首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 439 毫秒
1.
设计了一套复合式土壤源热泵性能实验台,采用冷却塔作辅助冷源、太阳能热水器作辅助热源,能够实现冬季供暖、夏季供冷、一年四季提供60~80℃生活热水的功能。给出了系统中热泵机组、空调末端设备、冷却塔、水泵、太阳能热水器等主要部件的选型计算方法,经搭建好的土壤源热泵性能实验台运行测试,制冷和制热效果良好,同时也解决了土壤热平衡问题。  相似文献   

2.
A solar-powered adsorption chiller with heat and mass recovery cycle was designed and constructed. It consists of a solar water heating unit, a silica gel-water adsorption chiller, a cooling tower and a fan coil unit. The adsorption chiller includes two identical adsorption units and a second stage evaporator with methanol working fluid. The effects of operation parameter on system performance were tested successfully. Test results indicated that the COP (coefficient of performance) and cooling power of the solar-powered adsorption chiller could be improved greatly by optimizing the key operation parameters, such as solar hot water temperature, heating/cooling time, mass recovery time, and chilled water temperature. Under the climatic conditions of daily solar radiation being about 16–21 MJ/m2, this solar-powered adsorption chiller can produce a cooling capacity about 66–90 W per m2 collector area, its daily solar cooling COP is about 0.1–0.13.  相似文献   

3.
A prototype low capacity (10 kW) single stage Li–Br absorption heat pump (AHP), suitable for residential and small building applications has been developed as a collaborative result between various European research institutes and industries. The primary heat source for the AHP is supplied from flat plate solar collectors and the hot/chilled water from the unit is delivered to a floor heating/cooling system. In this paper we present the simulation results and an overview of the performance assessment of the complete system. The calculations were performed for two building types (high and low thermal mass), three climatic conditions, with different types of solar collectors and hot water storage tank sizes and different control systems for the operation of the installation. The simulations were performed using the thermal simulation code TRNSYS. The estimated energy savings against a conventional cooling system using a compression type heat pump was found to be in the range of 20–27%.  相似文献   

4.
A method of improving the performance of heat pumps for domestic space heating has been investigated. The study focuses on the short-term storage of heat pump output energy in concrete floor panels. This paper describes the dynamic computer simulation of an air to water heat pump, a floor panel energy store and energy flowpaths in a dwelling. The heating plant, controls and building thermal behaviour, were simulated as a complete energy system to enable the study of interactions between the subsystems. The model heating system comprised a number of under floor water heated panels installed in ground floor rooms of a two storey dwelling. Supplementary energy was supplied by direct electric heaters situated in most rooms. Heat pump operating periods were controlled as a function of the external air temperature within two prescribed occupancy intervals per day. Results of the investigation indicate that a heat pump system using floor panel storage and emission may be efficiently managed to provide nearly continuous heating with little supplementary energy input. The short-term storage of energy in thick floor panels allowed the heat pump to be operated for extended periods without cycling. Because of this, the seasonal loss in heat pump performance resulting from intermittent operation was less than 1 per cent. Attempting to supply the total space heating load with the heat pump and floor panel system resulted in severe overheating during periods of high solar or casual gain. Under these conditions the simple control strategy based on the measurement of external air temperature was ineffective. This problem was eliminated by reducing the heat pump energy input to the dwelling and supplying about 10 per cent of the seasonal energy demand by direct electric heaters. The influence of floor panel energy storage capacity on the performance of the heating system was investigated. Concrete panel depths of between 25 and 150 mm were considered. The seasonal system efficiency was found to increase with floor panel thickness, although not significantly with panel depths beyond 100 mm. The extensive use of floor slabs to store energy caused mean floor temperatures to be higher than when using direct electric air heaters only. However, with the depth of under floor insulation considered in the study (75 mm), heating the floor slab increased the seasonal energy loss of the building by only 4 per cent.  相似文献   

5.
Performance of combined solar-heat pump systems   总被引:1,自引:0,他引:1  
A comparative study of the performance of combined solar heat pump systems for residential space and domestic hot water heating has been undertaken. Simulations have been made with TRNSYS[1] of three basic combined configurations, as well as conventional solar and conventional heat pump systems, in two different climates, Madison, Wisconsin, and Albuquerque, New Mexico.The three combined systems are the series system in which the solar storage is used as the source for the heat pump, the parallel system in which ambient air is used as the source for the heat pump, and the dual source system in which the storage or ambient is used as the source depending on which source yields the lowest work input. The influence of collector area, number of glazings, main storage volume to collector area ratio, and heat pump coefficient of performance were determined.The results indicate that the parallel combined system is probably the most practical solar-heat pump configuration. The thermal performance at a given collector area is consistently superior to both the series or the dual source systems over the heating season. Costs and the extent to which summer cooling is a requirement determine the relative merit of the conventional heat pump, conventional heat pump, conventional solar, and parallel systems.  相似文献   

