首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 703 毫秒
1.
An optical-comb pulsed interferometer was developed for the positioning measurements of the industrial coordinate measuring machine (CMM); a rough metal ball was used as the target of the single-mode optical fiber interferometer. The measurement system is connected through a single-mode fiber more than 100 m long. It is used to connect a laser source from the 10th floor of a building to the proposed measuring system inside a CMM room in the basement of the building. The repetition frequency of a general optical comb is transferred to 1 GHz by an optical fiber-type Fabry–Pérot etalon. Then, a compact absolute position-measuring system is realized for practical non-contact use with a high accuracy of measurement. The measurement uncertainty is approximately 0.6 μm with a confidence level of 95%.  相似文献   

2.
The presented 3D-ball plate is used for testing machine tools with a workspace of 500 mm × 500 mm × 320 mm. The artefact consists of a 2D-ball plate which is either located by a kinematic correct coupling on a base plate or on a spacer. The spacers are placed between the base plate and the ball plate and are also kinematic coupled to the other elements of the artefact. The kinematic couplings provide a high repeatability of the measurement setup. Because of the specific application the known calibration procedures for 2D-ball plates are not applicable.A calibration method for the pseudo-3D-artefact on a coordinate measuring machine (CMM) is presented, with the aim to minimise the influence of geometric CMM errors. Therefore a computer simulation is used to analyse the effects of these disturbing errors on the calibration of the ball plate and the spacers. Using a reversal method, the plate is measured at four different horizontal positions after rotating the ball plate around its vertical axis. A couple of the CMM errors, e.g., a squareness error C0Y between the X- and Y-axis of the CMM, can be eliminated by that method—others have to be determined with additional measurements, e.g., the positioning errors EXX or EYY of the X- and Y-axis, respectively. The paper also contains a measurement uncertainty estimation for the calibration by use of experiments, tolerances and Monte Carlo-simulations. The achieved uncertainty for ball positions in the working volume is less than 2.1 μm (coverage factor k = 2).  相似文献   

3.
A subpixel edge location method based on orthogonal Jacobi–Fourier moments is proposed in this paper to improve the performance of optical fiber spherical coupling probe during dimensional measurement of micro-cavities with high aspect ratio. The effectiveness of the proposed method is proved through the performance test of a micro-hole measuring machine with optical spherical coupling probe. Test results indicate that a blind micro-hole of 400 μm in diameter can be experimentally measured at the depth of 2000 μm with a repeatability of 40 nm and an extremity resolution of 42 nm.  相似文献   

4.
The paper presents the accuracy and precision associated with realization of primary standard of sound using the reciprocity method. An experimental determination of the front cavity volume on Universal Measuring Machine has lead to reaffirmation of measurement uncertainty in pressure sensitivity determination to 0.04–0.15 dB in frequency range 31.5 Hz to 25 kHz. The reduced measurement uncertainty has also been validated from the results of the recent APMP Key comparison and also by comparison to the manufacturer’s value for LS2P microphones. The use of optical method for measuring the front cavity volume has refined the measurement methodology followed with adaptation of a self reliant, traceable and systematic measurement procedure in comparison to the earlier use of nominal values for sensitivity fitting exercise conducted on MP.EXE program. Consequently, the measurement uncertainty associated with the calibration of working standard microphones, multifunction acoustic calibrator and A-weighted sound pressure level measurements is also reduced.  相似文献   

5.
This paper proposes a non-contact pulsed interferometer for dimensional metrology using the repetition frequency of an optical frequency comb. A compact absolute-length measuring system is established for practical non-contact measurement based on a single-mode fiber interferometer. The stability and accuracy of the measurements are compared with those from a commercial incremental laser interferometer. The drifts of both systems have the same tendency and a maximum difference is approximately 0.1 μm. Subsequently, preliminary absolute-length measurements up to 1.5 m were measured. The signal-to-noise ratios of the small signals are improved by a frequency-selective amplifier. It is apparent that the noise is rejected, and the intensity of the interference fringes is amplified, achieving a maximum standard deviation of measurement approximately 1 μm. The proposed technique can provide sufficient accuracy for non-contact measurement in applications such as a simple laser-pulse tracking system.  相似文献   

6.
A displacement metrology and control system using an optical frequency comb generator and a dual Fabry-Perot cavity is developed with sub-nm accuracy. The optical frequency comb generator has expanded the displacement measurement range and the dual cavity system has suppressed the environmental fluctuation. We evaluated the absolute uncertainty of the developed displacement measurement system to be approximately 190 pm for the displacement of 14 μm and the accurate displacement control using a phase-locked loop was demonstrated with a resolution of approximately 24 pm.  相似文献   

