首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
A nationally consistent wave resource assessment is presented for Australian shelf (<300 m) waters. Wave energy and power were derived from significant wave height and period, and wave direction hindcast using the AusWAM model for the period 1 March 1997 to 29 February 2008 inclusive. The spatial distribution of wave energy and power is available on a 0.1° grid covering 110–156° longitude and 7–46° latitude. Total instantaneous wave energy on the entire Australian shelf is on average 3.47 PJ. Wave power is greatest on the 3000 km-long southern Australian shelf (Tasmania/Victoria, southern Western Australia and South Australia), where it widely attains a time-average value of 25–35 kW m?1 (90th percentile of 60–78 kW m?1), delivering 800–1100 GJ m?1 of energy in an average year. New South Wales and southern Queensland shelves, with moderate levels of wave power (time-average: 10–20 kW m?1; 90th percentile: 20–30 kW m?1), are also potential sites for electricity generation due to them having a similar reliability in resource delivery to the southern margin. Time-average wave power for most of the northern Australian shelf is <10 kW m?1. Seasonal variations in wave power are consistent with regional weather patterns, which are characterised by winter SE trade winds/summer monsoon in the north and winter temperate storms/summer sea breezes in the south. The nationally consistent wave resource assessment for Australian shelf waters can be used to inform policy development and site-selection decisions by industry.  相似文献   

2.
Rustu Eke  Ali Senturk 《Solar Energy》2012,86(9):2665-2672
In the present study, performance results of two double axis sun tracking photovoltaic (PV) systems are analyzed after one year of operation. Two identical 7.9 kWp PV systems with the same modules and inverters were installed at Mugla University campus in October 2009. Measured data of the PV systems are compared with the simulated data. The performance measurements of the PV systems were carried out first when the PV systems were in a fixed position and then the PV systems were controlled while tracking the sun in two axis (on azimuth and solar altitude angles) and the necessary measurements were performed. Annual PV electricity yield is calculated as 11.53 MW h with 1459 kW h/kWp energy rating for 28 fixed tilt angle for each system. It is calculated that 30.79% more PV electricity is obtained in the double axis sun-tracking system when compared to the latitude tilt fixed system. The annual PV electricity fed to grid is 15.07 MW h with 1908 kW h/kWp for the double axis sun-tracking PV system between April-2010 and March-2011. The difference between the simulated and measured energy values are less than 5%. The results also allow the comparison of different solutions and the calculation of the electricity output.  相似文献   

3.
Sanitary landfills have been and continue to be one of the most common ways to dispose of urban waste although such landfills inevitably generate waste management problems. Landfills are an important source of anthropogenic CH4 emissions. In this sense the European Union has passed regulations regarding the effective management of biogas within the framework of an EU policy for renewable energies. The sealed landfill analyzed in this study is an example of energy recovery, but in this case the biogas generated by the landfill is being re-used to produce electrical energy. This article presents the results of the economic viability study, which was carried out previous to the construction of the installation. The results based on the use of empirical and theoretical models show the biogas to have a 45% proportion of methane and an overall flowrate ranging from 250 to 550 N m3/h. It is presently being used to produce electricity amounting to approximately 4,500, 000 kW h/year. The economic viability of the installation was estimated by means of the Internal Recovery Rate (IRR) for an exploitation period of 7 years.  相似文献   

