首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Large-scale rotors in the paper and steel industry are called rolls. Rolls are reground at regular intervals and roundness measurements are made throughout the machining process. Measurement systems for roundness and diameter variation of large rolls (diameter <2000 mm) are available on the market, and generally use two to four sensors and a roundness measurement algorithm. These methods are intended to separate roundness of the rotor from its movement. The hybrid four-point method has improved accuracy, even for harmonic component amplitudes. For reliable measurement results, every measurement should be traceable with an estimation of measurement uncertainty. In this paper, the Monte-Carlo method is used for uncertainty evaluation of the harmonic components of the measured roundness profile under typical industrial conditions. According to the evaluation, the standard uncertainties for the harmonic amplitudes with the hybrid method are below 0.5 μm for the even harmonics and from 1.5 μm to 2.5 μm for the odd harmonics, when the standard uncertainty for the four probes is 0.3 μm each. The standard uncertainty for roundness deviation is 3.3 μm.  相似文献   

2.
A motorized 5 m tape comparator was constructed in TUBITAK UME for calibration of tapes and rules up to 5 m length in one set-up and further lengths in multiple set-ups. The system is a practical development and provides a cost effective solution for calibration of tapes in which the highest grade’s accuracy requirement in OIML R35-1 e.g. is 600 μm for 5 m length and 1100 μm for 10 m length. It is mainly composed of 6 m rail system, mechanical parts, optical units and an integrated 6 m incremental linear encoder as a reference measurement axis for traceable measurements. The rails are kinematically located on a heavy marble construction and a motorized carriage, which employs a camera for probing of the scales on the tapes, is moved along the rails during the measurement. The image of the scale taken by the camera is viewed on the monitor screen together with the running software. The operator can perform the probing process by simply moving the carriage over the measured scales (tapes or rules) using a joystick. The carriage movement is measured by the incremental linear encoder previously calibrated by a laser interferometer and the software automatically takes the measurement results from the incremental linear encoder, applies correction values previously defined and determines the length of the tapes and rules as well as deviations from nominal lengths. The estimated expanded uncertainty of the steel tape measurement is U = 54 μm in one set-up (for 5 m length) and U = 77 μm in two set-ups (for 10 m length) at the confidence level of approximately 95%. Uncertainty budget for calibration of the device itself and for calibration of the test tapes are explained in detail. The results of extensive experimental work and analysis are provided by demonstrating application of science and technology of measurement and instrumentation. Investigations for long term stability of the system are given with the reported test results for the years of 2003-2011 and participated intercomparison results to validate the device scientifically are illustrated.  相似文献   

3.
Tungsten-based microstructures have attracted great interest in many industrial advanced applications. Nevertheless, with a disadvantageous combination of high hardness, toughness and brittleness, the micro machining of pure tungsten poses significant difficulty. In this paper, an investigation into the wire electrochemical micro machining (WEMM) of pure tungsten at low alkaline electrolyte concentration and small pulse duration is presented. Under the optimal machining conditions, tungsten-based microstructures with a side gap of 4 μm, slit width of 18 μm and aspect ratio of 5.6, as well as with a side gap of 5 μm, slit width of 20 μm and aspect ratio of 15, were obtained. In order to improve productivity in the machining of multi-slit microstructures, multi-wire electrochemical micro machining of tungsten was introduced. Using a 3-wire electrode, a 9-slit microstructure with a slit width of approximately 24 μm was produced and the machining efficiency was improved by a factor of three. The results revealed that it was a promising method for the fabrication of tungsten-based periodic or quasi-periodic microstructures, such as the gratings used in the X-ray absorption contrast system of imaging.  相似文献   

4.
A displacement metrology and control system using an optical frequency comb generator and a dual Fabry-Perot cavity is developed with sub-nm accuracy. The optical frequency comb generator has expanded the displacement measurement range and the dual cavity system has suppressed the environmental fluctuation. We evaluated the absolute uncertainty of the developed displacement measurement system to be approximately 190 pm for the displacement of 14 μm and the accurate displacement control using a phase-locked loop was demonstrated with a resolution of approximately 24 pm.  相似文献   

