首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
《Clinical neurophysiology》2020,131(9):2216-2223
ObjectiveTo study if comatose cardiac arrest patients can be assessed with a reduced number of EEG electrodes.Methods110 routine EEGs from 67 consecutive patients, including both hypothermic and normothermic EEGs were retrospectively assessed by three blinded EEG-experts using two different electrode montages. A standard 19-electrode-montage was compared to the reduced version of the same EEGs, down-sampled to six electrodes (F3, T3, P3, F4, T4, P4). We used intra-rater and inter-observer statistics to assess the reliability of the reduced montage for background features and discharges.ResultsThe reduced montage had almost perfect performance for background continuity (κ 0.80–0.88), including identification of highly malignant backgrounds (burst-suppression/suppression) (κ 0.85–0.94) and benign backgrounds (continuous/nearly continuous) (κ 0.85–0.91). We found substantial performance for identifying rhythmic/periodic discharges (κ 0.79–0.86). The reduced montage had high accuracy for assessment of both highly malignant (sensitivity 91–95%, specificity 94–99%) and benign (sensitivity 89–98%, specificity 91–96%) backgrounds, and periodic/rhythmic patterns (sensitivity 79–100%, specificity 89–99%), compared to the full montage. The inter-observer variability was not increased by the reduced montage.ConclusionReduced EEG had high performance for classifying important background and discharge patterns in this post cardiac arrest cohort.SignificanceOur results support the use of reduced EEG-montage for monitoring comatose cardiac arrest patients.  相似文献   

2.
《Clinical neurophysiology》2020,131(12):2781-2792
ObjectiveTo determine the optimal depth electrode montages for the assessment of effective connectivity based on single-pulse electrical stimulation (SPES). To determine the effect of SPES locations on the extent of resulting neuronal propagations.MethodsWe studied 14 epilepsy patients who underwent invasive monitoring with depth electrodes and measurement of cortico-cortical evoked potentials (CCEPs) and cortico-cortical spectral responses (CCSRs). We determined the effects of electrode montage and stimulus sites on the CCEP/CCSR amplitudes.ResultsBipolar and Laplacian montages effectively reduced the degree of SPES-related signal deflections at extra-cortical levels, including outside the brain, while maintaining those at the cortical level. SPES of structures more proximal to the deep white matter, compared to the cortical surface, elicited greater CCEPs and CCSRs.ConclusionsOn depth electrode recording, bipolar and Laplacian montages are suitable for measurement of near-field CCEPs and CCSRs. SPES of the white matter axons may induce neuronal propagations to extensive regions of the cerebral cortex.SignificanceThis study helps to establish the practical guidelines on the diagnostic use of CCEPs/CCSRs.  相似文献   

3.
4.
《Brain stimulation》2020,13(3):815-818
BackgroundRecording electroencephalography (EEG) from the targeted cortex immediately before and after focal transcranial electrical stimulation (TES) remains a challenge.MethodsWe introduce a hybrid stimulation-recording approach where a single EEG electrode is inserted into the inner electrode of a double-ring montage for focal TES. The new combined electrode was placed at the C3 position of the EEG 10–20 system. Neuronal activity was recorded in two volunteers before and after 20 Hz alternating-current TES at peak-to-peak intensities of 1 and 2 mA. TES-induced electric field distributions were simulated with SIMNIBS software.ResultsUsing the hybrid stimulation-recording set-up, EEG activity was successfully recorded directly before and after TES. Simulations revealed comparable electrical fields in the stimulated cortex for the pseudomonopolar montage with and without embedded EEG electrode.ConclusionThe hybrid TES-EEG approach can be used to probe after-effects of focal TES on neuronal activity in the targeted cortex.  相似文献   

