首页 | 官方网站   微博 | 高级检索  
     

基于无功判定法的Crowbar保护电路退出控制
引用本文:李鸿儒,金炜东,胡立锦,赵炯,唐俊.基于无功判定法的Crowbar保护电路退出控制[J].电力系统保护与控制,2012(15):99-103.
作者姓名:李鸿儒  金炜东  胡立锦  赵炯  唐俊
作者单位:1. 西南交通大学电气工程学院,四川 成都 610031
2. 新疆大学电气工程学院,新疆 乌鲁木齐 830047
基金项目:国家自然科学基金(60971103);中央高校基本科研业务费专项资金~~
摘    要:"并网难"已成为风电发展的瓶颈,而低电压穿越(Low Voltage Ride Through,LVRT)是风电并网中的核心技术,目前主要采用Crowbar保护电路实现风电机组在大干扰下也具有LVRT能力,而Crowbar电路退出时间对电网故障恢复有很大的影响。根据我国风电大规模远距离的特点,在DIgSILENT中建立了双馈风力发电机组(Doubly-Fed Induction Generator,DFIG)的动态模型,并经过远距离输电线与IEEE9节点电力系统相连,仿真分析了DFIG在各种短路故障条件下的运行特性,提出一种基于无功功率判定的Crowbar退出控制方法,能实现Crowbar电路在故障切除后立刻退出,提高了DFIG的LVRT能力。

关 键 词:风力发电  低电压穿越  双馈感应发电机  Crowbar保护电路  无功判定法

Crowbar protection circuit quitting control based on the reactive power judgment
LI Hong-ru,JIN Wei-dong,HU Li-jin,ZHAO Jiong,TANG Jun.Crowbar protection circuit quitting control based on the reactive power judgment[J].Power System Protection and Control,2012(15):99-103.
Authors:LI Hong-ru  JIN Wei-dong  HU Li-jin  ZHAO Jiong  TANG Jun
Affiliation:1(1.School of Electrical Engineering,Southwest Jiaotong University,Chengdu 610031,China;2.College of Electrical Engineering,Xinjiang University,Urumqi 830047,China)
Abstract:"Difficult grid-connection" has become the bottleneck of wind power generation development.And the low voltage ride through(LVRT) is the core technology of grid-connected wind power generation.At present the Crowbar protection circuit is mainly used to realize the LVRT capability of wind generator under large disturbances.And the quitting time of the Crowbar protection circuit has important effect on electric network fault restoration.According to the characteristics of large scale and long distance of China’s wind power generation,in this paper,a dynamic model of doubly-fed induction generator(DFIG) which is connected with the IEEE9 nodes power system through the long distance transmission line has been established in DIgSILENT.The operational characteristics of DFIG under various short circuit fault conditions are simulated and analyzed.A Crowbar protection circuit quitting control method based on the reactive power judgment is presented,which can realize Crowbar protection circuit quitting immediately after fault clearance and can improve the LVRT capability of DFIG.
Keywords:wind power generation  low voltage ride through(LVRT)  doubly-fed induction generator(DFIG)  Crowbar protection circuit  reactive power judgment
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号