6.
An absorption system can be used for space cooling as well as for space heating. This dual purpose may be achieved by using the system as heat pump in wintertime. Absorption heat pump heating may be an interesting alternative, particularly for countries where there is a shortage of electric power.When an absorption unit is used as heat pump, its mode of operation is not modified: the internal temperatures of the cycle are only raised. Commercially available LiBr units were tested as heat pumps. COP and heating capacity were considered as a function of cold source temperature for different temperatures of the useful heat. The COP arrived at 1.7, which must be considered a high value for a thermally driven heat pump.Simulations were carried out in order to compare the performance of “conventional” solar, solar assisted heat pump and the combined series system under two different climate conditions. The series system showed performance 25–75 per cent better than “conventional” solar alone.  相似文献   

7.
The NSF/CSU Solar House I solar heating and cooling system became operational on 1 July 1974. During the first months of operation the emphasis was placed on adjustment, “tuning”, and fault correction in the solar collection and the solar/fuel/cooling subsystems. Following this initial check out period, analysis and testing of the system utilizing a full year of data was begun. This paper discusses the preliminary performance of the heating and cooling system.

During the period 1 August 1974–31 January 1975, approximately 40 per cent of the cooling load was provided by solar energy. Solar heating over the same period of time provided 86 per cent of the space heating load and 68 per cent of the domestic hot water heating load. These percentages represent a total solar contribution of 33,996 MJ delivered to load (8061 MJ to the cooling unit; 20,687 MJ to heating; 5248 MJ to hot water). Natural gas accounted for 22,442 MJ, total. In addition, preliminary analysis has provided several significant results associated with the operating characteristics of the solar system and the individual components.  相似文献   


8.
太阳能吸收式空调及供热系统的设计和性能   总被引:48,自引:6,他引:42  
一套太阳能吸收式空调及供热综合系统已在山东省乳山市建成。该系统由热管式真空管集热器、溴化锂吸收式制冷机、储水箱、循环、冷却塔、空调箱、辅助燃油锅炉和自动控制系统等内部分组成,具有夏季制冷、冬季供热和全年提供生活用热水等功能。太阳能集热器总采光面积540m∧2,制冷、供热功率100kW,空调、采暖建筑面积1000m∧2供生活用热水量32m∧3/d。文中着重介绍了系统的设计特点和测试性能。  相似文献   

9.
A solar thermal cooling and heating system at Carnegie Mellon University was studied through its design, installation, modeling, and evaluation to deal with the question of how solar energy might most effectively be used in supplying energy for the operation of a building. This solar cooling and heating system incorporates 52 m2 of linear parabolic trough solar collectors; a 16 kW double effect, water-lithium bromide (LiBr) absorption chiller, and a heat recovery heat exchanger with their circulation pumps and control valves. It generates chilled and heated water, dependent on the season, for space cooling and heating. This system is the smallest high temperature solar cooling system in the world. Till now, only this system of the kind has been successfully operated for more than one year. Performance of the system has been tested and the measured data were used to verify system performance models developed in the TRaNsient SYstem Simulation program (TRNSYS). On the basis of the installed solar system, base case performance models were programmed; and then they were modified and extended to investigate measures for improving system performance. The measures included changes in the area and orientation of the solar collectors, the inclusion of thermal storage in the system, changes in the pipe diameter and length, and various system operational control strategies. It was found that this solar thermal system could potentially supply 39% of cooling and 20% of heating energy for this building space in Pittsburgh, PA, if it included a properly sized storage tank and short, low diameter connecting pipes. Guidelines for the design and operation of an efficient and effective solar cooling and heating system for a given building space have been provided.  相似文献   

10.
Aquifers are underground porous formations containing water. Confined aquifers are the formations surrounded by two impermeable layers, called cap rocks and bed rocks. These aquifers are suitable for seasonal thermal energy storage.In the present study, a confined aquifer was considered to meet the cooling and heating energy needs of a residential complex located in Tehran, Iran. Three different alternatives were analyzed in this aquifer thermal energy storage (ATES), including: using ATES for cooling alone, for cooling and heating, as a heat pump, and for heating alone, employing flat plate solar energy collectors. A numerical simulation, based on the finite difference method, was carried out for velocity and temperature distributions as well as the heat transfer in the aquifer. The thermal energy recovery factor and the annual coefficient of performance of the system were determined under various schemes of operation, revealing that the combination of the ATES with the heat pump, to meet both cooling and heating needs of the complex, is the best. The study was repeated for different aquifer properties.  相似文献   