5.
《Brain stimulation》2019,12(5):1177-1186
BackgroundCerebellar transcranial direct current stimulation (ctDCS) is increasingly used to modulate cerebellar excitability and plasticity in healthy subjects and various patient populations. ctDCS parameters are poorly standardized, and its physiology remains little understood. Our aim was to compare the physiological effects of three different non-target electrode positions (buccinator muscle, supraorbital region, deltoid muscle).MethodsIn the first experiment, physiological after-effects of ctDCS were compared based on cerebellar-brain inhibition (CBI) in a group of 15 healthy right-handed participants. In the second experiment, CBI after-effects of ctDCS were assessed using different transcranial magnetic stimulation (TMS) intensities in 14 participants (CBI recruitment curve). The electric field distribution was calculated for each of the electrode montages based on a single anatomically accurate head model.ResultsAnodal and cathodal ctDCS polarities significantly decreased cerebellar-brain inhibition (CBI) with no substantial differences between the montages. Lower cerebellar TMS intensities resulted in decreased CBI following cathodal and increased CBI after anodal ctDCS. Computational modeling revealed minor differences in the electric field distribution between non-target electrode positions based on the effect size.ConclusionOur results show that the non-target electrode position has no significant impact on modeling results and physiological ctDCS after-effects. The recruitment of the cerebellar-M1 connection, however, varied depending on ctDCS polarity and cerebellar transcranial magnetic stimulation intensity, possibly due to diverse effects on different cell populations in the cerebellar cortex. This may be one of the reasons why ctDCS effects on functional measures are difficult to predict.  相似文献   

6.
《Brain stimulation》2020,13(5):1245-1253
BackgroundExternal trigeminal nerve stimulation (ETNS) is an emergent, non-invasive neurostimulation therapy delivered bilaterally with adhesive skin electrodes. In previous studies, ETNS was associated to a decrease in seizure frequency in patients with focal drug-resistant epilepsy (DRE).ObjectiveTo determine the long-term efficacy and tolerability of ETNS in patients with focal DRE. Moreover, to explore whether its efficacy depends on the epileptogenic zone (frontal or temporal), and its impact on mood, cognitive function, quality of life, and trigeminal nerve excitability.MethodsForty consecutive patients with frontal or temporal DRE, unsuitable for surgery, were randomized to ETNS or usual medical treatment. Participants were evaluated at 3, 6 and 12 months for efficacy, side effects, mood scales, neuropsychological tests and trigeminal nerve excitability.ResultsSubjects had a median of 15 seizures per month and had tried a median of 12.5 antiepileptic drugs. At 12 months, percentage of responders was 50% in ETNS group and 0% in control group. Seizure frequency in ETNS group decreased by −43.5% from baseline. Temporal epilepsy subgroup responded better than frontal epilepsy subgroup (55.56% vs. 45.45%, respectively). Median stimulation intensity was 6.2 mA. ETNS improved quality of life, but not anxiety or depression. Long-term ETNS affected neither neuropsychological function, nor trigeminal nerve excitability. No relevant adverse events were observed.ConclusionsETNS is an effective and well-tolerated therapy for focal DRE. Patients with temporal epilepsy showed a better response than those with frontal epilepsy. Future studies with larger populations may define its role compared to other neurostimulation techniques.Classification of evidenceThis study provides Class II evidence that ETNS reduces seizure frequency in patients with focal DRE.  相似文献   

7.
《Clinical neurophysiology》2019,130(3):352-358
ObjectiveTo accurately deliver a source-estimated neurofeedback (NF) signal developed on a 128-sensors EEG system on a reduced 32-sensors EEG system.MethodsA linearly constrained minimum variance beamformer algorithm was used to select the 64 sensors which contributed most highly to the source signal. Monte Carlo-based sampling was then used to randomly generate a large set of reduced 32-sensors montages from the 64 beamformer-selected sensors. The reduced montages were then tested for their ability to reproduce the 128-sensors NF. The high-performing montages were then pooled and analyzed by a k-means clustering machine learning algorithm to produce an optimized reduced 32-sensors montage.ResultsNearly 4500 high-performing montages were discovered from the Monte Carlo sampling. After statistically analyzing this pool of high performing montages, a set of refined 32-sensors montages was generated that could reproduce the 128-sensors NF with greater than 80% accuracy for 72% of the test population.ConclusionOur Monte Carlo reduction method was used to create reliable reduced-sensors montages which could be used to deliver accurate NF in clinical settings.SignificanceA translational pathway is now available by which high-density EEG-based NF measures can be delivered using clinically accessible low-density EEG systems.  相似文献   

