目的对CD-3700血液分析仪平均血小板体积(MPV)、血小板压积(PCT)、血小板分布宽度(PDW)无结果的标本,与手工计数结果进行相关性探讨及干扰因素分析。方法将152例CD-3700血液分析仪上检测无MPV、PCT、PDW结果的标本,(1)按血小板的数量分为高值组(血小板>100×109/L),中值组血小板(51~99)×109/L,低值组血小板(31~50)×109/L,极低值组(血小板<30×109/L)。(2)将同批标本用LH750血液分析仪测定,根据有无异常干扰提示分为A组(无异常提示),B组(提示有巨大血小板),C组(提示血小板聚集),D组(提示有小红细胞或细胞碎片干扰)。(3)将同批标本用手工进行计数,各标本组CD-3700结果与手工计数进行相关性分析。结果高值组、中值组与手工计数相关性较好,相关系数分别为0.981、0.961,低值组、极低值组相关性差,分别为0.852、0.406。A组、C组与手工计数相关性好为0.983,0.966,B组、D组相关性差,分别为0.892、0.845。结论在CD-3700血液分析仪上无MPV、PCT、PDW结果的标本,对血小板<50×109/L、有巨大血小板、血小板聚集及细胞干扰的要用手工计数进行纠正,以保证数值的准确性。  相似文献   

2.
目的了解日本SysmexXS-800i全自动血细胞分析仪血小板计数结果的可靠性。方法取300份EDTA-K2抗凝静脉全血标本,根据仪器检测结果中血小板直方图、血小板平均体积(MPV)、红细胞平均体积(MCV)不同,分为正常体积血小板分布组、大血小板组、血小板聚集组和小红细胞干扰组,分别进行仪器法和手工法计数,两组资料作配对t检验。结果正常体积血小板分布仪器法与手工法结果无显著性差异;大血小板组和血小板聚集组的血小板计数仪器法结果假性降低;而小红细胞组血小板计数仪器法结果假性增高。结论正常血小板体积标本SysmexXS-800i五分类血细胞分析仪血小板计数结果准确可靠,但MPV、MCV异常及存在聚集的标本仪器计数血小板不可靠,需手工计数加以纠正。  相似文献   

3.
目的探讨血细胞分析仪计数血小板(PLT)假性减少的原因及处理对策。方法对Beckman LH780自动血细胞分析仪计数PLT100×109/L的351例样本进行手工稀释计数及涂片染色镜检,按血小板直方图类型分组,A组(正常血小板直方图):297例;B组(小血小板直方图):13例;C组(大血小板直方图):11例;D组(血小板聚积直方图):19例;E组(红细胞碎片直方图):11例,对血细胞分析仪计数与手工稀释计数进行比较,并与涂片染色镜检进行相符程度比较。结果①与手工稀释计数比较,A、B组血细胞分析仪PLT计数无显著差异(P0.05);C、D组血细胞分析仪PLT计数减少,有显著性差异(P0.01);E组血细胞分析仪PLT计数增高,有显著性差异(P0.01)。②手工稀释计数比血细胞分析仪计数与涂片染色镜检结果相符程度高。③30例血小板假性减少的样本中,7例EDTA依赖性假性PLT减少(EDTA-PTCP);8例采血不顺造成;4例冷凝集;大血小板及红细胞碎片11例。结论血细胞分析仪计数血小板有可能出现血小板计数假性减少,对血小板直方图异常的样本必须进行手工稀释计数和涂片染色镜检来提高血小板报告的准确性。  相似文献   

4.
血小板异常直方图在判断血小板计数结果中的应用价值   总被引:2,自引:0,他引:2  
目的 探讨血小板异常直方图在判断血小板计数结果中的临床应用价值。方法 利用Sysmex K-4500血细胞分析仪对276例血液标本分析测定,并根据检测结果中血小板直方图、血小板平均体积(MPV)、血小板板分布宽度(PDW)、红细胞平均体积(MCV)和红细胞体积分布宽度(RDW)不同,分为正常血小板组、大血小板组、血小板聚集组、小红细胞干扰组,并对各组血小板进行显微镜手工法计数。结果 正常血小板组两种方法计数结果差异无统计学意义(P〉O.05);大血小板组与血小板聚集组两种方法计数结果差异有统计学意义(P〈O.01),仪器法结果偏低;小红细胞干扰组两种方法计数结果差异有统计学意义(P〈O.01),仪器法偏高。结论 对于血小板直方图异常的标本应分析原因,重留标本复查或手工法计数进行纠正,为临床提供可靠检验数据。  相似文献   