5.
Bilateral comparisons of the calibration of low nominal capacity torque measuring devices (TMDs) were conducted between NMIJ and PTB for the first time. A 10 N m deadweight torque standard machine (TSM) newly developed at NMIJ was compared with PTB’s two TSMs with nominal capacities of 1 N m and 1 kN m, in the range from 0.1 N m to 10 N m. The transfer measurement devices used had nominal capacities of 1 N m and 10 N m. The comparisons were made using two calibration procedures: one based on the CCM.T-K2 Key Comparison procedure and the other according to the daily calibration procedure adopted at each institute. As a result, the torque realized by the TSM at NMIJ was shown to be equivalent to that realized by the two TSMs at PTB. In addition, it was confirmed that the daily calibration procedures of both institutes yielded consistent results in the calibration of low nominal capacity TMDs.  相似文献   

6.
This paper presents a new optical method of coordinate measuring machine (CMM) verification. The proposed system based on a single-mode fiber optical-comb pulsed interferometer with a ball lens of refractive index 2 employed as the target. The target can be used for absolute-length measurements in all directions. The laser source is an optical frequency comb, whose repetition rate is stabilized by a rubidium frequency standard. The measurement range is confirmed to be up to 10 m. The diagonals of a CMM are easier to verify by the proposed method than by the conventional artifact test method. The measurement uncertainty of the proposed method is also smaller than that of the conventional method because the proposed measurement system is less affected by air temperature; it achieves an uncertainty of approximately 7 μm for measuring lengths of 10 m. The experimental results show that the measurement accuracy depends on noise in the interference fringe, which arises from airflow fluctuations and mechanical vibrations.  相似文献   

7.
According to the aperture of the objectives, surfaces with steep topographies greater than approximate 25° are difficult or unable to measure with white light interferometry. Hence, an adaptive-orientation measurement is proposed by adjusting the incidence angle from 51° to 21°. In this study, a micro-grinding with #3000 diamond wheel V-tip was employed to fabricate the micro-pyramid-structured Si surface with 142 μm in depth and 38 nm in surface roughness. The objective is to evaluate the micro-profile accuracy of micro-ground Si surface. First, the four micro-ground surfaces of micro-pyramid-structured surface were measured along the adaptive orientation with an incidence angle, respectively; then iterative closest point (ICP) matching was used to reconstruct the whole micro-ground surface with four adaptive-orientation measured point clouds; finally, 3D reconstruction error and characterized profile error were investigated. It is shown that the ICP matching with denoising and finishing is valid to register four adaptive-orientation measured point clouds for reconstructing an integrated micro-ground surface. Moreover, a decrease in incidence angle to measured surfaces leads to a decrease in 3D reconstruction error, an increase in valid top-topographic point number and a decrease in characterized profile error. It is confirmed that the adaptive-orientation measurement with 21° incidence angle may enhance 3D reconstruction accuracy by about 35%, valid top-topographic point number by about 3 times and characterized profile accuracy by about 38% against the traditional measurement, respectively. The micro-ground form error of 5.5 μm and the characterized profile error of 6.0 μm may be achieved, respectively, thus the micro-grinding is valid for the precision micro-fabrication of micro-structured surface.  相似文献   

8.
An optical-comb pulsed interferometer was developed for the positioning measurements of the industrial coordinate measuring machine (CMM); a rough metal ball was used as the target of the single-mode optical fiber interferometer. The measurement system is connected through a single-mode fiber more than 100 m long. It is used to connect a laser source from the 10th floor of a building to the proposed measuring system inside a CMM room in the basement of the building. The repetition frequency of a general optical comb is transferred to 1 GHz by an optical fiber-type Fabry–Pérot etalon. Then, a compact absolute position-measuring system is realized for practical non-contact use with a high accuracy of measurement. The measurement uncertainty is approximately 0.6 μm with a confidence level of 95%.  相似文献   

9.
Self-assembly of components using liquid surface tension is an attractive alternative to traditional robotic pick-and-place as it offers high assembly accuracy for coarse initial part placement. One of the key requirements of this method is the containment of the liquid within a designated binding site. This paper looks to expand the applications of self-assembly and investigates the use of topographical structures applied to 3D printed micro components for self-assembly using liquid surface tension. An analysis of the effect of edge geometry on liquid contact angle was conducted. A range of binding sites were produced with varying edge geometries, 45–135°, and for a variety of site shapes and sizes, 0.4–1 mm in diameter, and 0.5 mm × 0.5 mm–1 mm × 1 mm square. Liquid water droplets were applied to the structures and contact angles measured. Significant increases in contact angle were observed, up to 158°, compared to 70° for droplets on planar surfaces, demonstrating the ability of these binding sites to successfully pin the triple contact line at the boundary. Three challenging self-assembly cases were examined: (1) linear initial component misplacement >0.5 mm, (2) angular misplacement of components, and (3) misplacement of droplet. Across all three assembly cases the lowest misalignments in final component position, as well as highest repeatability, were observed for structures with actual edge geometries <90° (excluding 45° nominal), where the mean magnitude of misalignment was found to be 31 μm with 14 μm standard deviation.  相似文献   