8.
《Brain stimulation》2021,14(4):761-770
BackgroundObsessive-compulsive disorder (OCD) has consistently been linked to abnormal frontostriatal activity. The electrophysiological disruption in this circuit, however, remains to be characterized.Objective/hypothesisThe primary goal of this study was to investigate the neuronal synchronization in OCD patients. We predicted aberrant oscillatory activity in frontal regions compared to healthy control subjects, which would be alleviated by deep brain stimulation (DBS) of the nucleus accumbens (NAc).MethodsWe compared scalp EEG recordings from nine patients with OCD treated with NAc-DBS with recordings from healthy controls, matched for age and gender. Within the patient group, EEG activity was compared with DBS turned off vs. stimulation at typical clinical settings (3.5 V, frequency of stimulation 130 Hz, pulse width 60 μs). In addition, intracranial EEG was recorded directly from depth macroelectrodes in the NAc in four OCD patients.ResultsCross-frequency coupling between the phase of alpha/low beta oscillations and amplitude of high gamma was significantly increased over midline frontal and parietal electrodes in patients when stimulation was turned off, compared to controls. Critically, in patients, beta (16–25 Hz) -gamma (110–166 Hz) phase amplitude coupling source localized to the ventromedial prefrontal cortex, and was reduced when NAc-DBS was active. In contrast, intracranial EEG recordings showed no beta-gamma phase amplitude coupling. The contribution of non-sinusoidal beta waveforms to this coupling are reported.ConclusionWe reveal an increased beta-gamma phase amplitude coupling in fronto-central scalp sensors in patients suffering from OCD, compared to healthy controls, which may derive from ventromedial prefrontal regions implicated in OCD and is normalized by DBS of the nucleus accumbens. This aberrant cross-frequency coupling could represent a biomarker of OCD, as well as a target for novel therapeutic approaches.  相似文献   

9.
《Clinical neurophysiology》2021,132(7):1444-1451
ObjectiveTo evaluate the safety and temporal dynamic of the antiepileptic effect of spaced transcranial direct current stimulation (tDCS) in different focal epilepsies.MethodsCathodal tDCS with individual electrode placement was performed in 15 adults with drug resistant focal epilepsy. An amplitude of 2 mA was applied twice for 9 minutes, with an interstimulation interval of 20 minutes. Tolerability was assessed via the Comfort Rating Questionnaire and the frequency of interictal epileptiform discharges (IEDs) was sequentially compared between the 24 hours before and after tDCS.ResultsTDCS led to a significant reduction in the total number of IEDs/24 h by up to 68% (mean ± SD: −30.4 ± 21.1%, p = 0.001) as well as in seizure frequency (p = 0.041). The maximum IED reduction was observed between the 3rd and 21st hour after stimulation. Favorable clinical response was associated with structural etiology and clearly circumscribed epileptogenic foci but did not differ between frontal and temporal epilepsies. Overall, the tDCS treatment was well tolerated and did not lead to severe adverse events.ConclusionsThe spaced stimulation approach proved to be safe and well-tolerated in patients with drug-resistant unifocal epilepsies, leading to sustained IED and seizure frequency reduction.SignificanceSpaced tDCS induces mediate antiepileptic effects with promising therapeutic potential.  相似文献   