5.
目的采用Sysmex XT4000-i全自动血细胞分析仪检测血小板,探讨小红细胞对其测定结果的影响。方法采集2015年10月~2017年9月来本院就诊的210例患者的血液标本。根据红细胞平均体积大小(MCV)分为A、B、C组,将C组患者按照红细胞分布宽度是否在正常范围内分为2组。分别采用手工检测及仪器检测法对每组血液样本中的血小板进行测定。结果 A组与B组血液标本采用仪器检测法的血小板计数均高于手工检测法(P 0.05),C组血液标本的差异无统计学意义(P0.05)。RDW异常组仪器检测法检测的血小板计数高于手工检测法(P 0.05),两种方法对检测RDW正常组血小板计数的差异无统计学意义(P0.05)。结论小红细胞可对全自动血细胞分析仪Sysmex XT-4000i检测的血小板计数产生影响。  相似文献   

6.
目的:分析手工计数和全自动五分类血球计数仪计数地中海贫血患者外周血血小板数结果的差异。方法:地中海贫血患者60例,采集外周血,分别以SF-3000型全自动五分类血球分析仪及传统手工计数两种不同方法测定血小板数,观察不同贫血程度患者两种方法测定血小板数的差异;同时每份标本都制作一张涂片,瑞氏-吉姆萨染色后,油镜下观察血小板分布情况、血小板形态及大小,并且同时观察成熟红细胞大小及形态。结果:血细胞分析仪计数地中海贫血患者的血小板数,高于传统的手工计数方法计数的结果;轻度贫血患者血细胞分析仪及手工方法计数血小板数分别为(257.35±46.7)×109/L和(220±46.93)×109/L,两种方法测定血小板数差异有显著性意义(P<0.01),中度贫血患者血细胞分析仪及手工方法计数血小板数分别为(353.42±56.05)×109/L和(233.79±51.88)×109/L,统计学分析差异有非常显著性意义(P<0.001),重度贫血患者血细胞分析仪及手工方法计数血小板数分别为(391.63±52.18)×109/L和(230.88±46.77)×109/L,差异有非常显著性意义(P<0.001);而正常对照组两种方法计数血小板数分别为(211±43.05)×109/L和(206.49±41.48)×109/L,统计学分析差异无显著性意义(P>0.05)。结论:SF-3000型全自动五分类血球计数仪检测外周血血小板数高于手工计数方法计数,可能由于仪器不能识别与血小板体积相当大小的红细胞碎片、小红细胞等,导致地中海贫血患者血样中血小板仪器测定结果假性偏高。  相似文献   

7.
目的探讨COULTER 5Diff ACT血细胞分析仪测定地中海贫血患者血小板计数假性升高的影响因素。方法采用COULTER 5Diff ACT血细胞分析仪和传统的显微镜计数方法测定血小板,对两种方法结果作配对t检验。同时每个样本制作一张血片进行瑞氏染色。结果血液分析仪检测地中海贫血患者血小板的结果均比显微镜直接计数的结果偏高,当红细胞体积MCV<65fl时,血细胞分析仪和手工计数法结果有非常显著差异。结论小红细胞和红细胞碎片越多,血小板计数假性增高越明显。COULTER 5Diff ACT血球计数仪检测地中海贫血患者血小板假性升高,是由于小红细胞、红细胞碎片等干扰导致。  相似文献   

8.
目的:分析MEK-7222型全自动血细胞分析仪计数血小板的影响因素。方法:使用MEK-7222型全自动血细胞分析仪在不同条件下对血小板进行测定,并在血小板直方图出现异常时采用手工镜检法计数,两者作对比分析。结果:采用MEK-7222型全自动血细胞分析仪测定血小板,放置10min血小板数显著高于即刻血小板数(P<0.05),之后10min^4h血小板数无显著性变化(P>0.05),放置8h后,血小板数显著低于放置10min血小板数(P<0.05)。采用手工镜检法测定血小板,即刻血小板数与放置10min^4h血小板数无显著性变化(P>0.05),放置8h后血小板数显著降低(P<0.05)。平均红细胞体积(MCV)>70fl时,血细胞分析仪与镜检法血小板计数结果比较,差异无统计学意义(P>0.05);MCV<70fl时,血细胞分析仪血小板计数显著高于镜检法计数(P<0.05)。结论:MEK-7222型全自动血细胞分析仪计数血小板的准确性与标本放置时间、平均红细胞体积的大小有关,必要时可进行重新采血或手工计数。  相似文献   

