Various types of external loop airlift contactors (ELALCs) were examined for their hydrodynamic and mass transfer behavior. The investigation covered a variety of design parameters including the length of connection tubes (Lc), height of riser and downcomer (Lh), and the airlift configurations while maintaining the ratio between downcomer and riser cross sectional area constant at 0.269. The results demonstrated that the behavior of the external loop airlift could be modified by adjusting the design and operating variables. In general, a faster liquid velocity led to a presence of lower gas holdup and gas–liquid mass transfer rate. Increasing Lc and Lh seemed to increase liquid velocity while decreasing the overall gas holdup and the overall volumetric mass transfer coefficient. Empirical correlations for the estimation of the system behavior were finally formulated.  相似文献   

2.
Fundamental characteristics of hydrodynamics and mass transfer have been measured in an air lift slurry reactor with a draft tube. The solid suspension capacity, i.e., the critical solid holdup, the gas holdup and the volumetric gas-liquid mass transfer coefficient were measured in the two draft tube columns of 0.1485 and 0.10?m in diameter. Four activated carbon beads ranging in size from 0.25 to 2.19?mm in average diameter were utilized as suspended solids in the experiments.

The critical solid holdup in the draft tube slurry column is found to be much greater than that in the conventional bubble column. An empirical correlation is developed to account for the critical solid holdup behavior in the draft tube column. The gas holdup in the draft tube column agrees well with that in the bubble column. The overall gas-liquid mass transfer coefficient, k1awas measured by the oxygen probe method. The effect of solid holdup on k1a is found to be negligible in the present system. The empirical equation is developed to correlate k1a in the draft tube slurry reactor.  相似文献   


3.
Local gas holdup (?) and interfacial area (a) at different axial locations of the riser and downcomer of a split-column airlift bioreactor were investigated using a sophisticated four-point optical probe. Such a type of a reactor has been found to outperform both bubble-column and draft-tube airlift bioreactors for culturing microalgae. The effect of superficial gas velocity (0.3–2.8 cm/s) on both gas holdup and interfacial area was studied using air–water system. It was found that both gas holdup and interfacial area significantly decrease from the top to the bottom of the downcomer for all superficial gas velocities, while their variation from the bottom to the top for the riser was found to be much less than that of the downcomer at the same superficial gas velocities. It was found that the interfacial area of the riser tends to increase by 35% from the bottom to the upper middle point of the column (6.15 Z/D from the bottom), then declines by 10% at the top location (7.7 Z/D from the bottom). Empirical correlations were obtained relating the gas holdup and specific interfacial area to superficial gas velocity of the riser and the downcomer of the bioreactor. It was found that the riser has to be represented as upper and lower halves to be best correlated, while the only upper half of the downcomer was successfully correlated. Having obtained variable interfacial area (a) at different locations of both the riser and the downcomer of the bioreactor, the local KLa consequently changes as a function of the location of the bioreactor and hence needs to be investigated locally as opposed to the current studies that have only measured and correlated the overall KLa.  相似文献   

4.
The hydrodynamic performance of three internal airlift reactor configurations was studied by the Eulerian–Eulerian k–ε model for a two‐phase turbulent flow. Comparative evaluation of different drag and lift force coefficient models in terms of liquid velocity in the riser and downcomer and gas holdup in the riser was highlighted. Drag correlations as a function of Eötvös number performed better results in comparison to the drag expressions related to Reynolds number. However, the drag correlation as a function of both Reynolds and Eötvös numbers fitted well with experimental results for the riser gas holdup and downcomer liquid velocity in configurations I and II. Positive lift coefficients increase the liquid velocity and decrease the riser gas holdup, while opposite results were obtained for negative values. By studying the effects of bubble size and their shape, the smaller bubbles provide a lower liquid velocity and a gas holdup. The effects of bubble‐induced turbulence and other non‐drag closure models such as turbulent dispersion and added mass forces were analysed. The gas velocity and gas holdup distributions, liquid velocity in the riser and downcomer, vectors of velocity magnitude and streamlines for liquid phase, the dynamics of gas holdup distribution and turbulent viscosity at different superficial gas velocities for different reactor configurations were computed. The effects of various geometrical parameters such as the draft tube clearance and the ratio of the riser to the downcomer cross‐sectional area on liquid velocities in the riser and the downcomer, the gas velocity and the gas holdup were explored. © 2011 Canadian Society for Chemical Engineering  相似文献   

