risk of pollutants for passengers and crew members.
  相似文献   

9.
This report presents the results of investigations on the indoor air quality of common Japanese detached houses. It is necessary to control the emission rates from the interior materials and the ventilation rates to keep indoor concentration of VOC enough low. And it is also necessary to consider the influence of the pollution sources in the concealed spaces for better indoor air quality in some kinds of building structures and some kinds of ventilation systems. In this study the influences of the concealed pollution sources upon the indoor concentrations of pollutants were investigated using three detached houses with four ventilation systems and the following results were obtained. When the ventilation system was changed from the air-supply type to the air-exhaust type, the indoor concentrations of formaldehyde increased. The infiltration ratios: the ratios of the infiltration rate to the indoor space toward the emission rate of a pollutant in the concealed space were measured using the tracer-gas method. The ratios from the beam spaces and the partition were about 100% in most cases. The ratios from the crawl space under the first floor and the truss space under the roof were lower than those from the beam space and partitions in most cases, because those spaces have ventilation openings. But the ratio from the crawl space reached about 100% in the house without ventilation openings at the crawl space. And even in the house with ventilation openings at crawl space, the ratio reached 50% in the house with the exhaust-ventilation system. Therefore, it became clear that the use of the medicine to prevent the deterioration of the wooden structure and the white ants in the crawl spaces must be limited. The ratio from the envelope wall was changed with the pressure difference between inside and outside. These results showed that it is necessary to prevent infiltration from the concealed spaces and to control the emission rate from the concealed pollution sources.  相似文献   

10.
A PV system enhanced the performance of roof solar collector   总被引:1,自引:0,他引:1  
A simple PV ventilation system was used to enhance the performance of roof solar collector (RSC) for reducing heat gain and increasing the ventilation rate inside houses. The RSC is composed of CPAC Monier concrete tiles at the outer side, air gap and gypsum board at the house side. The PV system consists of one PV panel (27 Wp), a DC electrical fan (7.3 W) installed in the gap of RSC and a control unit.

Field testing results showed that the average temperature gradient between CPAC tiles, gypsum board and room was low, about 7°C, demonstrating a high heat gain reduction. The temperature of gypsum board was very close to the indoor temperature. The average PV powered air flow rate and the corresponding air change per unit RSC were about 100–250 m3/h and 3–8 ACH, respectively. Such rates are 2–4 times higher than those obtained with the natural ventilation induced by RSC. In addition, PV-powered RSC is an interesting option in the sense that it promotes solar energy and conserve energy.  相似文献   


11.
Dan Norbck 《Indoor air》1995,5(4):237-246
There is a growing concern about indoor air quality (IAQ) in schools. We have studied relations between subjective indoor air quality (SIAQ) and measured IAQ among school personnel (N = 97) in six mid-Swedish primary schools. Information on SIAQ and the psychosocial work environment was measured by a self-administered questionnaire, using analogue rating scales. Indoor exposures were quantified by hygienic measurements. Perception of high room temperature was related to a poor climate of cooperation, fleecy wall materials, and the concentration of volatile organic compounds (VOC), including xylene, limonene, and butanols. Perception of air dry-ness was related to atopy, work stress, poor climate of cooperation, high room temperature, low air humidity, and high VOC concentration, including, limonene, and n-alkanes. Perception of dusty air was related to work stress, the role of schoolteacher, and exposure to 2-ethyl-1-hexanol. No relations were found between SIAQ and CO2, building age, or respirable dust. To achieve a good SIAQ, room temperature should be kept at a maximum of 22°C, and exposure to VOCs and fleecy materials should be minimized. Finally, a sound psychosocial work climate is essential for the perception of a good physical indoor climate.  相似文献   

