首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
This study presents theoretical investigation on the performance of air cycle refrigerator driving air conditioning system integrated desiccant system. Total system performance is evaluated and the system feasibility is examined. The system has such characteristics that (1) safe material of air and water are used as a refrigerant, (2) waste heat from air cycle refrigerator performs the regeneration of desiccant material for energy saving. It has been clarifying that (1) controlling the evaporative cooling process in air washer, the system can operate for a wide range of cooling loads, (2) the total coefficient of performance on air conditioning system is better than the conventional vapor compression system with reheating coil, and (3) the system performance highly depends on the ratio of the amount of outdoor intake air to the supply air.  相似文献   

2.
For providing good performance of dehumidifier and regenerator with certain dimensions, a new type of internally cooled/heated dehumidifier/regenerator based on the plate–fin heat exchanger (PFHE) was designed. To investigate the behavior of the new equipment, an experimental setup was established in an environment chamber with regulable temperature and humidity air. By the internally cooled dehumidification testing, effects of the cooling water temperature, the air flow rate and the desiccant temperature on the dehumidification performance and the cooling efficiency were presented. The behavior of internally cooled dehumidification process was compared with that of the adiabatic dehumidification process. The results suggested that the cooling efficiency decreased with the increasing of the cooling water temperature and desiccant with low temperature could bring more mass transfer coefficients. There is an optimal air flow rate to achieve the maximum absolute humidity decrease of the air. By the internally heated regeneration testing, effects of the air flow rate and the desiccant inlet temperature on the regeneration performance and air outlet parameters were discussed and also compared with those of the adiabatic regeneration process. It was concluded that the regeneration efficiency of internally heated regeneration was more than that of the adiabatic regeneration, and the internally heated regenerator could offer better thermal performance.  相似文献   

3.
The paper is aimed to develop a high performance rotary solid desiccant cooling system using a novel compound desiccant wheel (DW). The unique feature of the desiccant wheel is that it can work well under a lower regeneration temperature and have a higher dehumidification capacity due to the contribution of the new compound desiccant materials. Experimental results indicate that the novel desiccant wheel under practical operation can remove more moisture from the process air by about 20–40% over the desiccant wheel employing regular silica gel. A mathematical model that is used to predict the system performance has been validated with the test results. By integrating the desiccant wheel with evaporative cooling, heat recovery and heating for regeneration sections, a solid desiccant cooling system can be formed. Simulation results show that because of the use of the new compound desiccant, the desiccant cooling system can work under much lower regeneration temperature and have a relative high COP, thus low grade thermal energy resources, such as solar energy, waste heat, etc., can be efficiently utilized to drive such a cooling cycle.  相似文献   

4.
The paper presents a new desiccant cooling cycle to be integrated in residential mechanical ventilation systems. The process shifts the air treatment completely to the return air side, so that the supply air can be cooled by a heat exchanger. Purely sensible cooling is an essential requirement for residential buildings with no maintenance guarantee for supply air humidifiers. As the cooling power is generated on the exhaust air side, the dehumidification process needs to be highly efficient to provide low supply air temperatures. Solid rotating desiccant wheels have been experimentally compared with liquid sorption systems using contact matrix absorbers and cross flow heat exchangers. The best dehumidification performance at no temperature increase was obtained in an evaporatively cooled heat exchanger with sprayed lithium chloride solution. Up to 7 g kg−1 dehumidification could be reached in an isothermal process, although the surface wetting of the first prototype was low. The process then provides inlet air conditions below 20 °C for the summer design conditions of 32 °C, 40% relative humidity. With air volume flow rates of 200 m3 h−1 the system can provide 886 W of cooling power.A theoretical model for both the contact absorber and the cross flow system has been developed and validated against experimental data for a wide range of operating conditions. A simulation study identified the optimisation potential of the system, if for example the surface wetting of the liquid desiccant can be improved.  相似文献   