5.
气升式内循环反应器的数值模拟和结构参数   总被引:1,自引:0,他引:1  
采用Euler-Euler双流体模型对内循环反应器(高1240 mm,直径165 mm,导流筒高590 mm)进行数值模拟,考察了表观气速、导流筒结构(导流筒内径比Dt/D,底隙高度)对反应器内上升区、下降区流体力学参数(气含率、液体速度)的影响. 结果显示,表观气速、导流筒内径、底隙高度对反应器气含率、液体速度有很大影响,随表观气速增加,反应器上升区、下降区气含率都增加,导流筒内径比为0.58时更易实现气液循环,底隙高度为30 mm时反应器内下降区气含率、气液速度都最小;气液分离器角度越大,进入下降区的气体越多,当气液分离器角度为45o时,能更好地实现气液循环.  相似文献   

6.
Computational Fluid Dynamics (CFD) is used to compare the hydrodynamics and mass transfer of an internal airlift reactor with that of a bubble column reactor, operating with an air/water system in the homogeneous bubble flow regime. The liquid circulation velocities are significantly higher in the airlift configuration than in bubble columns, leading to significantly lower gas holdups. Within the riser of the airlift, the gas and liquid phases are virtually in plug flow, whereas in bubble columns the gas and liquid phases follow parabolic velocity distributions. When compared at the same superficial gas velocity, the volumetric mass transfer coefficient, kLa, for an airlift is significantly lower than that for a bubble column. However, when the results are compared at the same values of gas holdup, the values of kLa are practically identical.  相似文献   

7.
The hydrodynamics and mass transfer in a large diameter bubble column (Dc 0.305 m), specifically, the effects of gas velocity and the presence of solids on the gas holdup structure, gas-liquid interfacial area, and volumetric mass transfer coefficients in viscous as well as low viscosity solutions are studied. The sulfite oxidation technique was employed to measure the gas-liquid interfacial area. Volumetric mass transfer coefficients were measured using a chemical method (sulfite oxidation) as well as physical absorption of oxygen from air, and the overall gas holdups were measured using the hydrostatic head technique. The effect of solids on the gas holdup structure was examined using the dynamic gas disengagement method. With the addition of polystyrene particles, the gas-liquid interfacial area decreased for low viscosity systems, whereas it increased for viscous systems. This was shown to be due to the effect of solids on bubble coalescence. The wettability characteristics of solid surfaces in the presence of different liquids have been suggested as the reason for the effect of solids on coalescence. Oil shale slurries presented a special case because of the mineral dissolution effect.  相似文献   

8.
Using a light transmission optical probe, the effect of superficial gas velocity on bubble properties(bubble size, bubble rising velocity, bubble frequency and local gas holdup) at axial and radial positions was determined in the riser and the downcomer of a concentric cylindrical airlift reactor. The vertical bubble length, the bubble rising velocity and the bubble frequency at axis in the riser increased with increasing superficial gas velocity and the bed height. The radial distribution of the local gas holdup, vertical bubble length and bubble frequency in the riser and the downcomer were found to be non-uniform. The profiles of the local gas holdup, vertical bubble length and bubble rising velocity in the riser were shown as parabolic shapes. The local gas holdup, the vertical bubble length and the bubble frequency in the downcomer changed with superficial gas velocity and the distance from the top of the draft tube.  相似文献   