4.
Solar photovoltaic (PV) hybrid system technology is a hot topic for R&D since it promises lot of challenges and opportunities for developed and developing countries. The Kingdom of Saudi Arabia (KSA) being endowed with fairly high degree of solar radiation is a potential candidate for deployment of PV systems for power generation. Literature indicates that commercial/residential buildings in KSA consume an estimated 10–45% of the total electric energy generated. In the present study, solar radiation data of Dhahran (East-Coast, KSA) have been analyzed to assess the techno-economic viability of utilizing hybrid PV–diesel–battery power systems to meet the load requirements of a typical commercial building (with annual electrical energy demand of 620,000 kW h). The monthly average daily solar global radiation ranges from 3.61 to 7.96 kW h/m2. NREL's HOMER software has been used to carry out the techno-economic viability. The simulation results indicate that for a hybrid system comprising of 80 kWp PV system together with 175 kW diesel system and a battery storage of 3 h of autonomy (equivalent to 3 h of average load), the PV penetration is 26%. The cost of generating energy (COE, US$/kW h) from the above hybrid system has been found to be 0.149 $/kW h (assuming diesel fuel price of 0.1 $/L). The study exhibits that for a given hybrid configuration, the operational hours of diesel generators decrease with increase in PV capacity. The investigation also examines the effect of PV/battery penetration on COE, operational hours of diesel gensets for a given hybrid system. Emphasis has also been placed on unmet load, excess electricity generation, percentage fuel savings and reduction in carbon emissions (for different scenarios such as PV–diesel without storage, PV–diesel with storage, as compared to diesel-only situation), cost of PV–diesel–battery systems, COE of different hybrid systems, etc.  相似文献   

5.
《Applied Energy》2005,80(3):327-339
Biomass-energy systems are considered to be environmentally superior to traditional ones from the viewpoints of the CO2 mitigation and the effective utilization of resources. However, the energy cost of these systems tends to be higher than that of conventional fossil-fuel systems. Furthermore, the establishment of environmental business models is expected in the near future.In this paper, the environmental improvement and the economics of a biomass-energy system in a sawmill are analyzed by a comparison of a gasification-cogeneration system with a direct-combustion system using scrap-wood material as feedstock fuel. Especially, the break-even point for marketability of the business taking the surplus electric-power into consideration is estimated under the assumption of a renewable-energy purchase system, such as the renewable portfolio standard (RPS) implemented in Japan. Consequently, when biomass-related subsidies are applied, the break-even point of the purchase price of the electric power from the gasification cogeneration becomes 7.7  35.7 yen/kW h. Furthermore, if the construction cost decreases by 10%, the break-even point of the purchase price will be cheaper by about 7.4 yen/kW h.  相似文献   

6.
E.M. Nfah  J.M. Ngundam 《Solar Energy》2012,86(10):2935-2949
Photovoltaic hybrid systems (PVHS) with 2 days of energy autonomy are shown to be optimal options for the supply of the daily energy demands of 33 base transceiver stations of MTN Cameroon. PVHS were computed for all sites using the technical data for a 150 Wp mono-crystalline module, the site specific hourly load data, the average monthly solar radiation and temperature. Hourly solar radiation data for all sites were downloaded using the solar resource module of HOMER and geographical coordinates of the selected sites. The 3-hourly temperature data available on a website maintained NASA was used to generate average monthly hourly temperatures needed in the calculation of the output of solar modules. The energy costs and breakeven grid distances for possible power options were computed using the Net Present Value Technique and financial data for selected power system components. The results with a PV module cost of 7.5 €/Wp, a remote diesel price of 1.12 €/l, a general inflation rate of 5% and a fuel escalation of 10% showed that the annual operational times of the diesel generator were in the range 3–356 h/year with renewable energy fractions in the range 0.89–1.00. However, only 22 PVHS had two parallel battery strings as stipulated in the request for proposal launched by MTN Cameroon in 2008. The PV array sizes evaluated for the 22 PVHS were found to be the range 2.4–10.8 kWp corresponding to daily energy demands in the range 7.31–31.79 kW h/d. The energy costs and breakeven grid distances determined were in the ranges 0.81–1.32 €/kW h and 10.75–32.00 km respectively.  相似文献   

7.
In this paper, overall thermal energy and exergy analysis has been carried out for different configurations of hybrid photovoltaic thermal (PVT) array. The hybrid PVT array (10.08 m × 2.16 m) is a series and parallel combinations of 36 numbers of PV modules. A one-dimensional transient model for hybrid PVT array has been developed using basic heat transfer equations. On the basis of this transient model, an attempt has been made to select an appropriate hybrid PVT array for different climatic conditions (Bangalore, Jodhpur, New Delhi, and Srinagar) of India. On the basis of high grade energy (i.e. overall exergy gain), case-III has been selected as the most appropriate configuration because overall exergy for case-III is 12.9% higher than case-II. The overall thermal energy and exergy gain for Bangalore is 4.54 × 104 kW h and 2.07 × 104 kW h respectively which is highest in comparison to the other cities.  相似文献   