10.
《Clinical neurophysiology》2021,132(10):2702-2710
ObjectiveHigh-frequency repetitive transcranial magnetic stimulation (rTMS) has been shown to reduce neuropathic pain, but intermittent “theta-burst” stimulation (iTBS) could be a better alternative because of shorter duration and greater ability to induce cortical plasticity. Here we compared head-to-head the pain-relieving efficacy of the two modalities when applied daily for 5 days to patients with neuropathic pain.MethodsForty-six patients received 20 Hz-rTMS and/or iTBS protocols and 39 of them underwent the full two procedures in a random cross-over design. They rated pain intensity, sleep quality, fatigue and general health status daily during 5 consecutive weeks.ResultsPain relief during the month following stimulation was superior after 20 Hz-rTMS relative to iTBS (F(1,38) = 4.645; p = 0.037). Correlation between respective levels of maximal relief showed a significant deviation toward the 20 Hz-rTMS effect. A greater proportion of individuals responded to 20 Hz-rTMS (52% vs 32%, 95 %CI[0.095–3.27]; p = 0.06), and reports of fatigue significantly improved after 20 Hz-rTMS relative to iTBS (p = 0.01). General health and sleep quality scores did not differentiate both techniques.ConclusionsHigh-frequency rTMS appeared superior to iTBS for neuropathic pain relief.SignificanceAdequate matching between the oscillatory activity of motor cortex and that of rTMS may increase synaptic efficacy, thus enhancing functional connectivity of motor cortex with distant structures involved in pain regulation.  相似文献   

11.
《Clinical neurophysiology》2021,132(6):1221-1225
ObjectiveTo analyze and identify differences in sleep spindles in children with restless sleep disorder (RSD), restless legs syndrome (RLS) and normal controls.MethodsPSG (polysomnography) from children with RSD, RLS and normal controls were analyzed. Sleep spindle activity was detected on one frontal and one central electrode, for each epoch of N2 and N3 sleep. Sleep spindle density, duration and intensity (density × duration) were then obtained and used for analysis.ResultsThirty-eight children with RSD, twenty-three children with RLS and twenty-nine controls were included. The duration of frontal spindles in sleep stage N2 was longer in children with RSD than in controls. Frontal spindle density and intensity tended to be increased in RSD children. No significant differences were found for central spindles.ConclusionChildren with RSD had longer frontal spindles. This finding may contribute to explain the occurrence of excessive movement activity during sleep and the presence of daytime symptoms.SignificanceRecent research has demonstrated that children with RSD have increased NREM instability and sympathetic activation during sleep. Analyzing sleep spindles in children with RSD in comparison with children with RLS and controls adds to our understanding of the pathophysiology or RSD and its effects on daytime impairment.  相似文献   

12.
《Clinical neurophysiology》2020,131(10):2460-2468
ObjectiveTo establish a method for magnetospinography (MSG) measurement after ulnar nerve stimulation and to clarify its characteristics.MethodsUsing a 132-channel magnetoneurography system with a superconducting quantum interference device, cervical MSG measurements were obtained for 10 healthy volunteers after stimulation of the ulnar nerve at the elbow and the wrist, and neural current distribution was calculated and superimposed on the cervical X-ray images.ResultsNeuromagnetic signals were obtained in all participants after applying the stimulus artifact removal algorithm. The measured magnetic field intensity after elbow stimulation was about twice that after wrist stimulation. Calculated neural currents flowed into the intervertebral foramina at C6/7 to T1/2 and propagated cranially along the spinal canal. The conduction velocity from the peak latency of inward currents at C5-C7 was 73.4 ± 19.6 m/s.ConclusionsWe successfully obtained MSG measurements after ulnar nerve stimulation. The neural currents flowed into the spinal canal from more caudal segments after ulnar nerve stimulation compared with median nerve stimulation, and these MSG measurements were effective in examining the spinal tracts at C5/6/7.SignificanceThis is the first report on the use of MSG to visualize electrical activity in the cervical spinal cord and nerve root after ulnar nerve stimulation.  相似文献   