7.
Phase noise is an important parameter to characterise the frequency stability of oscillators and synthesised signal generators. Accurate measurement of phase noise is required for various applications in radar, communication and navigation systems. A single-channel phase-detector based phase noise measurement system is described. The system’s measurement errors and uncertainties have been analysed in details. The expanded uncertainty is about 2.7 dB for calibrating phase noise of a signal generator at 0.001–1.6 GHz for frequency offsets from 1 Hz to 100 kHz. The uncertainty budget for measuring a signal generator’s phase noise at 640 MHz is also presented.  相似文献   

8.
《Measurement》2007,40(7-8):797-802
A deadweight-type torque standard machine of 20 kN m rated capacity (20 kN m-DWTSM) has been designed and developed by the National Metrology Institute of Japan (NMIJ) at the National Institute of Advanced Industrial Science and Technology (AIST). Each uncertainty contribution comes mainly from the performance of each mechanical part of the 20 kN m-DWTSM. Authors evaluated the uncertainty of the mass of the linkage weights, local acceleration of gravity, influence of air buoyancy on deadweight loading, initial moment-arm length (including CMM measurement and temperature compensation), and sensitivity of the fulcrum. This report deals especially with evaluation of the remaining contributions, namely the influence of arm flexure and reference line variation at the end of the moment-arm on best measurement capability (BMC). Estimation of BMC in the 20 kN m-DWTSM gave a relative expanded uncertainty of less than 7.0 · 10−5 (k = 2) for the calibration range from 200 N m to 20 kN m.  相似文献   

9.
Machine tool calibration is becoming recognised as an important part of the manufacturing process. The current international standards for machine tool linear axes calibration support the use of quasi-static calibration techniques. These techniques can be time consuming but more importantly a compromise in quality due to the practical restriction on the spatial resolution of target positions on the axis under test. Continuous motion calibration techniques have the potential to dramatically increase calibration quality. Through taking several measurement values per second while the axis under test is in motion, it is possible to measure in far greater detail. Furthermore, since machine tools normally operate in dynamic mode, the calibration data can be more representative if it is captured while the machine is in motion. The drawback to measuring the axis while in motion is the potential increase in measurement uncertainty. In the following paper, different methods of continuous motion calibration are discussed. A time-based continuous motion solution is proposed as well as a novel optimisation and correlation algorithm to accurately fuse the data taken from quasi-static and continuous motion measurements. The measurement method allows for minimal quasi-static measurements to be taken while using a continuous motion measurement to enhance the calibration process with virtually no additional time constraints. The proposed method does not require any additional machine interfacing, making it a more readily accessible solution for widespread machine tool use than other techniques which require hardware links to the CNC. The result of which means a shorter calibration routine and enhanced results. The quasi-static and continuous motion measurements showed correlation to within 1 μm at the quasi-static measurement targets. An error of 13 μm was detailed on the continuous motion, but was missed using the standard test. On a larger, less accurate machine, the quasi-static and continuous motion measurements were on average within 3 μm of each other however, showed a standard deviation of 4 μm which is less than 1% of the overall error. Finally, a high frequency cyclic error was detected in the continuous motion measurement but was missed in the quasi-static measurement.  相似文献   

10.
Large-scale rotors in the paper and steel industry are called rolls. Rolls are reground at regular intervals and roundness measurements are made throughout the machining process. Measurement systems for roundness and diameter variation of large rolls (diameter <2000 mm) are available on the market, and generally use two to four sensors and a roundness measurement algorithm. These methods are intended to separate roundness of the rotor from its movement. The hybrid four-point method has improved accuracy, even for harmonic component amplitudes. For reliable measurement results, every measurement should be traceable with an estimation of measurement uncertainty. In this paper, the Monte-Carlo method is used for uncertainty evaluation of the harmonic components of the measured roundness profile under typical industrial conditions. According to the evaluation, the standard uncertainties for the harmonic amplitudes with the hybrid method are below 0.5 μm for the even harmonics and from 1.5 μm to 2.5 μm for the odd harmonics, when the standard uncertainty for the four probes is 0.3 μm each. The standard uncertainty for roundness deviation is 3.3 μm.  相似文献   

11.
In this investigation, a self-developed signal processing method for Fabry–Perot interferometer is proposed which can be utilized for high-speed dynamic displacement measurements, e.g. mechanical vibration measurements. The lookup table (LUT) integrated with the interference intensity equation has been employed for the interpolation processing of interference signals. With the aid of this method, the interpolation error has been reduced by 40% in comparison with that resulting from the commercial sinusoidal signal processing module. By operations of Fast Fourier Transform (FFT), the displacement measurement distribution can be converted into the frequency spectrum diagram. The interpolation resolution of the proposed interferometric displacement measurement system is about 0.1 nm. Experimental results demonstrate that this interferometer system is available for measuring frequencies till 2 kHz where its corresponding amplitude is 0.15 μm.  相似文献   