11.
A novel solar-powered adsorption cooling system for low-temperature grain storage has been built, which consists of a solar-powered water heating system, a silica gel–water adsorption chiller, a cooling tower and a fan coil unit. The adsorption chiller is composed of two identical adsorption units, each of them containing an adsorber, a condenser, and an evaporator/receiver. The two water evaporators have been incorporated into one methanol evaporator by the use of the concept of a gravity heat pipe. In order to improve the system efficiency and achieve continuous cooling production, the adsorbers are operated out-of-phase, and heat and mass recovery processes have been used. During the period from July to September of 2004, the system was put into experimental operation to cool the headspace (i.e., the air volume above the grain) of a grain bin. Three months of operation showed promising performance. The chiller had a cooling power between 66 and 90 W per m2 of collector surface, with a daily solar cooling coefficient of performance (COPsolar) ranging from 0.096 to 0.13. The electric cooling COP was between 2.6 and 3.4.  相似文献   

12.
《Applied Thermal Engineering》2007,27(8-9):1612-1628
The design and performance of a solar (and/or natural gas) powered adsorption (desiccant-vapor) heat pump for residential cooling (and heating) is described. The entire system is modeled and analyzed: adsorption heat pump itself, ice thermal storage reservoir, and solar collectors. The adsorption heat pump embodies patent pending improvements to the state-of-the-art which elevate coefficient of performance for cooling from a maximum of 1.2 reported in the literature to a conservatively predicted minimum of 1.5. The adsorption device utilizes economical, robust configurations (shell-and-tube) and components (helical annular finned tubes, multi-lumen tubes) commonly employed in heat exchangers in a manner heretofore untried, as well as other enhancements (metal wool to diffuse heat throughout the adsorbent). The vessel is all aluminum and the adsorbent-refrigerant pair is carbon-ammonia. The ice reservoir provides 24 h cooling. Two types of solar collector are determined to be satisfactory at the selected operating temperature of 170 °C: (1) compound parabolic concentrator with high concentration ratio (10+) and automatic tilt adjustment, and (2) evacuated (0.001 atm) flat panel, similar to atmospheric pressure versions employed for domestic water heating.  相似文献   

13.
S. Sillman 《Solar Energy》1981,27(6):513-528
Annual storage is used with active solar heating systems to permit storage of summer-time solar heat for winter use. This paper presents the results of a comprehensive computer simulation study of the performance of active solar heating systems with long-term hot water storage. A unique feature of this study is the investigation of systems used to supply backup heat to passive solar and energy-conserving buildings, as well as to meet standard heating and hot water loads.

Findings show that system performance increases linearly as storage volume increases, up to the point where the storage tank is large enough to store all heat collected in summer. This point, the point of “unconstrained operation”, is the likely economic optimum. In contrast to diurnal storage systems, systems with annual storage show only slightly diminishing returns as system size increases. Annual storage systems providing nearly 100% solar space heat may cost the same or less per unit heat delivered as a 50 per cent diurnal solar system. Also in contrast to diurnal systems, annual storage systems perform efficiently in meeting the load of a passive or energy-efficient building. A breakeven cost 4¢–10¢/kWh is estimated for optimal 100 per cent solar heating in the U.S.A.  相似文献   


14.
Providing the heating system with coal in greenhouses causes harmful results in terms of carbon emissions. In this study, analyzes were performed to meet the electrical energy required for the heating system with a heat pump from a solar photovoltaic-hydrogen system. For floor area 25000 m2 where greenhouses the required energy is obtained directly from hydrogen without using a heat pump 3000 m2 solar panel area required. The use of a heat pump reduces energy needs but it is also not feasible for large greenhouses. For convenience, a solar photovoltaic-hydrogen-heat pump system analysis was also made for 1000 m2 floor area greenhouses and it is found that the 24 m2 solar panel area is adequate in terms of meeting energy demand. Using a solar-hydrogen-heat pump system reduces carbon emissions by 86.5 tons per 1000 m2 floor area greenhouse. Considering the hydrogen storage system becomes unfeasible. We normalized the greenhouse floor area to 1 m2 and proposed reference values for hydrogen to be produced in 1 h, storage, and PV area. In addition, an analysis was made for the use of hydrogen energy for greenhouses that do not require a heating system and only work with a water pump.  相似文献   