9.
目的研究小红细胞对血细胞分析仪血小板计数的影响。方法从日常检测的住院病人标本中,选择MCV<65fl的标本32例,MCV在65~70 fl的标本59例,MCV及RDW均正常的标本30例,分别在K-1000血细胞分析仪、CELL-DYN3700血细胞分析仪、CELL-DYN1700血细胞分析仪分析的同时,每份标本人工显微镜计数二次取均值统计,将结果进行配对资料t检验。结果MCV及RDW均正常的标本各仪器与镜检法及各仪器之间血小板计数结果无显著性差异;MCV在65~70 fl之间时,K-1000及CD-3700血细胞分析仪与镜检法之间血小板计数结果无显著性差异,CD-1700与镜检法之间血小板计数结果有显著性差异;MCV<65 fl时CD-3700血细胞分析仪血小板计数与手工法之间无显著性差异,K-1000及CD-1700血细胞分析仪与手工法血小板计数之间有显著性差异。结论在使用CD-1700血细胞分析仪测定血小板计数时,对MCV<70 fl的标本我们应通过人工镜检复查血小板计数结果;在使用K-1000血细胞分析仪时,对MCV小于65fl的标本以及MCV在65~70 fl之间而RDW明显增大且其血小板直方图明显异常的标本应手工复查血小板计数结果。  相似文献   

10.
目的:探讨XS1000i血细胞分析仪部分血小板参数缺失时小红细胞/裂红细胞对血小板计数的影响。方法对XS1000i血细胞分析仪分析后MCV100×109/L时,XS1000i与PENTRA120Retic、显微镜计数血小板的差异有统计学意义(P0.01);当MCV分别为70-80fl,60-70fl,〈60fl时,XS1000i均高于显微镜计数血小板的结果,差异有统计学意义(P〈0.01)。显微镜检查结果发现:101例标本均检出小红细胞或(和)裂红细胞,其中60例伴有大血小板或(和)巨血小板,4例伴有大血小板和血小板聚集。结论对于电阻抗血细胞分析仪,当MCV〈80fl且部分血小板参数缺失时的标本应用显微镜或ICSH推荐的参考方法计数血小板,同时染色镜检异常血细胞的形态、数量及分布。  相似文献   

11.
目的评价SYSMEX XE-5000全自动血细胞分析仪对血小板(PLT)检测结果的可靠性。方法取257份乙二胺四乙酸二钾(EDTA-K2)抗凝静脉全血标本,使用鞘流电阻抗法(impedance,PLT-I)进行血小板检测,根据血小板直方图、血小板平均体积(MPV)、红细胞平均体积(MCV)及血涂片法复查,按不同形态分组,分为正常血小板体积组、大血小板组、小红细胞组,分别用荧光法(optical,PLT-O)与显微镜目测法(microscopic,PLT-M)作对比试验。以及另取30份健康体检者的EDTA-K2抗凝静脉全血标本做红细胞碎片干扰试验,运用SPSS16.0及Excel对相关数据进行统计分析。结果正常体积血小板分布组3种方法之间结果无统计学差异;大血小板组PLT-I结果假性降低,PLT-I与PLT-M法结果差异有统计学意义,PLT-O与PLT-M法结果差异无统计学意义;小红细胞组PLT-I结果假性增高,PLT-I与PLT-M法结果差异有统计学意义,PLT-O与PLT-M法结果差异无统计学意义;RBC碎片干扰试验中,PLT-O对红细胞碎片显示出较强的抗干扰能力。结论正常血小板体积标本SYS-MEX XE-5000全自动血细胞分析仪常规使用PLT-I血小板计数结果正确可靠,但血小板直方图、MPV、MCV异常时标本仪器计数血小板不可靠,需与PLT-O或显微镜手工计数法相结合加以纠正。  相似文献   

12.
脑梗死患者血小板参数的水平观察和初步分析   总被引:3,自引:0,他引:3  
目的探讨脑梗死与血小板各参数的关系。方法采用ABXPentrol-120型全自动五分类血细胞分析仪同时对66例脑梗死患者和50例健康对照者以及60例脑出血患者进行血小板计数(PLT)、血小板平均体积(MPV)、血小板分布宽度(PDw)、血小板压积(PCT)、大血小板比率(PLCR)测定。结果脑梗死患者MPV、PDW、PCT、P-LCR均明显高于健康对照组,差异有统计学意义(P〈0.01);脑梗死组MPV、PDW、P-LCR比脑出血组明显增高,差异有统计学意义(P〈0.01);且MPV空腹血糖呈正相关,差异有统计学意义(r=0.55,P〈0.01)。结论观察脑梗死患者的MPV、PDW、P—LCR值,可以为脑梗死的初步诊断和鉴别诊断提供线索。  相似文献   

