首页 | 官方网站   微博 | 高级检索  
     

基于互相关分析的低雷诺数涡街流量计设计
引用本文:舒张平,徐科军,邵春莉.基于互相关分析的低雷诺数涡街流量计设计[J].电子测量与仪器学报,2016,30(12):1974-1981.
作者姓名:舒张平  徐科军  邵春莉
作者单位:1. 合肥工业大学自动化研究所 合肥 230009;2. 合肥工业大学自动化研究所 合肥 230009;工业自动化安徽省工程技术研究中心 合肥 230009
摘    要:针对常规涡街流量计难以测量雷诺数在5 000~20 000内流量的问题,研制测量低雷诺数流量的涡街流量计,以扩展量程比。重新设计涡街流量计一次仪表,以满足互相关分析的要求。充分利用两个压电传感器输出信号的相似性,采用互相关分析方法,实现低雷诺数流量的测量。提出一种基于互相关分析快速计算时延的方法,保证仪表的实时性。采用三次样条插值的方法,大大减小较低的采样频率对延迟时间测量精度的影响。以低功耗单片机MSP430F6459为核心,研制成功低功耗、两线制涡街流量变送器。水流量标定结果表明,该涡街流量计量程下限所对应的雷诺数为6 649,测量精度为1级。

关 键 词:低雷诺数涡街流量计  互相关分析  快速计算时延  三次样条插值  低功耗

Design of cross correlation based vortex flowmeter for low Reynolds number flow
Shu Zhangping,Xu Kejun and Shao Chunli.Design of cross correlation based vortex flowmeter for low Reynolds number flow[J].Journal of Electronic Measurement and Instrument,2016,30(12):1974-1981.
Authors:Shu Zhangping  Xu Kejun and Shao Chunli
Affiliation:Institute of Automation, Hefei University of Technology, Hefei 230009, China,1. Institute of Automation, Hefei University of Technology, Hefei 230009, China; 2. Engineering Technology Research Center of Industrial Automation, Hefei 230009, China and Institute of Automation, Hefei University of Technology, Hefei 230009, China
Abstract:Aiming at the problem that conversional vortex flowmeter cannot measure the flow whose Reynolds number in the range of 5 000~20 000, a vortex flowmeter is developed to measure low Reynolds number flow and extend the turndown ratio.The primary instrument of vortex flowmeter is redesigned based on cross-correlation analysis.By making full use of the similarity of two piezoelectric sensor output signals, cross-correlation analysis method is used to measure low Reynolds number flow.A fast time-delay calculation method based on cross-correlation analysis is proposed to ensure real-time measurement.The cubic spline interpolation method is utilized to weaken the impact of lower sampling frequency on the measurement accuracy of the time-delay.A vortex flow transmitter with the operational mode of low power consumption and two-wire is successfully developed using a microcontroller of MSP430F6459 as the core.The calibration results of water flow show that the flowmeter can measure lower flow with its Reynolds number down to 6 649, and possesses the measurement accuracy of 1.0%.
Keywords:vortex flowmeter for low Reynolds  cross-correlation  fast calculation delay  cubic spline interpolation  low power consumption
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《电子测量与仪器学报》浏览原始摘要信息
点击此处可从《电子测量与仪器学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号