12.
For the purpose of measuring free form surfaces of some key parts in the aviation field accurately and effectively, such as blades, a non-contact optical coordinate measuring system is set up in the paper. A laser displacement sensor is mounted on the Z axis of a CMM via a turntable and adjusted to the suitable orientation according to the shape of the target surface. The combination of optical sensor and CMM can reach the full potential of them both. To enable the laser sensor to perform measurement in every direction, a calibration method used to determine the laser beam direction based on a standard sphere is proposed, the principle of which is analyzed in detail in the paper. In the calibration procedure, the sensor moves at an equal step along X, Y and Z axes respectively and then equation sets are established to calculate the unit direction vector of the line which the laser beam is on. In the process of solving the unknown quantities, a new parameter substitution method is applied. Finally, a gauging block and a sphere with known size are used to verify the method. As the experimental results show, the measuring errors in several directions are all smaller than 0.05 mm, which manifests that the calibration method proposed can meet the requirements of reverse engineering.  相似文献   

13.
In ISO 14405-1, the global sizes, such as least-squares diameter, minimum circumscribed diameter and maximum inscribed diameter are defined. The diameters above can be measured by using cylindrical coordinate measuring method like the circular section measuring method of cylindricity error. The determination method of the least-squares diameter was firstly given based on the cylindrical measuring system, and the optimization models of the minimum circumscribed diameter and the maximum inscribed diameter were built, respectively. The corresponding objective functions were unified as “minimax” expressions. For the four axis parameters of the cylinder with the minimum circumscribed diameter or the maximum inscribed diameter, the searching ranges of cylinder’s axis parameters for their optimal solutions were defined numerically. Thereafter, the genetic, steepest decent and BFGS-0.618 algorithms were introduced, and the optimization evaluation algorithms of two kinds of diameters mentioned above were given. Based on many cylinders’ profiles obtained by the circular section measuring method on a measuring instrument of cylinder’s global sizes which was developed by Zhongyuan University of Technology, Zhengzhou, China. The accuracy, efficiency and suitability of three optimization algorithms were investigated through the evaluation of a lot of the minimum circumscribed diameters and the maximum inscribed diameters. The measurement uncertainty of the global sizes for the cylindrical specimen was analyzed, and the measurement uncertainties of the sizes in the radial and z directions are ±0.95 μm and ±0.5 μm, respectively. The total measurement uncertainties of the global sizes of the cylindrical specimens with the specifications of ϕ10 × 120 mm and ϕ100 × 300 mm are ±3.8 μm and ±5.7 μm, respectively. The investigation results showed that for the evaluation of the globe sizes, any one of three algorithms above is not absolutely prior to the other two algorithms while considering both evaluation accuracy and efficiency, and the difference of their evaluation results do not exceed 0.5 μm. On the other hand, many points between the maximum value and the least value do not affect the evaluation results in optimization process. For improving the evaluation efficiency, by de-selecting those points while considering the characteristic parameter was also studied based on the statistic method and experiment. Coefficient t should be less than 0.3 to ensure the evaluation accuracy. This research may be useful for developing the next generation measurement instrument for the global sizes and the way forward for the digital manufacturing.  相似文献   

14.
A shear mode micro-probing system was constructed for gap measurement of a precision slot die coater with a nominal gap width of 90 μm and a length of 200 mm. A glass micro-stylus with a nominal tip ball diameter of 52.6 μm was oscillated by a tuning fork quartz crystal resonator with its oscillation direction parallel to the measurement surfaces. An on-line qualification setup was established to compensate for the influences of the uncertainty sources, including the water layers on the measurement surfaces. The measurement uncertainty of the measured gap width was estimated to be less than 100 nm.  相似文献   

15.
A compact and inexpensive iodine-stabilized diode laser system with an output at 531 nm has been applied to long gauge block measurements. Although the optical frequency of the output beam was widely modulated (modulation width of ∼22 MHz), the coherence length and interference phase stability are sufficiently long and high, respectively, for the interferometric measurement of long gauge blocks of up to 1000 mm in length. The effective uncertainty of laser frequency in the interferometric measurement was theoretically and experimentally confirmed to be less than 10−9.  相似文献   