15.
Abstract

In this paper, a parametric analysis of two solar heating and cooling systems, one using an absorption heat pump and the other one using an adsorption heat pump, was performed. The systems under investigation were designed to satisfy the energy requirements of a residential building for space heating/cooling purposes and domestic hot water production. The system with the absorption heat pump was analyzed upon varying (i) the solar collectors’ area, (ii) the volume of the hot water storage, (iii) the volume of the cold water tank, and (iv) the climatic conditions. The system with the adsorption heat pump was evaluated upon varying (i) the inlet temperature of hot water supplied to the adsorption heat pump, (ii) the volume of the hot water storage, (iii) the volume of the cold water tank, and (iv) the climatic conditions. The analyses were performed using the dynamic simulation software TRNSYS in terms of primary energy consumption, global carbon dioxide equivalent emissions, and operating costs. The performance of the solar heating and cooling systems was compared with those associated with a conventional system from energy, environmental and economic points of views in order to evaluate the potential benefits.  相似文献   

16.
The performance of photovoltaic/thermal (PV/T) solar collector had been studied theoretically and experimentally for some years. Air and water streams were used as the heat carriers for space heating or services hot water systems. The cooling effect allows the PV module to work at lower temperature and its PV efficiency is therefore improved. However, such an advantage diminishes when the solar irradiance is high. To improve the situation a new type of PV/T collector is proposed. It works as the evaporator of a heat pump, in that refrigerant evaporates in the tubing at the back of the flat-plate collector and the PV module is adhered to the front surface. Mathematical models were developed to simulate the complex energy conversion processes. Numerical analysis was then performed based on the distributed parameters approach. An experimental rig was also built to test its real performance. Our results showed that the PV/T evaporator had an overall efficiency in the range of 0.64–0.87, thermal efficiency 0.53–0.64 and PV efficiency 0.124–0.135. The simulation results were found in good agreement with the experiment measurements. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

17.
为解决太阳电池的发电效率随温度升高而下降以及地源热泵系统供热引起的土壤热失衡问题,以典型居住建筑的光伏/光热-地源热泵(PV/T-GSHP)联合供热系统为研究对象,基于TRNSYS软件,采用土壤温度、地源热泵机组季节能效比、光伏发电效率和太阳能保证率为评价指标,对该联合供热系统进行运行性能分析。研究结果表明:夏热冬冷地区(以长沙为例)太阳能保证率相对较高,PV/T组件面积为满屋顶最大化安装(900 m2)时,第20年末土壤温度相比初始地温仅升高0.8 ℃,热泵机组季节能效比约为5.1,太阳能保证率为97.0%~98.7%;不同气候地区的太阳能保证率与PV/T组件面积和建筑全年累计供热量有关,通过定义单位建筑全年累计供热量PV/T组件面积指标,得到中国不同气候地区的太阳能保证率与该指标的耦合关系,回归方程的决定系数R2为0.983,得出在已知建筑全年累计供热量和太阳保证率设计目标值的条件下所需PV/T组件面积的计算方法。PV/T-GSHP联合供热系统的全年运行能耗显著小于平板太阳能集热器-地源热泵联合系统(最小降幅为沈阳,49.7%),远小于空气源热泵(最小降幅为石家庄,79.8%)和燃气壁挂炉(最小降幅为沈阳,65.1%)。  相似文献   

18.
太阳能跨季节储热供热系统试验分析   总被引:3,自引:0,他引:3  
介绍了一种太阳能-土壤源热泵联合供热系统,对其运行试验数据进行了分析,并对其运行能效比与两种单独由土壤源热泵供热的模式进行了比较。土壤温度的变化不仅与取热速率有关,还与地温的自动恢复能力相关。该试验建筑所在的土壤条件下地温的恢复能力为30~40MJ/d。采用太阳能-土壤源热泵联合系统能效比最高,土壤源热泵单机组双供系统次之,而土壤源热泵单机组单供系统能效比最低。太阳能跨季节储热及土壤源热泵联合供热系统适用于热负荷远大于冷负荷的建筑。  相似文献   

19.
如何保证地源热泵式沼气池加温系统长期稳定运行   总被引:1,自引:1,他引:0  
针对地源热泵式沼气池加温系统中出现的冬夏季取排热不平衡从而影响其长期稳定运行的问题,本文在采取控制运行方式、增加辅助热源和蓄热系统解决方法的分析基础上,从充分利用可再生能源和地源热泵设备的角度出发,提出热泵供热和制冷互补模式与太阳能-地源热泵多功能互补模式,并对其可行性进行分析。  相似文献   

20.
A thermodynamic analysis has shown that inorganic salt hydrates are attractive candidates for absorbents in heat pump cycles. Their computed performance efficiencies compare favorably to those of previously proposed solid and liquid absorbents, under conditions typical of domestic, solar-powered, intermittent operation. It was found that hydrate cooling cycles, with coefficients-of-performance in the range of 0.6-0.7, can significantly outperform all others considered. In space heating applications, solid-absorbent cycles were far superior to a typical liquid-absorbent cycle in both overall efficiency and per cent of thermal energy input stored. Predicted hydrate coefficients-of-performance were in the range 1.4-1.6 with 75–85 per cent effective storage.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号