9.
Two geometric configurations of gas-liquid separators were used in split-channel airlift reactors (0.1 m3 liquid volume; riser-to-downcomer cross-sectional area = 1.45; aspect ratio = 3.6) to test the effect of geometry on hydrodynamic performance and oxygen transfer behaviour. One of the configurations consisted of the basic internal-loop airlift head region without added features; the other had a 45° -inclined prism attached to the upper edge of the splitting baffle. For otherwise fixed conditions, the design of gas-liquid separators affected the induced liquid circulation velocity, the depth of penetration of the bubbles in the downcomer, the gas holdup in the downcomer and the mixing time. The overall volumetric gas-liquid oxygen transfer coefficient was not affected. The gas holdup in the riser was only marginally affected by the design of the separator; however, the relationship between the riser and the downcomer holdups was sensitive to separator configuration. Incorporation of the prism in the basic airlift configuration enhanced gas-liquid separation so much so that up to 30% reduction in the downcomer gas holdup could be obtained relative to the unmodified geometry. The impact of the separator designs on hydrodynamic behaviour could be explained as emanating from a combination of the gas-liquid separating ability of the design and its hydraulic resistance.  相似文献   

10.
The effects of the horizontal connection length (0.1 ± Le ± 0.5 m), the cross-sectional area ratio of downcomer-to-riser (0.11 ± Ad/Ar± 0.53), and the superficial gas velocity on gas phase holdups in the riser and downcomer were studied. The circulation liquid velocity, the mixing performance and the volumetric mass transfer coefficient in the external-loop airlift reactors were also measured. The horizontal connection length and Ad/Ar were major parameters which strongly affected the performance of external-loop airlift reactors. Useful correlations in the external-loop airlift reactors were obtained for gas holdups, the volumetric mass transfer coefficient, the circulation liquid velocity, and the mixing time.  相似文献   

11.
In an internal loop airlift reactor of 55L working volume,the gas-liquid volumetric oxygenmass transfer coefficient k_Lα,gas holdup ε_G and liquid circulation time t_c were measured with the sol-ution of carboxymethyl cellulose(CMC)to simulate the performance of a reactor with highly viscousbroth.Electric conductivity and oxygen probes were used to measure the local gas holdup,liquidcirculation time and oxygen mass transfer coefficient in the individual sections of the reactor(riser,downcomer and the gas-liquid separating section at the top of the reactor)and the total reactor,respectively.The values of k_Lα for the riser,downcomer and separation sections of the reactor were alsoestimated and compared with that for the total reactor.The results show that,both k_Lα and ε_G in-crease but t_c decreases with increasing gas velocity.Correlations and comparisons with works reportedin the literature are also presented.Data show that the methods developed for k_Lα measurements inthe individual section and  相似文献   

12.
在-气升式内环流反应器中试验考察了非牛顿流体羧甲基纤维素钠(CMC)中的气泡聚并现象以及表面活性物质对液相体积传质系数的影响。结果表明,非牛顿流体中气-液传质效率随黏度的增加而降低,其原因是黏度增加使Taylor泡的尾流趋于稳定,降低了液相扰动,气泡间易聚并,从而气-液传质效率低。向非牛顿流体中添加醇类物质会影响气-液传质行为,对于聚合物含量低的流体,添加微量醇可以促进气-液传质,聚合物含量高的非牛顿流体,微量醇的加入反而不利于气-液间传质过程。非牛顿流体在ILAR上升管中的气含率随着黏度的增加变化不大,而下降管中的气含率有所提高。  相似文献   

13.
Hydrodynamics and mass transfer characteristics of a three-phase airlift reactor were studied in a rectangular split-vessel reactor and using an air-seawater-marine sediment system. Experiments were conducted over a range of downcomer to riser cross-sectional area ratios (AD/AR = 0.65 to 1.0) for two-phase systems and for five sediment concentrations (5 to 25% w/v) using marine sediments. The influence of higher sediment concentrations (30 to 50% w/v) was examined for AD/AR = 1. The presence of fine sediment particles in the system had little effect on hydrodynamic and mass transfer parameters compared to the two-phase systems up to 25% loading, decreasing at higher loadings. The airlift reactor was found to meet the dissolved oxygen demand needed for a contaminated sediment treatment process. Axial distribution of the particles was uniform along the riser and the downcomer. Correlations were developed that described the hydrodynamic and mass transfer behaviour for all experimental conditions examined.  相似文献   