10.
This paper presents the statistical analysis applied into the shape of microlenses (MLs) for validating the high-reproducibility feature of their fabrication process. The MLs were fabricated with the AZ4562 photoresist, using photolithography and thermal reflow processes. Two types of MLs arrays were produced for statistical analysis purposes: the first with a cross-sectional diameter of 24 μm and the second with a cross-sectional diameter of 30 μm, and both with 5 μm spacing between MLs. In the case of 24 μm diameter arrays, the measurements showed a mean difference in diameter of 2.78 μm with a standard deviation (SD) of 0.22 μm (e.g., 2.78 ± 0.22 μm of SD) before the reflow, and 2.34 ± 0.35 μm of SD after the reflow. For the same arrays, the mean difference in height obtained was, comparatively to the 5.06 μm expected, 0.76 ± 0.10 μm of SD before the reflow and 1.91 ± 0.15 μm of SD after the reflow, respectively. A mean difference in diameter of 2.64 ± 0.41 μm of SD before the reflow, and 1.87 ± 0.34 μm of SD after the reflow was obtained for 30 μm diameter MLs arrays. For these MLs, a mean difference in height of 0.71 ± 0.12 μm of SD before the reflow and 2.24 ± 0.24 μm of SD after the thermal reflow was obtained, in comparison to the 5.06 μm of height expected to obtain. These results validate the requirement for reproducibility and opens good perspectives for applying this fabrication process on high-volume production of MLs arrays.  相似文献   

11.
The paper presents the accuracy and precision associated with realization of primary standard of sound using the reciprocity method. An experimental determination of the front cavity volume on Universal Measuring Machine has lead to reaffirmation of measurement uncertainty in pressure sensitivity determination to 0.04–0.15 dB in frequency range 31.5 Hz to 25 kHz. The reduced measurement uncertainty has also been validated from the results of the recent APMP Key comparison and also by comparison to the manufacturer’s value for LS2P microphones. The use of optical method for measuring the front cavity volume has refined the measurement methodology followed with adaptation of a self reliant, traceable and systematic measurement procedure in comparison to the earlier use of nominal values for sensitivity fitting exercise conducted on MP.EXE program. Consequently, the measurement uncertainty associated with the calibration of working standard microphones, multifunction acoustic calibrator and A-weighted sound pressure level measurements is also reduced.  相似文献   

12.
《Measurement》2007,40(7-8):797-802
A deadweight-type torque standard machine of 20 kN m rated capacity (20 kN m-DWTSM) has been designed and developed by the National Metrology Institute of Japan (NMIJ) at the National Institute of Advanced Industrial Science and Technology (AIST). Each uncertainty contribution comes mainly from the performance of each mechanical part of the 20 kN m-DWTSM. Authors evaluated the uncertainty of the mass of the linkage weights, local acceleration of gravity, influence of air buoyancy on deadweight loading, initial moment-arm length (including CMM measurement and temperature compensation), and sensitivity of the fulcrum. This report deals especially with evaluation of the remaining contributions, namely the influence of arm flexure and reference line variation at the end of the moment-arm on best measurement capability (BMC). Estimation of BMC in the 20 kN m-DWTSM gave a relative expanded uncertainty of less than 7.0 · 10−5 (k = 2) for the calibration range from 200 N m to 20 kN m.  相似文献   