8.
In this paper, an exergoeconomic analysis has been carried out and on the basis of this analysis it has been concluded that in terms of energy saving the glazed hybrid photovoltaic thermal (PVT) module air collector offers a greater potential compared to PV module. The experimental validation for glazed hybrid PVT module air collector has also been performed and it has been observed that there is a good agreement between the theoretical and experimental values with correlation coefficient in range of 0.96–0.99 and root mean square percentage deviation in range of 2.38–7.46. The experiments have been carried out on clear days during the month July 2010 to June 2011. For the validation of theoretical results with experimental results, a typical day of winter month (December 08, 2010) and summer month (April 11, 2011) has been considered. An experimental uncertainty for December and April month is 11.6% and 2.1% respectively. The annual overall thermal energy and exergy gain are 1252.0 kWh and 289.5 kW h respectively. The annual net electrical energy savings by glazed hybrid PVT module air collector is 234.7 kW h.  相似文献   

9.
Analysis of the wind characteristics in Ras Benas city located on the east coast of Red Sea in Egypt using measured data (wind, pressure and temperature) and Weibull function were made.Statistical analysis model to evaluate the wind energy potential was introduced. According to the power calculations done for the site, the annual mean wind density is 315 kW/m2 at a height of 70 m above ground level. This station has a huge wind energy potential for electricity generation, especially during spring and summer seasons, comparing with some European countries.In addition, the monthly wind turbine efficiency parameter (ηmonthly) has been calculated by using a commercial wind turbine 1 MW with 70 m hub height to help designers and users in evaluating the potentialities and choosing the suitable wind turbine for the considered site. The use of wind turbine with capacity greater than 1000 kW at this station was recommended.Ras Benas station was selected to install 30 MW-wind farm consists of 20 commercial wind turbines (Nordex S 77) with hub heights and Rotor diameter were 100 and 77 m, respectively. This site has annual wind speed more than 9.8 m/s at 100 m height and enough area to locate these turbines.The estimated energy production using WASP Program of these wind farm was 130 GWh/year. Furthermore, the production costs was found 1.3€ cent/kWh, which is a competition price at the wind energy world market.  相似文献   

10.
This paper presents long-term analysis of wind speed data in terms of annual, seasonal and diurnal variations at Tindouf, which is situated on the south west region of Algeria. The wind speed data was collected over a period of 08 years between 1976 and 1984. The study showed that the long-term seasonal wind speeds were found to be relatively higher during September compared to other months. The diurnal change in long-term mean wind speed indicated that higher electricity could be produced during 09:00–18:00 h, which also coincides with higher electricity demand period. The annual wind energy production and capacity factor, obtained using wind speed frequency distribution and wind power curve of 1000 kW wind turbine and RETScreen software were found comparable with each other if unadjusted energy production values calculated by the software were used rather than the renewable energy delivered. Development of wind farm of 30 MW installed capacity at this site could result into avoidance of 23,252 tonnes/year of CO2 equivalents GHG from entering into the local atmosphere thus creating a clean and healthy atmosphere for local inhabitants.  相似文献   

11.
The advent of large samples of smart metering data allows policymakers to design Feed-in Tariffs which are more targeted and efficient. This paper presents a methodology which uses these data to design FITs for domestic scale grid-connected PV systems in Ireland. A sample of 2551 household electricity demand data collected at 1/2-hourly intervals, electricity output from a 2.82 kWp PV system over the same time interval as well as PV system costs and electricity tariffs were used to determine the required FIT to make it worthwhile for the households to invest in the PV system. The methodology shows that it is possible to design single, multiple and continuous FITs. Continuous FITs are the most efficient and result in no overcompensation to the housholder while single and multiple FITs are less efficient since they result in different levels of overcompensation. In the PV case study considered, it was shown that the use of three FITs (0.3170, 0.3315 and 0.3475 €/kW h) resulted in a 59.6% reduction in overcompensation compared to a single FIT of 0.3475 €/kW h; assuming immediate and complete uptake of the technology, this would result in NPV savings of over €597 m to the Irish government over a 25 year lifetime.  相似文献   