13.
《Clinical neurophysiology》2019,130(8):1311-1319
ObjectiveUnder General Anesthesia (GA), age and Burst Suppression (BS) are associated with cognitive postoperative complications, yet how these parameters are related to per-operative EEG and hypnotic doses is unclear. In this prospective study, we address this question comparing age and BS occurrences with a new score (BPTIVA) based on Propofol doses, EEG and alpha-band power spectral densities, evaluated for SEF95 = 8–13 Hz.Methods59 patients (55 [34–67] yr, 67% female) undergoing neuroradiology or orthopedic surgery were included. Total IntraVenous Anesthesia was used for Propofol and analgesics infusion. Cerebral activity was monitored from a frontal electrodes montage EEG.ResultsBPTIVA was inversely correlated with age (Pearson r = −0.78, p < 0.001), and was significantly lower (p < 0.001) when BS occurred during the GA first minutes (induction). Additionally, the age-free BPTIVA score was better associated with BS at induction than age (AUC = 0.94 versus 0.82, p < 0.05).ConclusionWe designed BPTIVA score based on hypnotics and EEG. It was correlated with age yet was better associated to BS occurring during GA induction, the latter being a cerebral fragility sign.SignificanceThis advocate for an approach based on evaluating the cerebral physiological age (« brain age ») to predict postoperative cognitive evolution.  相似文献   

14.
《Clinical neurophysiology》2021,132(8):1850-1858
ObjectiveWe measured the neurophysiological responses of both active and sham transcranial magnetic stimulation (TMS) for both single pulse (SP) and paired pulse (PP; long interval cortical inhibition (LICI)) paradigms using TMS-EEG (electroencephalography).MethodsNineteen healthy subjects received active and sham (coil 90° tilted and touching the scalp) SP and PP TMS over the left dorsolateral prefrontal cortex (DLPFC). We measured excitability through SP TMS and inhibition (i.e., cortical inhibition (CI)) through PP TMS.ResultsCortical excitability indexed by area under the curve (AUC(25-275ms)) was significantly higher in the active compared to sham stimulation (F(1,18) = 43.737, p < 0.001, η2 = 0.708). Moreover, the amplitude of N100-P200 complex was significantly larger (F(1,18) = 9.118, p < 0.01, η2 = 0.336) with active stimulation (10.38 ± 9.576 µV) compared to sham (4.295 ± 2.323 µV). Significant interaction effects were also observed between active and sham stimulation for both the SP and PP (i.e., LICI) cortical responses. Finally, only active stimulation (CI = 0.64 ± 0.23, p < 0.001) resulted in significant cortical inhibition.ConclusionThe significant differences between active and sham stimulation in both excitatory and inhibitory neurophysiological responses showed that active stimulation elicits responses from the cortex that are different from the non-specific effects of sham stimulation.SignificanceOur study reaffirms that TMS-EEG represents an effective tool to evaluate cortical neurophysiology with high fidelity.  相似文献   

15.
《Brain stimulation》2021,14(5):1059-1067
BackgroundThere is still a lack of controlled studies to prove efficacy of thalamic deep brain stimulation for Tourette's Syndrome.ObjectivesIn this controlled trial, we investigated the course of tic severity, comorbidities and quality of life during thalamic stimulation and whether changes in tic severity can be assigned to ongoing compared to sham stimulation.MethodsWe included eight adult patients with medically refractory Tourette's syndrome. Bilateral electrodes were implanted in the centromedian-parafascicular-complex and the nucleus ventro-oralis internus. Tic severity, quality of life and comorbidities were assessed before surgery as well as six and twelve months after. Short randomized, double-blinded sham-controlled crossover sequences with either active or sham stimulation were implemented at both six- and twelve-months’ assessments. The primary outcome measurement was the difference in the Yale Global Tic Severity Scale tic score between active and sham stimulation. Adverse events were systematically surveyed for all patients to evaluate safety.ResultsActive stimulation resulted in significantly higher tic reductions than sham stimulation (F = 79.5; p = 0.001). Overall quality of life and comorbidities improved significantly in the open-label-phase. Over the course of the trial two severe adverse events occurred that were resolved without sequelae.ConclusionOur results provide evidence that thalamic stimulation is effective in improving tic severity and overall quality of life. Crucially, the reduction of tic severity was primarily driven by active stimulation. Further research may focus on improving stimulation protocols and refining patient selection to improve efficacy and safety of deep brain stimulation for Tourette's Syndrome.  相似文献   