13.
Machine tool calibration is becoming recognised as an important part of the manufacturing process. The current international standards for machine tool linear axes calibration support the use of quasi-static calibration techniques. These techniques can be time consuming but more importantly a compromise in quality due to the practical restriction on the spatial resolution of target positions on the axis under test. Continuous motion calibration techniques have the potential to dramatically increase calibration quality. Through taking several measurement values per second while the axis under test is in motion, it is possible to measure in far greater detail. Furthermore, since machine tools normally operate in dynamic mode, the calibration data can be more representative if it is captured while the machine is in motion. The drawback to measuring the axis while in motion is the potential increase in measurement uncertainty. In the following paper, different methods of continuous motion calibration are discussed. A time-based continuous motion solution is proposed as well as a novel optimisation and correlation algorithm to accurately fuse the data taken from quasi-static and continuous motion measurements. The measurement method allows for minimal quasi-static measurements to be taken while using a continuous motion measurement to enhance the calibration process with virtually no additional time constraints. The proposed method does not require any additional machine interfacing, making it a more readily accessible solution for widespread machine tool use than other techniques which require hardware links to the CNC. The result of which means a shorter calibration routine and enhanced results. The quasi-static and continuous motion measurements showed correlation to within 1 μm at the quasi-static measurement targets. An error of 13 μm was detailed on the continuous motion, but was missed using the standard test. On a larger, less accurate machine, the quasi-static and continuous motion measurements were on average within 3 μm of each other however, showed a standard deviation of 4 μm which is less than 1% of the overall error. Finally, a high frequency cyclic error was detected in the continuous motion measurement but was missed in the quasi-static measurement.  相似文献   

14.
In ISO 14405-1, the global sizes, such as least-squares diameter, minimum circumscribed diameter and maximum inscribed diameter are defined. The diameters above can be measured by using cylindrical coordinate measuring method like the circular section measuring method of cylindricity error. The determination method of the least-squares diameter was firstly given based on the cylindrical measuring system, and the optimization models of the minimum circumscribed diameter and the maximum inscribed diameter were built, respectively. The corresponding objective functions were unified as “minimax” expressions. For the four axis parameters of the cylinder with the minimum circumscribed diameter or the maximum inscribed diameter, the searching ranges of cylinder’s axis parameters for their optimal solutions were defined numerically. Thereafter, the genetic, steepest decent and BFGS-0.618 algorithms were introduced, and the optimization evaluation algorithms of two kinds of diameters mentioned above were given. Based on many cylinders’ profiles obtained by the circular section measuring method on a measuring instrument of cylinder’s global sizes which was developed by Zhongyuan University of Technology, Zhengzhou, China. The accuracy, efficiency and suitability of three optimization algorithms were investigated through the evaluation of a lot of the minimum circumscribed diameters and the maximum inscribed diameters. The measurement uncertainty of the global sizes for the cylindrical specimen was analyzed, and the measurement uncertainties of the sizes in the radial and z directions are ±0.95 μm and ±0.5 μm, respectively. The total measurement uncertainties of the global sizes of the cylindrical specimens with the specifications of ϕ10 × 120 mm and ϕ100 × 300 mm are ±3.8 μm and ±5.7 μm, respectively. The investigation results showed that for the evaluation of the globe sizes, any one of three algorithms above is not absolutely prior to the other two algorithms while considering both evaluation accuracy and efficiency, and the difference of their evaluation results do not exceed 0.5 μm. On the other hand, many points between the maximum value and the least value do not affect the evaluation results in optimization process. For improving the evaluation efficiency, by de-selecting those points while considering the characteristic parameter was also studied based on the statistic method and experiment. Coefficient t should be less than 0.3 to ensure the evaluation accuracy. This research may be useful for developing the next generation measurement instrument for the global sizes and the way forward for the digital manufacturing.  相似文献   

15.
Wear measurement implies the need for comparative measurements based on a reference frame. In this study, part of a tooth surface (common area) is proposed to be a reference frame for the comparative measurement. A registration procedure applies an iterative closest point algorithm for the least square best fit of the two surfaces on this common area. When the common area matches the best fit condition, the difference at the remaining part of the tooth surface represents changes between the two surfaces; in this case signifying tooth wear.The minimum requirements to verify tooth wear results are a three quadrant spherical surface of a molar tooth to be common area, and the fit of the common area needs to be less than 10 μm, to achieve the sensitivity of wear measurement up to the 100 μm level on the occlusal tooth surface. Incise apparatus was used for the digitisation of the tooth surface. Cloud, a 3-D image analysis software package was utilised for visualisation, registration and image analysis. A mathematical scrutiny was applied to validate the findings in theory. The proposed methodology is proven to be adequate to quantify tooth wear.  相似文献   

