R134a/R23-DMF溶液气泡泵输送性能实验
引用本文:王勤,刘轶伦,卢炜,王世宽,何巍,郝楠,张绍志.R134a/R23-DMF溶液气泡泵输送性能实验[J].化工学报,2018,69(Z2):116-122.
作者姓名:王勤  刘轶伦  卢炜  王世宽  何巍  郝楠  张绍志
作者单位:浙江大学制冷与低温研究所, 浙江省制冷与低温技术重点实验室, 浙江 杭州 310027
基金项目:国家重点研发计划项目(2016YFB0901404)。
摘    要:搭建了气泡泵输送性能实验装置,对提升管管径为6、8、12 mm的气泡泵输送不同R134a/R23-DMF浓度溶液的性能进行实验研究。结果表明,在相同制冷剂浓度情况下,三种管径气泡泵的气相流量随着输入功率的增加均呈线性增加趋势,液气比随着气相流量的增加均呈现反向趋势,发生温度随着输入功率增加而线性升高,而输入功率对于系统压力的影响较小。在不同制冷剂浓度情况下,R134a/R23浓度对液气比的影响不明显,但对系统压力影响很大,R134a/R23浓度的增加使得发生温度有微小的升高。8 mm管径气泡泵液气比和稀溶液流量变化幅度居中,而气相流量变化范围最宽,发生温度最低,比较适合用于扩散吸收制冷系统。这些实验结果对扩散吸收制冷系统的气泡泵设计具有重要参考价值。

收稿时间:2018-10-08
修稿时间:2018-10-14

Experiment on transport performance of bubble pumps with R134a/R23-DMF solutions
WANG Qin,LIU Yilun,LU Wei,WANG Shikuan,HE Wei,HAO Nan,ZHANG Shaozhi.Experiment on transport performance of bubble pumps with R134a/R23-DMF solutions[J].Journal of Chemical Industry and Engineering(China),2018,69(Z2):116-122.
Authors:WANG Qin  LIU Yilun  LU Wei  WANG Shikuan  HE Wei  HAO Nan  ZHANG Shaozhi
Affiliation:Key Laboratory of Refrigeration and Cryogenic Technology of Zhejiang Province, Institute of Refrigeration and Cryogenics, Zhejiang University, Hangzhou 310027, Zhejiang, China
Abstract:An experimental rig was built and researches on the transport performance of bubble pumps with R134a/R23-DMF solutions and three lifting tubes of different inner diameters (6 mm, 8 mm and 12 mm) were conducted. On the same concentration of solutions, the results showed the gas mass flow rate and the generating temperature increased approximately linearly with the increase of the heat input, the pumping ratio decreased approximately reversely with the increase of the gas mass flow rate, and the heat input had slight effect on system pressure. The concentrations of solutions had slight effect on the pumping ratio and generating temperature, but it had obvious effect on system pressure. The pumping ratio of the bubble pump and the poor R134a/R23 solution mass flow rate with lifting tube of 8 mm inner diameter has medium variation range compared with those of 6 mm and 12 mm lifting tubes, but the range of the gas mass flow rate was the widest and the generating temperature was the lowest. It showed that the bubble pump with lifting tube of 8 mm inner diameter was appropriate for the diffusion absorption refrigerator. The experimental results will be helpful to the design of bubble pumps for the diffusion absorption refrigerator.