5.
Performance analysis of liquid desiccant dehumidification systems   总被引:5,自引:0,他引:5  
Desiccant systems find applications in a very large variety of industrial and daily usage products including the new HVAC installations. An overview of liquid desiccant technology has been presented in this paper along with a compilation of experimental performance data of liquid desiccant dehumidifiers, empirical dehumidification effectiveness and mass transfer correlations in a useful and easy to read tabular format. The latest trends in this area suggest that hybrid systems are of current interest to HVAC industry, not only for high latent load applications but also for improving indoor air quality. The paper presents a comprehensive comparative parametric analysis of packed bed dehumidifiers for three commonly used desiccant materials viz. triethylene glycol, lithium chloride and calcium chloride, using empirical correlations for dehumidification effectiveness from the literature. The analysis reveals significant variations and anomalies in trends between the predictions by various correlations for the same operating conditions, and highlights the need for benchmarking the performance of desiccant dehumidifiers.  相似文献   

6.
In this paper, high performance packing, namely, structured packing that has good heat and mass transfer characteristics, is proposed for dehumidification of air using liquid desiccants and for regeneration of liquid desiccants. In order to design a structured packing tower for liquid desiccant — air contacting operations, heat and mass transfer coefficients for each phase are required. This paper is concerned with the interface transfer of heat and mass when air is brought into contact with the liquid desiccant solution. A theoretical study of evaluating heat and mass coefficients in an air-desiccant contact system employing three liquid desiccants, namely calcium chloride, lithium chloride, and a mixture of 50% calcium chloride and 50% lithium chloride (called cost effective liquid desiccant, CELD) is investigated. Moreover, air phase transfer coefficients are correlated with flow rates of air and liquid and the temperature of air, whereas liquid phase coefficients are correlated with rates of air and liquid flow, and the temperature and concentration of the liquid. The findings for the three liquid desiccants are compared and discussed.  相似文献   

7.
An ejector expansion transcritical CO2 refrigeration cycle is proposed to improve the COP of the basic transcritical CO2 cycle by reducing the expansion process losses. A constant pressure mixing model for the ejector was established to perform the thermodynamic analysis of the ejector expansion transcritical CO2 cycle. The effect of the entrainment ratio and the pressure drop in the receiving section of the ejector on the relative performance of the ejector expansion transcritical CO2 cycle was investigated for typical air conditioning operation conditions. The effect of different operating conditions on the relative performance of the ejector expansion transcritical CO2 cycle was also investigated using assumed values for the entrainment ratio and pressure drop in the receiving section of the ejector. It was found that the COP of the ejector expansion transcritical CO2 cycle can be improved by more than 16% over the basic transcritical CO2 cycle for typical air conditioning operation conditions.  相似文献   

8.
The roto-cooler rotary blade air cycle air-conditioning system is simpler and less expensive than conventional vapour compression air-conditioning systems. This study analyses the effects of the unsteady flow on the heat exchanger and the performance of the roto-cooler system. The air properties, effects of the heat exchanger length on the air properties, the cooling capacity, the thermal coefficient of performance and the total coefficient of performance of the system are studied. Numerical results of the specific operating conditions are compared with the available data. The heat exchanger length of the prototype can be reduced significantly without loss of system performance.  相似文献   

9.
罗纪超 《制冷》2013,(3):7-10
提出了一种新型前置预冷转轮除湿复合空调系统,除湿转轮采用第Ⅲ类吸湿剂。对利用该系统用于独立新风系统的可行性进行了性能分析。结果表明,在华南地区夏季两种典型工况下,该转轮除湿采用再生温度为45℃就可以满足室内湿度的要求;对于相对湿度为90%且温度低于36.7℃的高温高湿工况,该转轮除湿采用再生温度为60℃仍可以满足室内湿度的要求;但与除湿转轮采用第Ⅰ类或第Ⅱ类吸湿剂相比,不能达到更低的送风露点温度。因此,该系统方案所需再生温度较低,较适用于高品质/舒适性空调方面。  相似文献   