12.
The study presents modelling and analysis of air-cooled chiller system in an office building at Central Queensland University in Rockhampton, Australia. EnergyPlus, building energy simulation software, has been used to model and to simulate the energy savings. Base case cooling energy has been compared with measured data. The simulated results show a reasonable agreement with the measured data. As a passive cooling means, the effect of economiser usages and pre-cooling have been simulated and analysed to assess annual demand savings for an energy intensive office building at Rockhampton, Australia. It was found that implementation of the pre-cooling and economiser system could save 115 kW/m2/month and 72 kW/m2/month total cooling energy and 26 kW/m2/month and 42 kW/m2/month chiller energy, respectively.  相似文献   

13.
The present cost of fuel cells estimated at about $200 kW−1 is a major barrier for commercialization and use in automotive applications. In the United States the target costs for fuel cell systems for the year 2004 as formulated by PNGV are $50 kW−1. Lomax et al. have estimated the costs of polymer electrolyte membrane (PEM) fuel cells to be as low as $20 kW−1. These estimates are based on careful consideration of high volume manufacturing processes. Recently, Arthur D. Little (ADL) has estimated the cost of a fuel cell system for transportation at $294 kW−1. This estimate considers a fuel processor and directly related balance of plant components. The difference of the cost estimates results from the vastly different design assumptions. Both of these estimates are based on considering a single high volume of production, 500,000 fuel cells per year. This work builds on these earlier estimates by employing the methods of technical cost modeling and thereby including explicit consideration of design specifications, exogenous factor cost and processing and operational details. The bipolar plate is analyzed as a case study. The sensitivity of the costs to uncertainty in process conditions are explored following the ADL design. It is shown that the PNGV targets can only be achieved with design changes that reduce the quantity of material used. This might necessitate a reduction in efficiency from the assumed 80 mpg.  相似文献   

14.
A detailed analysis of the heating and cooling performance of environmental heat sources and sinks is presented for 12 low-energy buildings in Germany. In particular, the analysis focuses on the given temperature levels and the efficiency performance of the environmental heat sources and sinks in summer and winter. The investigated buildings employ environmental heat sources and sinks – such as the ground, groundwater, rainwater and the ambient air – in combination with thermo-active building systems (TABS). These concepts are promising approaches for slashing the primary energy use of buildings without violating occupant thermal comfort. A limited primary energy use of about 100 kW hprim/(mnet2 a) as a target for the complete building service technology (HVAC and lighting) was postulated for all buildings presented. With respect to this premise, comprehensive long-term monitoring in fine time-resolution occurred over a period from two to five years. An accompanying commissioning of the building performance took place. Measurements include water supply and return temperatures of the environmental heat sources/sinks, the generated heating and cooling energy, efficiencies of the system, and local climatic site conditions. The comparative evaluation of the systems in all buildings identifies weak points and success factors of the plant. Besides, it characterizes the single component and points out further potential for optimization measures. The annual efficiency performance of the geothermal heat sources and sinks results in a seasonal performance factor of 8–10 kW htherm/kW hend, where the end energy use is electricity. The ground, groundwater, rainwater and even the ambient air constitute efficient heat sources/sinks. Energy is needed only for distributing the heat and cold and not for its generation. The choice of suitable plant components, the accurate design of the hydraulic system and the correct dimension of the environmental heat source/sink play a central role in achieving higher efficiencies.  相似文献   

15.
Due to poverty, serious soil erosion and shortage of rural household energy in Loess Hilly Region, Gansu Province, China, excessive consumption of biofuel has become a critical factor underlying eco-environment degeneration. Data on rural household energy use was obtained by questionnaires, and based on substitutable analysis, environmental and economic costs under different energy consumption structures were estimated using a quantitative model. The results show that annual energy consumption per household is 2112.44 kgce and per capita 428.59 kgce, a low level. The total annual energy consumption cost per household is 1925.25 yuan, of which environmental cost is 621.13 yuan and economic cost 1304.52 yuan. Commercial energy has been used widely. The per household annual cash payment for commercial energy is 536.51 yuan, 8.69% of household net income. Exclusive use of solar energy and biogas obviously decreases energy consumption cost, cash payout and energy source availability being the main criteria for household energy choice. To compare with the actual structure of energy usage, there are clear differences in the total cost, environment cost, economic cost and cash payout for households among the four substitutable structures. All costs are lower when biogas and solar energy are used, so this structure is the primary direction that rural energy should adopt in the future.  相似文献   