14.
Many experimental studies on the bubble column have been reported by Japanese researchers since around 1960. They include studies of bubble behaviour, bubble size distribution, transition from the homogeneous bubbly flow regime to the heterogeneous liquid circulation regime, liquid velocity distribution, longitudinal liquid mixing, hydrodynamic modelling, the gas holdup, and the volumetric coefficient of gas-liquid mass tranfer kLa. Studies covered various modified bubble columns, such as the airlift reactor with an external or internal loop, the packed bubble column, and others. Performance of three-phase bubble columns, which deal with suspensions or emulsions, and their use as bioreactors or chemical reactors were also studied.  相似文献   

15.
Extensive experimental studies on internal‐loop airlift reactors, including center‐rising (CR‐ALR) and annulus‐rising airlift reactors (AR‐ALR), have been reported in the literature. However, to the best of the authors’ knowledge, the effects of the aeration mode on the local hydrodynamics remain an under‐investigated area, especially for complex culture media. At present, it is difficult to select the best aeration mode for ALRs due to limited understanding of the pros and cons of the different modes. This study presents a detailed quantitative investigation of the overall gas holdup, local liquid velocity, liquid circulation time, shear rate distribution, and volumetric mass transfer coefficient in center‐ and annulus‐rising airlift bioreactors to better understand the effect of aeration mode on airlift bioreactor performance. Particle image velocimetry is employed to conduct local measurements. The results show that the overall gas holdup, liquid circulation time, and volumetric mass transfer coefficient are larger in the AR‐ALR than in the CR‐ALR. The local liquid velocity circulating into the downcomer of the AR‐ALR, which contributes to bubble entrainment and therefore to overall gas holdup, is higher than in the CR‐ALR. It was observed that a large circulation loop formed in the CR‐ALR, whereas two counter‐looping circulation cells appeared in the AR‐ALR. It was also found that the shear rate field was more uniform in the AR‐ALR than the CR‐ALR although the shear rates were similar in magnitude.  相似文献   

16.
The hydrodynamic and mass transfer characteristics of bubble and packed bubble columns with downcomer were investigated. The contactor consisted of two concentric columns of 0.11 and 0.2 m i.d., with the annulus acting as the downcomer. The packing used in this investigation was standard 16 mm stainless steel Pall rings. The superficial gas and liquid velocities, VG and VL, were varied from 0.01 to 0.09 and 1 × 10?3 to 8.8 × 10?3 m s?1 respectively. Two flow patterns, namely the bubble and pulse flows were observed in the packed bubble column with downcomer, as shown by a flow map. The liquid circulation velocity in both the contactors was observed to be constant throughout the ranges of VG and VL covered in this work. The effect of liquid viscosity (0.8 to 9.5 mPa ? s) and surface tension (45 to 72 mN m?1) on the flow pattern, liquid circulation, gas hold-up and pressure drop was investigated. The pressure drop characteristics across the two contactors have been compared with those across a bubble column. Values of the effective interfacial area, a, and the volumetric mass transfer coefficient, kL a, were measured by using chemical methods. Values of a as high as 180 and 700 m?1 and kL a as high as 0.075 and 0.22 s?1, in the bubble and packed bubble columns with downcomer, respectively, were obtained. The values of true liquid-side mass transfer coefficient, kL, were found to be independent of VG and were of the order of 5.5 × 10?4 and 3.5 × 10?4 m s?1, respectively, in the two contactors.  相似文献   

17.
Gas holdup, effective interfacial area and volumetric mass transfer coefficient were measured in two and three phase downflow bubble columns. The mass transfer data were obtained using the chemical method of sulfite oxidation, and the gas holdup was measured using the hydrostatic technique. Glass beads and Triton 114 were used to study the effects of solids and liquid surface tension on the gas holdup and the mass transfer parameters a and kL a . The gas holdup in three phase systems was measured for non-wettable (glass bead) and wettable (coal and shale particles) solids.