10.
This paper describes a field experimental investigation of the effects of frost formation on the performance of a low-temperature large-scale evaporator coil used in industrial refrigeration systems. A series of experiments were conducted to determine the in situ coil cooling capacity of the evaporator over time as frost builds on its surfaces. Field-measured quantities include inlet and outlet air temperatures, inlet and outlet air relative humidity, and air volume flow rate. These measurements provide a baseline set of experimental data that can be used to validate numerical models of industrial evaporators operating under frosting conditions.  相似文献   

11.
Airside heat and mass transfer and fluid flow characteristics of a wavy-finned-tube direct expansion air coil under cooling and dehumidifying condition have been experimentally investigated. Experiments were carried out to study the effects of operating conditions such as: air temperature, air relative humidity, air face velocity, and evaporator pressure on the airside performance (cooling capacity, dehumidification capacity, pressure drop, and heat transfer coefficient) of the coil. Charts for coil wet conditions, partially wet or totally wet, were conducted to identify the coil wet conditions in terms of the operating conditions. Two techniques, enthalpy potential method and equivalent dry-bulb temperature method, were used to analyze the data and to deduce correlations for Colburn factors for the different coil wet conditions. Comparison between the correlations predictions of the two techniques was presented.  相似文献   

12.
The removal of moisture from the supply air using conventional air conditioners (A/C) represents a considerable portion of the air conditioning load in hot and humid regions. Desiccant assisted A/Cs are used to address this issue. In this work, the performance of a hybrid A/C, which consists of a desiccant wheel, an enthalpy wheel, and a vapor compression cycle (VCC), is investigated experimentally. The effect of the process air stream's temperature and humidity, and the effect of the ventilation rate on the hybrid A/C performance are investigated. The experimental results show that the hybrid A/C is more effective than the standalone VCC in maintaining the indoor conditions within the comfort zone. The simulation of the complete hybrid solar A/C that uses a concentrating photovoltaic/thermal collector shows that a system coefficient of performance higher than unity is possible.  相似文献   

13.
The thermal-hydraulic performance under conditions of an initial frost growth on the air-side surface, and for subsequent ‘refrosting’ after a defrost period is experimentally studied for folded-louvered-fin, microchannel heat exchangers. In total, five heat exchangers are considered; the thermal performances during one frost-growth cycle for four different fin geometries are compared in terms of overall heat transfer coefficient, pressure drop, and j and f factors; the defrost and refrost characteristics of two heat exchangers are compared to explore geometry effects. Typically, the performance under refrosting conditions becomes periodic and repeatable after the third or fourth refrosting cycle. The allowable frost growth period (before a defrost is required), the defrost requirement, and the thermal-hydraulic performance depend on heat exchanger geometry for the specimens used in this study.  相似文献   

14.
Evaporative cooling is used in industrial and air conditioning processes to reduce temperature in different fluids. Direct evaporation systems can lead to environmental problems such as Legionnaire's disease, and indirect systems reduce system efficiency.This work presents the manufacture, test bed set up and trials carried out on a ceramic evaporative cooling system which acts as a semi-indirect cooler. Depending on air characteristics, it may act as a sensible or enthalpic exchanger. The water cooled in a cooling tower, using the return air coming from the conditioned room (22 °C and 50% comfort conditions) goes through the ceramic pipes, exchanging sensible and latent heat with a current of outdoor air.The use of this recovery system is mainly in climates with a high temperature and humidity such as tropical environments where the system yields a decrease in supply air humidity, using the cooling power of return air.The tests presented show the system behaviour for various supply air conditions.  相似文献   

15.
The effect of air inlet humidity condition on the air-side heat transfer and pressure drop characteristics for an inclined brazed aluminum heat exchanger has been investigated experimentally. For a heat exchanger with a louver angle of 27°, fin pitch of 2.1 mm and flow depth of 27.9 mm, a series of tests are conducted for the air-side Reynolds numbers of 80–400, with variation of inlet humidity condition. The heat transfer data are obtained for wet condition only and the pressure drop data are measured for both dry and wet conditions. The inlet air temperature and relative humidity range are 12 °C and 60–90%, respectively. The inclination angles (θ) from the vertical position are 0, 14, 45, and 67° clockwise (leeward direction). The inclination angles affect moderately the sensible heat transfer coefficient for wet condition, and the pressure drops for both dry and wet conditions increase systematically with the inclination angle. The heat transfer and pressure drop characteristics under wet condition are not influenced substantially by the air inlet humidity for θ 45°. The effect of the louver directions at the inlet and outlet of the inclined heat exchanger on the performance is also addressed.  相似文献   