16.
With the advent of the year 2008, Pakistan faces a gap of 4500 MW between the demand and supply of electricity, registering a shortfall of 40%. The article provides an overview of the key dimensions of the crisis, i.e. growing gap between demand and supply, diminishing indigenous oil and gas reserves, rising energy cost and security concerns. It also explores hydropower, solar energy, biomass and wind power as sustainable energy options for the country. In has been found that the total estimated hydropower potential is more than 42 GW out of which only 6.5 GW has been tapped so far. In terms of available solar energy Pakistan is amongst the richest countries in the world, having an annual global irradiance value of 1900–2200 kWh/m2. Despite that fact that the biomass plays an important role in the primary energy mix by contributing to 36% of the total supplies, it has not managed to break into the commercial energy market. Wind power, also been identified as a potential source of energy, is yet to take off.  相似文献   

17.
《Journal of power sources》2001,96(1):233-235
The use of metal based bipolar plates in polymer electrolyte membrane (PEM) fuel cells, with an active coating on titanium to reduce voltage losses due to the formation of passive layers has been demonstrated. Lifetime data in excess of 8000 h has been achieved and power densities in excess of 1.8 kW dm−3 and 1 kW kg−1 are predicted.  相似文献   

18.
19.
Spatial models of global insolation and photovoltaic electricity generation potential for Canada were developed. The main objective was to provide Canadians with an easily accessible, reliable tool for rapidly estimating the monthly and yearly electricity production potential of grid-connected photovoltaic systems anywhere in the country, and for assessing the dependence of production on location, time of year and array orientation. Monthly mean daily insolation data from 144 meteorological stations across Canada were used, along with data from an additional eight stations in Alaska to improve the models in that region. Several photovoltaic array orientations were considered, including South-facing arrays with latitude and vertical tilts and a sun-tracking orientation. Partial thin plate smoothing splines as implemented in ANUSPLIN were used to generate the spatial insolation models. The models were based on geographic position and a transform of monthly mean precipitation, the latter variable being a surrogate for cloudiness which affects surface insolation. Photovoltaic electricity generation (in kW h per kilowatt of photovoltaic installed power capacity) was estimated for each month and for the entire year from the insolation models by assuming international standard values for the performance ratio of photovoltaic systems. The yearly average root mean square predictive error (RTGCV) on the mean daily global insolation ranges between 0.75 (vertical tilt) and 1.43 MJ/m2 (sun-tracking orientation) (or about 4.7–9.0 kW h/kW in terms of PV potential), or from 5.6% to 6.9% of the mean. Ultimately insolation and photovoltaic potential were mapped over the country at a 300 arc seconds (~10 km) resolution. The maps are available on a Natural Resources Canada Website. This is an important new tool to help Canadians gain an overall perspective of Canada’s photovoltaic potential, and allow estimation of potential photovoltaic system electricity production at any chosen location.  相似文献   

20.
Replacing current generation with wind energy would help reduce the emissions associated with fossil fuel electricity generation. However, integrating wind into the electricity grid is not without cost. Wind power output is highly variable and average capacity factors from wind farms are often much lower than conventional generators. Further, the best wind resources with highest capacity factors are often located far away from load centers and accessing them therefore requires transmission investments. Energy storage capacity could be an alternative to some of the required transmission investment, thereby reducing capital costs for accessing remote wind farms. This work focuses on the trade-offs between energy storage and transmission. In a case study of a 200 MW wind farm in North Dakota to deliver power to Illinois, we estimate the size of transmission and energy storage capacity that yields the lowest average cost of generating and delivering electricity ($/MW h) from this farm. We find that transmission costs must be at least $600/MW-km and energy storage must cost at most $100/kW h in order for this application of energy storage to be economical.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号