12.
Measurements were taken in new US residences to assess the extent to which ventilation and source control can mitigate formaldehyde exposure. Increasing ventilation consistently lowered indoor formaldehyde concentrations. However, at a reference air exchange rate of 0.35 h?1, increasing ventilation was up to 60% less effective than would be predicted if the emission rate were constant. This is consistent with formaldehyde emission rates decreasing as air concentrations increase, as observed in chamber studies. In contrast, measurements suggest acetaldehyde emission was independent of ventilation rate. To evaluate the effectiveness of source control, formaldehyde concentrations were measured in Leadership in Energy and Environmental Design (LEED)‐certified/Indoor airPLUS homes constructed with materials certified to have low emission rates of volatile organic compounds (VOC). At a reference air exchange rate of 0.35 h?1, and adjusting for home age, temperature and relative humidity, formaldehyde concentrations in homes built with low‐VOC materials were 42% lower on average than in reference new homes with conventional building materials. Without adjustment, concentrations were 27% lower in the low‐VOC homes. The mean and standard deviation of formaldehyde concentration was 33 μg/m3 and 22 μg/m3 for low‐VOC homes and 45 μg/m3 and 30 μg/m3 for conventional.  相似文献   

13.
Hotel housekeepers represent a large, low-income, predominantly minority, and high-risk workforce. Little is known about their exposure to chemicals, including volatile organic compounds (VOCs). This study evaluates VOC exposures of housekeepers, sources and factors affecting VOC levels, and provides preliminary estimates of VOC-related health risks. We utilized indoor and personal sampling at two hotels, assessed ventilation, and characterized the VOC composition of cleaning agents. Personal sampling of hotel staff showed a total target VOC concentration of 57 ± 36 µg/m3 (mean ± SD), about twice that of indoor samples. VOCs of greatest health significance included chloroform and formaldehyde. Several workers had exposure to alkanes that could cause non-cancer effects. VOC levels were negatively correlated with estimated air change rates. The composition and concentrations of the tested products and air samples helped identify possible emission sources, which included building sources (for formaldehyde), disinfection by-products in the laundry room, and cleaning products. VOC levels and the derived health risks in this study were at the lower range found in the US buildings. The excess lifetime cancer risk (average of 4.1 × 10−5) still indicates a need to lower exposure by reducing or removing toxic constituents, especially formaldehyde, or by increasing ventilation rates.  相似文献   

14.
利用自制小型环境箱实验研究了面漆挥发性有机物(VOCs)的散发特性。研究结果表明,气流速率、涂层厚度、基底材料的特性以及基底的边缘效应等对面漆VOCs的散发特性有重要影响。高气流速度可以提高VOCs浓度的衰减速率,缩短面漆VOCs的蒸发时间;涂层越厚,环境箱内VOCs浓度越高,VOCs的蒸发时间越长:采用孔隙率较低的材料作基底,基底内VOCs的残存量低,可减轻建筑物使用后的VOCs低浓度污染。基底“边缘效应”可明显改变VOCs浓度随时间的变化关系。  相似文献   

15.
There are many mass-transfer models for predicting VOC emissions from building materials described in the literature. In these models, the volatile organic compound (VOC) emission rate and its concentration in a chamber or a room are usually obtained by analytical method or numerical method. Although these methods demonstrate some salient features, they also have some flaws, e.g., for analytical method the solutions of both room or chamber VOC concentration and building material VOC emission rate are constituted of the sum of an infinite series, in which additional computation for finding roots to a transcendental function is necessary, but sometimes quite complicated. Besides, when it is applied in complex cases such as multilayer emission with internal reaction, the solution is very difficult to get; for conventional numerical methods such as finite difference method, discrete treatment of both time and space may cause calculation errors. Considering that, the state-space method widely used in modern automation control field and the heat transfer field is applied to simulate VOC emissions from building materials. It assumes that a slab of building material is composed of a number of finite layers, in each of which the instantaneous VOC concentration is homogenous during the entire process of emission, while the time is kept continuous. Based on this assumption we can predict both the VOC emissions rate and the concentrations of VOCs in the air of a chamber or room. The method is generally applied to simulate VOC emissions from arbitrary layers of building materials, and the solution is explicit and simple. What's more, the method can be applied to the cases where a reaction producing/removing VOC in building materials exists. For some specific cases the method is validated using the experimental data and the analytical solutions in the literature. The method provides a simple but powerful tool for simulating VOC emissions from building materials, which is especially useful in developing indoor air quality (IAQ) simulation software.  相似文献   

16.
We report simultaneous laboratory measurements of seismic velocities and fluid permeability on lava flow basalt from Etna (Italy) and columnar basalt from Seljadur (Iceland). Measurements were made in a servo-controlled steady-state-flow permeameter at effective pressures from 5–80 MPa, during both increasing and decreasing pressure cycles. Selected samples were thermally stressed at temperatures up to 900 °C to induce thermal crack damage. Acoustic emission output was recorded throughout each thermal stressing experiment.

