首页 | 官方网站   微博 | 高级检索  
     


A proposed structural design method considering fluid viscous damper degradations
Authors:Hossein Ataei  Kamiar Kalbasi Anaraki
Affiliation:Civil and Environmental Engineering, Link Hall 151, Syracuse University, Syracuse, New York, USA
Abstract:The purpose of this study is to perform a seismic assessment of the moment resistant steel structures enhanced with viscous dampers where the dampers are degraded due to possible leak of viscous fluid. This paper proposes a design procedure based on corrected response spectrums as a result of seismic assessments based on nonlinear time series analyses on three‐, five‐, and seven‐story steel frame structures denoted as “generic structures.” The proposed design procedure is a seismic displacement‐based design methodology for buildings with viscous dampers as passive energy dissipation systems. Prior literature on these types of structures often overlook the viscous dampers degradation due to the fluid leak. In this paper, in order to study these effects, a target displacement is specified at first and the lateral forces and required stiffness are obtained. The effectiveness of the proposed procedure is verified with the collapse fragility curves of the generic structures according to the ASCE 7‐10 and displacement‐based design methodology. The results show that the structures designed based on proposed procedure demonstrate acceptable performance with degrading dampers.
Keywords:fluid viscous damper  degraded viscous damper  leaked viscous damper  DDBD  passive structural control  seismic assessment
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号