16.
A motorized 5 m tape comparator was constructed in TUBITAK UME for calibration of tapes and rules up to 5 m length in one set-up and further lengths in multiple set-ups. The system is a practical development and provides a cost effective solution for calibration of tapes in which the highest grade’s accuracy requirement in OIML R35-1 e.g. is 600 μm for 5 m length and 1100 μm for 10 m length. It is mainly composed of 6 m rail system, mechanical parts, optical units and an integrated 6 m incremental linear encoder as a reference measurement axis for traceable measurements. The rails are kinematically located on a heavy marble construction and a motorized carriage, which employs a camera for probing of the scales on the tapes, is moved along the rails during the measurement. The image of the scale taken by the camera is viewed on the monitor screen together with the running software. The operator can perform the probing process by simply moving the carriage over the measured scales (tapes or rules) using a joystick. The carriage movement is measured by the incremental linear encoder previously calibrated by a laser interferometer and the software automatically takes the measurement results from the incremental linear encoder, applies correction values previously defined and determines the length of the tapes and rules as well as deviations from nominal lengths. The estimated expanded uncertainty of the steel tape measurement is U = 54 μm in one set-up (for 5 m length) and U = 77 μm in two set-ups (for 10 m length) at the confidence level of approximately 95%. Uncertainty budget for calibration of the device itself and for calibration of the test tapes are explained in detail. The results of extensive experimental work and analysis are provided by demonstrating application of science and technology of measurement and instrumentation. Investigations for long term stability of the system are given with the reported test results for the years of 2003-2011 and participated intercomparison results to validate the device scientifically are illustrated.  相似文献   

17.
There is a growing interest in accurately measuring the timing of the J peak of the ballistocardiogram (BCG) in order to obtain cardiovascular function markers non-invasively, especially in modern home healthcare applications. In this paper we have studied the effect that some common uncertainty sources have in the time measurement of the J peak. This is a necessary step towards the standardization of modern ballistocardiography systems equivalent to that available for ECG systems. We conclude that, to reduce J peak time uncertainty below the measured intrinsic uncertainty of about ±2 ms, the minimal bandwidth should be from 1.5 Hz to 22.5 Hz; the sampling frequency can be decreased up to 50 Hz when using cubic spline interpolation; 5 bits are required to quantify the signal, and signal-to-noise ratio (SNR) and signal-to-interference ratio (SIR) should be over 40 dB and 3 dB respectively.  相似文献   

18.
A simplified technique using short term Fourier transform to reduce the errors in distributed temperature measurement with a Raman scattering based optical fiber sensor system is presented. The two main sources of errors are differential attenuation to anti-Stokes and Stokes signal by fiber and local change in Stokes due to change in temperature. The proposed technique compensates these errors and extracts correct temperature profile in spite of practical difficulties encountered in applying the theoretical concept. Moreover proposed technique is less complex, self-reliant, can tolerate variation in laser power, requires less dead zone and suits automation using embedded solution. Results of measurement carried out, using the system developed at RRCAT, Indore, for two hot zones having spatial width of 1.9 m (kept at 56 °C) and 1.5 m (kept at 78 °C), located at 47 m and 85 m respectively, show that these parameters can be recovered with significantly small errors.  相似文献   

19.
In this study, a 5N  4 phase shifting algorithm comprising a polynomial window function and a discrete Fourier transform is developed to measure interferometrically the surface shape of a silicon wafer, with suppression of the coupling errors between the higher harmonics and the phase shift error. A new polynomial window function is derived on the basis of the characteristic polynomial theory by locating five multiple roots on the characteristic diagram. The characteristics of the 5N  4 algorithm are estimated with respect to the Fourier representation in the frequency domain. The phase error of the measurements performed using the 5N  4 algorithm is discussed and compared with those of measurements obtained using other conventional phase shifting algorithms. Finally, the surface shape of a 4-in. silicon wafer is measured using the 5N  4 algorithm and a wavelength tuning Fizeau interferometer. The accuracy of the measurement is discussed by comparing the amplitudes of the crosstalk noise calculated by other algorithms. The uncertainty of the entire measurement was 34 nm, better than that of any other conventional phase shifting algorithms.  相似文献   

20.
To solve the problem of calibrating the radius of a ball indenter in a hardness tester, a laser confocal radius measurement and calibration method for the ball indenter is proposed without separating the ball from the body of the indenter. The laser confocal radius measurement and calibration method uses the maximum of the confocal axial intensity curve to precisely identify the cat’s eye and confocal position of the test ball indenter. The distance between these two positions is then measured to achieve high-precision radius measurement. The theoretical analyses and experimental results indicate that the radius measurement uncertainty of the ball indenter with a diameter of 1.5875 mm is within 0.12 μm.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号