At low pressure (0–10 MPa), the P-wave velocity of the columnar Seljadur basalt was 5.4 km/s, while for the Etnean lava flow basalt it was only 3.0–3.5 km/s. On increasing the pressure to 80 MPa, the velocity of Etnean basalt increased by 45%–60%, whereas that of Seljadur basalt increased by less than 2%. Furthermore, the velocity of Seljadur basalt thermally stressed to 900 °C fell by about 2.0 km/s, whereas the decrease for Etnean basalt was negligible. A similar pattern was observed in the permeability data. Permeability of Etnean basalt fell from about 7.5×10−16 m2 to about 1.5×10−16 m2 over the pressure range 5–80 MPa, while that for Seljadur basalt varied little from its initial low value of 9×10−21 m2. Again, thermal stressing significantly increased the permeability of Seljadur basalt, whilst having a negligible effect on the Etnean basalt. These results clearly indicate that the Etnean basalt contains a much higher level of crack damage than the Seljadur basalt, and hence can explain the low velocities (3–4 km/s) generally inferred from seismic tomography for the Mt. Etna volcanic edifice.  相似文献   


17.
Lee CS  Haghighat F  Ghaly WS 《Indoor air》2005,15(3):183-196
Building materials can strongly affect indoor air quality. Porous building materials are not only sources of indoor air pollutants such as volatile organic compounds (VOC) but they are also strong sinks of these pollutants. The knowledge of VOC transfer mechanisms in these materials is an important step for controlling the indoor VOC concentration levels, and for determining the optimum ventilation requirements for acceptable IAQ. This study provides a theoretical investigation of primary and secondary VOC source and sink behavior of porous building materials. A new analytical model was developed based on the fundamental theories of mass transfer mechanisms in porous materials. The proposed model considers both primary and secondary source/sink behavior for the first time. The former refers to the transfer of gas-phase and/or physically adsorbed VOC, while the latter refers to the generation or elimination of VOC within the solid because of chemical reactions like oxidation, hydrolysis, chemical adsorption, etc. The proposed model was assessed with experimental data, namely emission tests of carpets and sorption tests of wood chipboard. It was demonstrated that, unlike the existing analytical models, the proposed analytical model could simultaneously account for the effect of air velocity on both VOC source as well as sink behavior. Case studies were then carried out for secondary VOC source behavior. Due to the lack of experimental studies on mechanisms of secondary behavior, hypothetical generation functions were implemented. It was demonstrated that the proposed analytical model is suitable for describing various mechanisms involved in the secondary behavior due to the little limitations imposed on the generation/elimination term. When VOC generation takes place at the material-air interface, the simulation shows that although the primary emission is not affected by air velocity, the secondary emission, however, is clearly affected. This behavior agrees with the available experimental findings on secondary emissions. PRACTICAL IMPLICATION: The analytical model presented in this paper can predict both primary and secondary VOC source (emission) or sink (sorption) behavior of porous building materials. Since the model considers diffusion and adsorption/desorption within the material, and convection over the material surface, the simulation using the model can readily provide the effects of material properties and airflow properties on the primary and/or the secondary behavior, hence, it can provide a better understanding on the mechanisms. This will enable us to keep the indoor VOC concentration within a desirable level.  相似文献   

