Quasi-Z Source Inverter Control of PV Grid-Connected Based on Fuzzy PCI |
| |
Authors: | Tao Hou Chen-Yang Zhang Hong-Xia Niu |
| |
Affiliation: | 1. School of Automation and Electrical Engineering, Lanzhou Jiaotong University, Lanzhou, 730070, China;2. Automatic Control Research Institute, Lanzhou Jiaotong University, Lanzhou, 730070, China |
| |
Abstract: | The photovoltaic grid-connected inverter is an important interface between the photovoltaic power generation system and power grid. Its high-quality operation is directly related to the output power quality of the power grid. In order to further optimize the control effect of the quasi-Z source grid-connected photovoltaic inverter, a fuzzy proportional complex integral control (PCI) method is proposed for the current internal loop control. This method can eliminate the steady-state error, and has the characteristic of zero steady-state error adjustment for the AC disturbance signal of a specific frequency. The inductance-capacitance-inductance (LCL) filter is adopted in the grid-connected circuit, and the feedback capacitive current is taken as the control variable of the inner loop to form the active damping control method, which can not only effectively suppress the resonance of the LCL circuit, but also significantly inhibit the high-order harmonics in the grid-connected current. Finally, a system simulation model is built in MATLAB/Simulink to verify the superiority and effectiveness of the proposed method. |
| |
Keywords: | Frequency of harmonic distortion fuzzy proportional complex integral inductance-capacitance-inductance (LCL) filtering circuit photovoltaic grid-connection quasi-Z source inverter |
本文献已被 ScienceDirect 等数据库收录! |
| 点击此处可从《电子科技学刊:英文版》浏览原始摘要信息 |
|
点击此处可从《电子科技学刊:英文版》下载全文 |
|