13.
The influence of various hematology analyzers on component platelet counts   总被引:2,自引:0,他引:2  
Hematology analyzers designed to count platelets in samples of whole blood are used to enumerate the total number of platelets in components prepared for transfusion. This report addresses the issue of variability in platelet counts obtained with different models of hematology analyzers. The influence of a common calibration procedure, involving one level of porcine platelets, on the extent of variability was also evaluated. Identical sets of samples of simulated and apheresis-derived human platelets were counted by multiple laboratories in 3 separate studies. In the first 2 exercises, 7 samples of both porcine platelets and modified goat erythrocytes with targeted platelets counts from 0.2 to 4.0 x 10(12)/L were counted without prior dilution. In both exercises, the samples were counted multiple times after routine calibration using instructions provided by the manufacturers of the various hematology analyzers used. In the second exercise, the samples were recounted after the hematology analyzers were recalibrated with a common calibrant consisting of porcine platelets at a targeted concentration of 0.5 x 10(12)/L. In the first and second exercises, 20 and 18 hematology analyzers were used, respectively. In the third exercise, 6 samples prepared from a single unit of apheresis platelets with targeted counts from 0.2 to 1.64 x 10(12)/L were shipped by an overnight courier and counted in triplicate on the day of arrival. Eleven hematology analyzers were used. The influence of recalibration was evaluated statistically by using the 95% prediction interval for the mean of a future set of observations. The platelet counts measured with a specific type of hematology analyzer provided the data to calculate the 95% prediction interval. With routine calibration, a wide variability in platelet counts was observed with all levels of both simulated and apheresis-derived human platelets. For example, with porcine platelets at a targeted level of 0.4 x 10 (12)/L, the platelet counts ranged from 0.31 to 0.47 x 10(12)/L. Recalibration reduced the extent of variability observed with all levels of simulated and apheresis-derived human platelets by increasing the observed platelet counts determined with a subset of hematology analyzers that produced platelet counts in the lower portion of the range. With recalibration, the mean platelet counts obtained with most hematology analyzers, especially with samples having targeted platelet levels no greater than 1.0 x 10(12)/L, were within or near the 95% prediction interval determined with the instruments that provided the highest platelet counts with routine calibration. With recalibration, the reproducibility of the platelet counts was considered to be good for all hematology analyzers with all levels of simulated and apheresis-derived human platelets for most of the instruments. The coefficient of variance did not exceed 6%, with most of the values ranging from 1% to 3%. This study therefore found that the platelet counts of platelet concentrates can be markedly influenced by the type of hematology analyzer used. A common calibration procedure designed specifically for the range of platelet counts in platelet products may be beneficial considering that many different hematology analyzers are being used to count platelets.  相似文献   

14.
目的探讨血小板新型参数——平均血小板内容物浓度(MPC)、平均血小板内容物含量(MPM)、大血小板(L-PLT)等在(CHD)患者中的变化及其临床意义。方法根据CHD的诊断标准及冠状动脉造影结果,选取CHD患者92例和正常对照98名,采用德国Bayer公司生产的ADVIA120血液分析仪测定血小板新型参数MPC、MPM、L-PLT及原有血小板参数血小板数(PLT)、平均血小板体积(MPV)、血小板分布宽度(PDW),并用统计学方法(t检验)对其数据进行分析。结果CHD患者血中PLT明显低于正常对照组(P<0.01),而MPV、PDW均明显高于正常对照组(P<0.05),且MPC、MPM、L-PLT均明显高于正常对照组(P<0.05)。结论血小板新型参数MPC、MPM、L-PLT联合血小板原有参数PLT、MPV、PDW在辅助诊断CHD中有一定的临床价值。  相似文献   

15.
目的:单纯大血小板如何影响电阻抗法和光学法血小板计数的差异,为光学法血小板计数的合理应用和有效提高血小板计数的准确性提供支持。方法采用 Sysmex-XE5000全自动血液分析仪电阻抗法和光学法对132例红细胞参数正常的血常规标本进行研究分析,按照 P-LCR 分为大血小板组和正常血小板组。采用非配对 t 检验比较两组间的红细胞参数和血小板参数,采用配对 t 检验比较组内电阻抗法和光学法血小板计数结果。结果两组血小板参数存在极显著差异,大血小板组的 P-LCR、MPV、PDW 和 IPF%均明显高于正常血小板组,而红细胞参数无明显差异。大血小板组电阻抗法和光学法血小板计数差异有统计学意义(P <0.05),电阻抗法计数结果偏低,而正常血小板组则无明显差异。结论大血小板比率升高与未成熟血小板的增加有关。电阻抗法仅根据颗粒大小进行区分,容易将体积较大的大血小板排除,造成血小板计数减低。因此,当大血小板比率升高时,应采用光学法进行血小板计数,避免电阻抗法引起的假性减低。  相似文献   

