Analysis of bromate and bromide in drinking water by ion chromatography-inductively coupled plasma mass spectrometry |
| |
Authors: | HAN Mei JIA Na LI Ke ZHAO Guo-xing LIU Bing-bing LIU Sheng-hua LIU Jie |
| |
Affiliation: | 1Institute of Hydrogeology and Environmental Geology, Zhengding, Hebei 050803, China |
| |
Abstract: | A method for the detection of bromate and bromide in drinking water by ion chromatography-inductively coupled plasma mass spectrometry (IC-ICP-MS) was developed. The optimized conditions of IC including pH and concentration of the effluent were studied. The results showed that the above two species of bromine were baseline separated within nine minutes under the optimized conditions. The detection limits (S/N=3) of bromate and bromide were 0.23 and 0.12 μg/L, respectively. The RSD (n=6) of the peak areas was 1.2%-3.5%. The method has been successfully applied to the determination of the type bromide in drinking water samples. The recoveries were 95%-109%. The method can be used for the regular analysis of bromate and bromide in real drinking water samples. |
| |
Keywords: | Ion chromatography (IC) Inductively coupled plasma mass spectrometry (ICP- MS) Analysis Bromate Bromide |
|