16.
The use of heat produced by solar thermal collectors is an interesting option for thermal driven air conditioning processes. A thermal driven cooling technique which fits well to non-tracking solar collectors is the desiccant cooling technique. Recently several projects have been carried out which focus on the connection of desiccant cooling systems with solar thermal energy for regeneration of the sorbents. This communication deals with three main topics: (1) experiences achieved in a realized system which is coupled to a solar collector are discussed, (2) a new concept is presented, in which a solar air collector is integrated into the desiccant cooling cycle as the only heat source and (3) a comparative study is presented which compares system performance for different system configurations and different climatic situations.  相似文献   

17.
Energy efficiency analysis of air cycle heat pump dryers   总被引:2,自引:0,他引:2  
In this paper, the feasibility of an air heat pump (reversed Brayton) cycle for tumbler clothes dryers is investigated. The goal is to increase the energy efficiency as compared to conventional electrically heated driers. Relatively simple models were used to compare the energy efficiency of the heat pump drier with that of a conventional air vented drier. The components were modeled using overall performance indices and thermodynamic relations. An air cycle heat pump dryer with practical components was found to be capable of significant efficiency improvements as compared with conventional dryers.  相似文献   

18.
In this study, an improved cooling cycle for a conventional multi-evaporators simple compression system utilizing ejector for vapour precompression is analyzed. The ejector-enhanced refrigeration cycle consists of multi-evaporators that operate at different pressure and temperature levels. A one-dimensional mathematical model of the ejector was developed using the equations governing the flow and thermodynamics based on the constant-area ejector flow model. The model includes effects of friction at the constant-area mixing chamber. The energy efficiency and the performance characteristics of the novel cycle are theoretically investigated. The comparison between the novel and conventional system was made under the same operating conditions. Also, a comparison of the system performances with environment friendly refrigerants (R290, R600a, R717, R134a, R152a, and R141b) is made. The theoretical results show that the COP of the novel cycle is better than the conventional system.  相似文献   

19.
This is the second paper of a series that assesses the performance of a refrigeration system model by means of cycle parameters. In this case, the condensation temperature is the parameter to study and it is focused on fin and tube condensers. It also studies the influence of the heat transfer models on the estimation of this refrigeration cycle parameter and different correlations for the heat transfer coefficients have been implemented in order to characterise the heat transfer in the heat exchangers. The flow inside the heat exchangers is considered one-dimensional as in previous works. In the cycle definition, other submodels for all the cycle component have been taken into account to complete the system of equations that characterises the behaviour of the refrigeration cycle. This global system is solved by means of a Newton–Raphson algorithm and a known technique called SEWTLE is used to model the heat exchangers. Some experimental results are employed to compare the condensation temperatures provided by the numerical procedure and to evaluate the performance of each heat transfer coefficient. These experimental results correspond to an air-to-water heat pump and are obtained by using R-22 and R-290 as refrigerants.  相似文献   

20.
Air conditioning is a non-critical application for fault detection and diagnosis (FDD) where decisions about servicing faults should involve the use of economics. Existing methods for evaluating impacts of faults on equipment performance only consider some individual factors such as the equipment coefficient of performance (COP) or cooling capacity. This paper develops an overall economic performance degradation index (EPDI) for air conditioning equipment that includes the combined effects of degradations in COP, cooling capacity, and sensible heat ratio (SHR). EPDI quantifies the performance degradation caused by faults based on economics so it can be used as part of the decision making process in an overall FDD system. Furthermore, EPDI can be used along with estimates of typical field performance degradations to assess the economic benefits associated with the application of automated FDD. A case study is presented where EPDI was applied to measurements for an existing unit where faults were artificially introduced.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号