16.
目的 探讨血小板聚集体计数在真性和乙二胺四乙酸(EDTA)依赖性假性血小板减少(EDTA-PTCP)鉴别中的意义.方法 通过血细胞分析仪(简称仪器法)分析65份EDTA抗凝PLT减少标本(包括15份EDTA-PTCP标本及50份随机抽取的真性血小板减少标本)和50份PLT正常标本的血小板聚集体计数.通过更换柠檬酸盐抗凝剂和人工镜枪法(简称人工法)对仪器法检测PLT减少的标本进行PLT和血小板形态学复核,并比较分析真性和假性血小板减少在常规EDTA抗凝和柠檬酸盐抗凝2种情况下血小板聚集体计数的异同.结果 65份仪器法检测PLT减少的标本,PLT平均为(48±11)×109/L.其中50份真性血小板减少标本仪器法PLT平均为(48±10)×109/L,血小板聚集体计数为86±15;人工法PLT平均为(46±11)×109/L,镜检未发现血小板聚集现象;PLT在仪器法和人工法间差异无统计学意义(t=-1.26,P0.05).另外15份EDTA-FIEP标本,EDTA抗凝后仪器法PLT平均为(48±12)×109/L,血小板聚集体计数明显升高,平均为840±184;人工法PLT减少不明显,但血小板聚集明显,因此未能得到人工法PLT结果;采用柠檬酸盐抗凝后,仪器法PLT和人工法PLT均较前明显升高,分别为(141±13)×109/L和(134±17)×109/L,差异无统计学意义(t=-1.29,P0.05);血小板聚集体计数较前明显减少,平均为75±12,EDTA抗凝法与之比较差异有统计学意义(t=-6.82,P<0.001);镜下未见血小板聚集现象.结论 血小板聚集体计数有望成为监测血小板聚集的有用的临床指标,可用于判断由于血小板聚集引起的血细胞分析仪计数的假性血小板减少.  相似文献   

17.
李霞 《检验医学与临床》2013,10(9):1065-1066
目的探讨冠心病患者血小板参数变化的临床意义。方法采用深圳迈瑞BC5800血细胞分析仪测定60例冠心病患者和50例健康对照者外周血中血小板计数(PLT)、血小板平均体积(MPV)、血小板体积分布宽度(PDW)和大血小板比率(P-LCR),并进行统计分析。结果冠心病患者与健康对照组的PLT、MPV、PDW及P-LCR比较,差异均有统计学意义(P<0.05),其中MPV、PDW和P-LCR明显高于健康对照组,而PLT则明显低于健康对照组。结论临床上动态监测冠心病患者的血小板参数变化,对冠心病的预防、诊治及预后有一定的参考意义。  相似文献   

18.
目的探讨Sysmex XE-2100全自动血细胞分析仪计数有核红细胞的准确性。方法应用Sysmex XE-2100全自动血细胞分析仪筛查有核红细胞阳性的69例标本,用显微镜计数其外周血有核红细胞数量,比较血细胞计数及白细胞分类情况。结果 Sysmex XE-2100与显微镜计数法计数外周血有核红细胞数量有极好的相关性(r=0.992),2种方法计数结果的差异无统计学意义(P〉0.05)。采用有核红细胞计数法,白细胞数较去除有核红细胞前减低(t检验,P〈0.05),且淋巴细胞比例明显减低,而红细胞、血红蛋白及血小板均无明显变化(P〉0.05)。结论 Sysmex XE-2100全自动血细胞分析仪可灵敏、准确、快速地自动计数外周血有核红细胞,有效避免有核红细胞对白细胞总数及分类的干扰。  相似文献   

19.
目的出现血小板直方图分布异常时,仪器与手工镜检血小板计数的比较。方法选择Sysmex XT-2000i检测的血小板直方图分布异常样本127例,其中红细胞MCV<70fl的有50例,红细胞MCV>70fl的有55例,所有样本均用手工镜检计数。结果无论MCV<70n还是MCV>70fl,仪器与手工计数血小板均存在显著性差异。当MCV<70fl时,仪器计数高于手工计数值;当MCV>70fl时,仪器计数小于手工计数值。结论Sysmex XT-2000i在出现血小板直方图分布异常时,需用手工计数进行纠正以减少误诊。  相似文献   