16.
《Clinical neurophysiology》2021,132(10):2510-2518
ObjectiveWe demonstrate the advantages and safety of long, intraorbitally-placed needle electrodes, compared to standard-length subdermal electrodes, when recording lateral rectus electromyography (EMG) during intracranial surgeries.MethodsInsulated 25 mm and uninsulated 13 mm needle electrodes, aimed at the lateral rectus muscle, were placed in parallel during 10 intracranial surgeries, examining spontaneous and stimulation-induced EMG activities. Postoperative complications in these patients were reviewed, alongside additional patients who underwent long electrode placement in the lateral rectus.ResultsIn 40 stimulation-induced recordings from 10 patients, the 25 mm electrodes recorded 6- to 26-fold greater amplitude EMG waveforms than the 13 mm electrodes. The 13 mm electrodes detected greater unwanted volume conduction upon facial nerve stimulation, typically exceeding the amplitude of abducens nerve stimulation. Except for one case with lateral canthus ecchymosis, no clinical or radiographic complications occurred in 36 patients (41 lateral rectus muscles) following needle placement.ConclusionsIntramuscular recordings from long electrode in the lateral rectus offers more reliable EMG monitoring than 13 mm needles, with excellent discrimination between abducens and facial nerve stimulations, and without significant complications from needle placement.SignificanceLong intramuscular electrode within the orbit for lateral rectus EMG recording is practical and reliable for abducens nerve monitoring.  相似文献   

17.
《Clinical neurophysiology》2020,131(12):2887-2898
ObjectiveSingle-pulse navigated transcranial magnetic stimulation (sp-nTMS) is used for presurgical motor mapping in patients with motor-eloquent lesions. However, recently introduced paired-pulse nTMS (pp-nTMS) with biphasic pulses could improve motor mapping.MethodsThirty-four patients (mean age: 56.0 ± 12.7 years, 53.0% high-grade glioma) with motor-eloquent lesions underwent motor mapping of upper extremity representations and nTMS-based tractography of the corticospinal tract (CST) by both sp-nTMS and pp-nTMS with biphasic pulses for the tumor-affected hemisphere before resection.ResultsIn three patients (8.8%), conventional sp-nTMS did not provide motor-positive points, in contrast to pp-nTMS that was capable of generating motor maps in all patients. Good concordance between pp-nTMS and sp-nTMS in the spatial location of motor hotspots and center of gravity (CoG) as well as for CST tracking was observed, with pp-nTMS leading to similar motor map volumes (585.0 ± 667.8 vs. 586.8 ± 204.2 mm3, p = 0.9889) with considerably lower resting motor thresholds (35.0 ± 8.8 vs. 32.8 ± 7.6% of stimulator output, p = 0.0004).ConclusionsPp-nTMS with biphasic pulses may provide motor maps even in highly demanding cases with tumor-affected motor structures or edema, using lower stimulation intensity compared to sp-nTMS.SignificancePp-nTMS with biphasic pulses could replace standardly used sp-nTMS for motor mapping and may be safer due to lower stimulation intensity.  相似文献   

18.
《Brain stimulation》2022,15(1):78-86
BackgroundBrain stimulation is known to affect canonical pathways and proteins involved in memory. However, there are conflicting results on the ability of brain stimulation to improve to memory, which may be due to variations in timing of stimulation.HypothesisWe hypothesized that repetitive transcranial magnetic stimulation (rTMS) given following a learning task and within the time period before retrieval could help improve memory.MethodsWe implanted male B6129SF2/J mice (n = 32) with a cranial attachment to secure the rTMS coil so that the mice could be given consistent stimulation to the frontal area whilst freely moving. Mice then underwent the object recognition test sampling phase and given treatment +3, +24, +48 h following the test. Treatment consisted of 10 min 10 Hz rTMS stimulation (TMS, n = 10), sham treatment (SHAM, n = 11) or a control group which did not do the behavior test or receive rTMS (CONTROL n = 11). At +72 h mice were tested for their exploration of the novel vs familiar object.ResultsAt 72-h's, only the mice which received rTMS had greater exploration of the novel object than the familiar object. We further show that promoting synaptic GluR2 and maintaining synaptic connections in the perirhinal cortex and hippocampal CA1 are important for this effect. In addition, we found evidence that these changes were linked to CAMKII and CREB pathways in hippocampal neurons.ConclusionBy linking the known biological effects of rTMS to memory pathways we provide evidence that rTMS is effective in improving memory when given during the consolidation and maintenance phases.  相似文献   