16.
A compact and inexpensive iodine-stabilized diode laser system with an output at 531 nm has been applied to long gauge block measurements. Although the optical frequency of the output beam was widely modulated (modulation width of ∼22 MHz), the coherence length and interference phase stability are sufficiently long and high, respectively, for the interferometric measurement of long gauge blocks of up to 1000 mm in length. The effective uncertainty of laser frequency in the interferometric measurement was theoretically and experimentally confirmed to be less than 10−9.  相似文献   

17.
A subpixel edge location method based on orthogonal Jacobi–Fourier moments is proposed in this paper to improve the performance of optical fiber spherical coupling probe during dimensional measurement of micro-cavities with high aspect ratio. The effectiveness of the proposed method is proved through the performance test of a micro-hole measuring machine with optical spherical coupling probe. Test results indicate that a blind micro-hole of 400 μm in diameter can be experimentally measured at the depth of 2000 μm with a repeatability of 40 nm and an extremity resolution of 42 nm.  相似文献   

18.
《Wear》2006,260(4-5):538-548
Roughness of disk media influences the tribological interaction of head-disk interfaces, especially when the intended flying-height is below 5 nm that is required to achieve extremely high-density recording (EHDR). Roughness parameters such as the root-mean-square (RMS) amplitude, however, are influenced by the scale of measurement, such as the scan size. Effects related to scale of measurement such as varying the scan size were investigated and means to reduce such effects were proposed by establishing an “ad hoc” digital filtering procedure. Two types of magnetic disks intended for EHDR were measured by an atomic force microscope (AFM) at various scan dimensions ranging from 0.5 μm × 0.5 μm to 112 μm × 112 μm. The proposed filtering method used the RMS values as a filter design parameter for choosing the appropriate high-pass cutoff wavelength for each scan size. The study revealed the existence of a unique cutoff wavelength that would identify different wavelength regimes and the associated critical scan size in each disk. To substantiate the effectiveness of the proposed filtering method in reducing the scale of measurement effects related to the scan size, other roughness parameters were also calculated subsequent to the filtering procedure. It was found that the proposed filtering scheme effectively reduced the scale of measurement effects in the amplitude parameters (e.g., RMS and the ten-point height variation) and the functional parameters (e.g., material and core void volumes). These parameters exhibited steady-state trends with respect to increasing scan size, indicating reduced scale of measurement effects.  相似文献   

19.
Two miniaturized liquid film sensors (MLFS) based on electrical conductance measurement have been developed and tested. The sensors are non-intrusive and produced with materials and technologies fully compatible and integrable with standard microfluidics. They consist of a line of 20 electrodes with a purpose-designed shape, flush against the wall, covering a total length of 5.00 and 6.68 mm. The governing electronics achieve 10 kHz of time resolution. The electrode spacing of the two sensors is 230 μm and 330 μm, which allows measurements of liquid films up to 150 μm and 400 μm for sensors MLFSA and MLFSB, respectively. The sensor characteristics were obtained by imposing static liquid films of known thickness on top of the actual sensor. Further dynamic measurements of concurrent air-water flow in a horizontal microchannel were performed. The line of electrodes is placed across the flow direction with an angle of 3.53° from the direction of flow, allowing for a spatial resolution perpendicular to the flow of 14.2 μm for sensor MLFSA and 20.5 μm for sensor MLFSB. The high time and spatial resolution allows for fast and accurate detection of the presence of bubbles, and even measurement of film thickness and bubble velocity. Further information, such as the bubble shape, can be gathered based on the shape of the liquid layer underneath the bubble, which is particularly important for heat transfer studies in microchannels.  相似文献   

20.
This paper proposes a non-contact pulsed interferometer for dimensional metrology using the repetition frequency of an optical frequency comb. A compact absolute-length measuring system is established for practical non-contact measurement based on a single-mode fiber interferometer. The stability and accuracy of the measurements are compared with those from a commercial incremental laser interferometer. The drifts of both systems have the same tendency and a maximum difference is approximately 0.1 μm. Subsequently, preliminary absolute-length measurements up to 1.5 m were measured. The signal-to-noise ratios of the small signals are improved by a frequency-selective amplifier. It is apparent that the noise is rejected, and the intensity of the interference fringes is amplified, achieving a maximum standard deviation of measurement approximately 1 μm. The proposed technique can provide sufficient accuracy for non-contact measurement in applications such as a simple laser-pulse tracking system.  相似文献   