The mass transfer data obtained in the downflow bubble column were compared with the values published for upflow bubble columns. The results indicate that in the range of superficial gas velocities (0.002-0.025) m/s investigated, the values of the mass transfer coefficient were of the same order of magnitude as those observed in upflow systems, but the values of interfacial area were at least two fold greater. Also, the results showed that the operating variables and the physical properties had different influences on a and kL a in the downflow bubble column. Correlations for a and kL a for the downflow bubble column are proposed which predict the data with adequate accuracy in the range of operating conditions investigated.  相似文献   

18.
The effects of the horizontal connection length (0.1≤Lc≤0.5 m), the downcomer-to-riser cross-sectional area ratio (0.11≤Ad/Ar≤0.53) and the superficial gas velocity (0.02≤UG≤0.18 ms-1) on gas holdups in the riser and downcomer, the circulation liquid velocity, the mixing time, and the overall volumetric mass transfer coefficient were determined in external-loop airlift reactors without an extension tube above the downcomer [configuration (a)]. For otherwise fixed conditions, the absence of the extension tube strongly affected the hydrodynamic and mass transfer characteristics of external-loop airlift reactors. In contrast with the external-loop airlift reactor with the extension tube [configuration (b)], a large air pocket formed in the top horizontal connection and the surface aeration took place in the external-loop airlift reactor without the extension tube [configuration (a)]. As a result, the riser circulation liquid velocity in configuration (a) was slower than that in configuration (b). The riser and downcomer gas holdups, the mixing time and the overall volumetric mass transfer coefficient in configuration (a) were larger than those in configuration (b), respectively.  相似文献   

19.
The external loop airlift bubble column has been regarded as a promising type of gas-liquid or gas-liquid-solid biooreactor because of the liquid circulating flow between the riser and downcomer. A mini-scale column is useful and efficient in the process research and development for highly specialized materials such as fine chemicals, advanced bioproducts and biocatalysts utilized in two or three phase system. In this work, a mini-scale glass column of in volume was designed and characterized. The gas holdup εG in the riser was obtained by measuring the volume expansion through photographs taken with a digital camera. The liquid circulating velocity UL was measured by observing the time required for a tracer particle to travel a fixed distance in the downcomer through analysis of the images taken by a video camera. The gas-liquid volumetric oxygen transfer coefficient kLa and liquid-solid oxygen transfer coefficient kS were determined by our previous method in which the air oxidation of glucose was catalysed by the immobilized glucose oxidase gel beads suspended in the column to obtain a pseudo steady state concentration of the dissolved oxygen and the corresponding constant rate of glucose consumption. It was shown that even such a mini-scale external loop bubble column could be characterized in terms of gas holdup, liquid circulating velocity and mass transfer properties according to our previous correlations proposed for the bench to pilot scale column.  相似文献   

20.
Three geometric configurations of gas–liquid separators were used in split-channel airlift reactors (0·1 m3 liquid volume; riser-to-downcomer cross-sectional area ratio = 0·7; aspect ratio = 3.6) to test the effect of geometry on hydrodynamic performance and oxygen transfer behaviour. For otherwise fixed conditions, the design of gas–liquid separators affected the induced liquid circulation rate, the depth of penetration of the bubble layer in the downcomer, the gas holdup in the downcomer, the mixing time and the overall volumetric gas–liquid oxygen transfer coefficient. The gas holdup in the riser was only marginally affected by the design of the separator. The impact of the various separator designs on hydrodynamic behaviour could be explained as emanating from a combination of the gas–liquid separating ability of the design and its hydraulic resistance.  相似文献   