18.
Park JS  Ikeda K 《Indoor air》2006,16(2):129-135
Indoor air organic compounds were continuously monitored during 3 years in new and older homes which were voluntarily selected throughout countries. The levels of volatile organic compounds (VOCs) in the new homes decreased markedly after 1 year, and steady emissions of VOCs were obtained in the initial months. Formaldehyde and a-pinene related to wooden materials need a longer flushing period than the other compounds in the new homes. The levels of the indoor air organic compounds in the older homes showed no significant fluctuation during the 3-year period. Decreases of the indoor-produced compounds in the new homes did not depend upon the ventilation systems. The results indicate that the indoor-produced compounds in the new homes will be more influenced by the aging decreases of emission source strengths than ventilation systems. The quantitative information on the trend of the indoor air organic compound levels will be useful for the risk assessment of indoor exposure to those compounds, and also for Japanese IAQ guidelines. PRACTICAL IMPLICATIONS: The initial levels of VOCs in the new homes decreased dramatically and were close to the mean values for the older homes after one year. The results suggest that steady emissions of VOCs are obtained within initial months. However, formaldehyde and a-pinene did not follow the trend for VOCs, particularly in the wooden framed houses. The results tend to suggest that formaldehyde and a-pinene related to wooden materials will need more long a flushing period than other compounds in the new homes. Decreasing tendency of indoor air organic compound levels in the new homes did not appear to show any dependency upon the ventilation systems over the whole period. Absence of data for ventilation rates in the houses dose not permit interpretation of the relation between ventilation rates and indoor air organic compound levels with statistical certainty, but the results suggest that indoor air organic compound levels in the homes will be more influenced by emission source strengths than ventilation systems. The levels of indoor air organic compounds in the new homes are sufficiently decreased according to the ageing decreases of organic compounds when the home is ventilated with adequate quantities.  相似文献   

19.
Metts TA  Batterman SA 《Indoor air》2007,17(5):362-371
If released in significant amounts, products formed by reactions between ozone (O3) and volatile organic compounds (VOCs) sorbed on activated carbon (AC) filters could degrade indoor air quality (IAQ). Heterogeneous reactions were investigated in laboratory experiments aimed at characterizing reaction products. Effluent air of AC loaded with limonene and exposed to O3 (5.8 ppm) yielded unreacted limonene (501+/-197 microg/m3), low levels of 4-acetyl-1-methylcyclohexene (AMCH) (20+/-2 microg/m3), and limonene oxides (25+/-7 microg/m3). Most of the O3-limonene products remained on the AC, and most (58%) of the limonene remained unreacted on the AC after exposure to a stoichiometric excess of O3 for 48 h. Thus, in addition to known homogenous reactions, O3-limonene reactions occur heterogeneously on AC but to a much lesser extent. However, the fate of 95% of the depleted limonene was not determined; much of the missing portion was attributed to desorption from the AC, but the formation of other secondary indoor air pollutants is possible. VOC-loaded AC air filters exposed to O3 seem unlikely, however, to constitute a significant emission source of reaction products. More studies are necessary to investigate other pollutants, effects of environmental conditions, and VOC releases from AC that may be enhanced by O3 exposure. PRACTICAL IMPLICATIONS: Reactions between ozone and certain volatile organic compounds such as limonene (a common ingredient of many consumer products) occurring on the surface of ventilation filters could impact indoor air quality if products are released in significant amounts. This study suggests that although very small amounts of limonene adsorbed on a filter will react with O3, ventilation filters are not likely to be significant sources of ozone oxidation products. More studies are needed to investigate whether ozone exposure enhances desorption of pollutants from ventilation filters and to measure the formation of formaldehyde and other products that are not easily retained by charcoal filters.  相似文献   

20.
The Murderkill River is a partially tidal body of water with summer-time 50-percentile freshwater flows ranging from 17.9 to 27.6ft3s−1 (0.5 to 0.77m3s−1) at a point coincident with the effluent discharge from the Kent County Regional Wastewater Treatment Plant (start-up late 1972). Chloride concentrations were determined over six summers to characterize river conditions prior to start-up of the 10-million gal day−1 (37.850 m3 day−1) (design) plant. Use of a one-dimensional steadystate model for a conservative substance shows that chloride values would be reduced by up to 20% at low water slack (LWS) periods for wastewater flows of 10 million gal day−1 (37,850 m3 day−1). The LWS chloride concentrations in the area of oyster production would be reduced to 3–6 ppt (5.9–10.8 ppt salinity) for wastewater loadings greater than 10 million gal day−1 (37,850 m3 day−1) . It is suggested that chloride additions in the treatment plant effluent be implemented to maintain minimum summertime low-water-slack levels of 5.6 ppt chloride (10 ppt salinity), consistent with a proper environment for oyster development.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号