19.
《Brain stimulation》2021,14(3):622-634
BackgroundtDCS modulates cortical plasticity and has shown potential to improve cognitive/motor functions in healthy young humans. However, age-related alterations of brain structure and functions might require an adaptation of tDCS-parameters to achieve a targeted plasticity effect in older humans and conclusions obtained from young adults might not be directly transferable to older adults. Thus, our study aimed to systematically explore the association between tDCS-parameters and induced aftereffects on motor cortical excitability to determine optimal stimulation protocols for older individuals, as well as to investigate age-related differences of motor cortex plasticity in two different age groups of older adults.Methods32 healthy, volunteers from two different age groups of Young-Old (50–65 years, n = 16) and Old-Old (66–80 years, n = 16) participated in this study. Anodal tDCS was applied over the primary motor cortex, with respective combinations of three intensities (1, 2, and 3 mA) and durations (15, 20, and 30 min), in a sham-controlled cross-over design. Cortical excitability alterations were monitored by single-pulse TMS-induced MEPs until the next day morning after stimulation.ResultsAll active stimulation conditions resulted in a significant enhancement of motor cortical excitability in both age groups. The facilitatory aftereffects of anodal tDCS did not significantly differ between age groups. We observed prolonged plasticity in the late-phase range for two protocols with the highest stimulation intensity (i.e., 3 mA-20 min, 3 mA-30 min).ConclusionsOur study highlights the role of stimulation dosage in tDCS-induced neuroplastic aftereffects in the motor cortex of healthy older adults and delivers crucial information about optimized tDCS protocols in the domain of the primary motor cortex. Our findings might set the grounds for the development of optimal stimulation protocols to reinstate neuroplasticity in different cortical areas and induce long-lasting, functionally relevant plasticity in normal aging and in pathological conditions, which would require however systematic tDCS titration studies over respective target areas.  相似文献   

20.
《Brain stimulation》2020,13(5):1232-1244
BackgroundBrain activity is constrained by and evolves over a network of structural and functional connections. Corticocortical evoked potentials (CCEPs) have been used to measure this connectivity and to discern brain areas involved in both brain function and disease. However, how varying stimulation parameters influences the measured CCEP across brain areas has not been well characterized.ObjectiveTo better understand the factors that influence the amplitude of the CCEPs as well as evoked gamma-band power (70–150 Hz) resulting from single-pulse stimulation via cortical surface and depth electrodes.MethodsCCEPs from 4370 stimulation-response channel pairs were recorded across a range of stimulation parameters and brain regions in 11 patients undergoing long-term monitoring for epilepsy. A generalized mixed-effects model was used to model cortical response amplitudes from 5 to 100 ms post-stimulation.ResultsStimulation levels <5.5 mA generated variable CCEPs with low amplitude and reduced spatial spread. Stimulation at ≥5.5 mA yielded a reliable and maximal CCEP across stimulation-response pairs over all regions. These findings were similar when examining the evoked gamma-band power. The amplitude of both measures was inversely correlated with distance. CCEPs and evoked gamma power were largest when measured in the hippocampus compared with other areas. Larger CCEP size and evoked gamma power were measured within the seizure onset zone compared with outside this zone.ConclusionThese results will help guide future stimulation protocols directed at quantifying network connectivity across cognitive and disease states.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号